Blinking

Error number

Below is a list of error codes that may appear on the 

display when there is some trouble with the system setting 

or operation.

When the display shows an error code as indicated below, 

contact the number registered in the Remote Controller or 

a nearest authorised installer.

All switches are disabled except 

 

 and 

 .

*

1

The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.

*

2

Only displayed when COOL mode is unlocked (This means when COOL mode is available).

Error No.

Error explanation

H12

Capacity mismatch

H15

Compressor sensor error

H20

Pump error

H21

Water pressure error

H22

Tank sensor 2 error

H23

Refrigerant sensor error

H27

Service valve error

H28

Solar sensor error

H31

Pool sensor error

H36

Buffer tank sensor error

H38

Brand mismatch error

H42

Low pressure protection

H43

Zone 1 sensor error

H44

Zone 2 sensor error

H62

Water 

fl

 ow error

H63

Low pressure sensor error

H64

High pressure sensor error

H65

Deice water circulation error

H67

External thermistor 1 error

H68

External thermistor 2 error

H70

Back-up heater OLP error

H72

Tank sensor 1 error

H74

PCB communication error

H75

Low water temp protection

H76

RC-1 & Indoor communication error

RC-1 & RC-2 communication error 

H90

Indoor-Outdoor communication error

H91

Tank heater OLP error

H95

Voltage connection error

H98

High pressure protection

H99

Indoor freeze prevention

Error No.

Error explanation

F12

Pressure switch activated

F14

Poor compressor rotation

F15

Fan motor lock error

F16

Current protection

F20

Compressor overload protection

F22

Transistor module overload protection

F23

DC peak

F24

Refrigerant cycle error

F25

*

1, 

*

2

 Cool / heat cycle error

F27

Pressure switch error

F29

Low discharge super heat

F30

Water outlet sensor 2 error

F32

RC-1’s internal thermostat error

RC-2’s internal thermostat error

F34

Indoor water heat exchanger leak

F35

External meter communication error

F36

Outdoor ambient sensor error

F37

Water inlet sensor error

F40

Outdoor discharge sensor error

F41

Power factor correction error

F42

Outdoor heat exchanger sensor error

F43

Outdoor defrost sensor error

F45

Water outlet sensor error

F46

Current transformer disconnection

F48

Evaporator outlet sensor error

F49

Bypass outlet sensor error

F50

Water inlet 2 sensor error

F51

Economizer outlet sensor error

F52

Bypass inlet sensor error

F53

Main expansion valve overcurrent protection

F54

Bypass expansion valve overcurrent protection

F95

*

1, 

*

2

 Cooling high pressure error

Troubleshooting

*  Some error code may not be applicable to your model. Consult authorised dealer for clari

fi

 cation.

Содержание WH-ADC0509L3E5B

Страница 1: ...module Tank Model No Indoor Unit WH ADC0509L3E5B Outdoor Unit WH WDG05LE5 WH WDG07LE5 WH WDG09LE5 ENGLISH Before operating the system please read these operating instructions thoroughly and keep them...

Страница 2: ...nstaller 5 Installer setup System setup 32 36 5 1 Optional PCB connectivity 5 2 Zone Sensor 5 3 Heater capacity 5 4 Anti freezing 5 5 DHW capacity 5 6 Base pan heater 5 7 Alternative outdoor sensor 5...

Страница 3: ...ply Indoor Unit Structure of the unit may vary depending on the model Remote Controller Front Plate Tap Note Not recommended to open the Front Plate For authorised dealer specialist use only The illus...

Страница 4: ...een given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall no...

Страница 5: ...check RCCB ELCB operation regularly especially after installation inspection and maintenance RCCB ELCB malfunction may result in electric shock and or fire It is strongly recommended that Install Res...

Страница 6: ...containers or Not immersed in water After a long period of use or use with any combustible equipment aerate the room regularly After a long period of use make sure the installation rack does not dete...

Страница 7: ...thin a system is prohibited Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by...

Страница 8: ...posal and c Able to understand and to apply in practice the requirements in the national legislation regulations and Standards and d Continuously undergo regular and further training to maintain this...

Страница 9: ...se of flammable refrigerants Servicing shall be performed only as recommended by the manufacturer 2 2 Work Prior to beginning work on systems containing flammable refrigerants safety checks are necess...

Страница 10: ...extinguisher adjacent to the charging area 2 5 No ignition sources No person carrying out work in relation to a refrigerating system shall use any sources of ignition in such a manner that it may lea...

Страница 11: ...constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical comp...

Страница 12: ...s NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment Intrinsically safe components do not have to be isolated prior to working on them 4 Repair to...

Страница 13: ...requires brazing all of the refrigerant shall be recovered from the system The precautions in 8 must be followed to remove the refrigerant 8 Removal and evacuation When breaking into the refrigerant...

Страница 14: ...discharging the refrigerant To avoid fire or explosion dissipate static electricity during transfer by grounding and bonding containers and equipment before charging discharging 10 Decommissioning Be...

Страница 15: ...ants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding th...

Страница 16: ...ry cylinder and the relevant Waste Transfer Note arranged Do not mix refrigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be removed ensure that they...

Страница 17: ...tective zone must not extend to adjacent buildings or public traffic areas boundaries of neighbors the public road neighbor s private roads subsidence area depressions pump shafts sewers intakes waste...

Страница 18: ...with white icons 4 Main Menu button For function setup 5 ON OFF button Starts Stops operation 6 Operation indicator Illuminates during operation blinks during alarm When the backlight is off press any...

Страница 19: ...k is installed The direction icons point to the currently active mode Room operation Tank operation Deice operation B Operation icons The status of operation is displayed Icon will not display under o...

Страница 20: ...nth Day Hour Min 12 00 am 2022 1 Select with or how to display the time either 24h or am pm format for example 15 00 or 3 00 pm 2 Press to confirm the selection 3 Use and to select year month day hour...

Страница 21: ...the setting according to the instructions displayed at the bottom of the screen The icons refer to each selection key Quick Menu Force DHW Powerful Quiet Force Heater Weekly Timer Force Defrost Error...

Страница 22: ...f operation mode should change back to the previous memorized status Powerful Select this icon to operate the heating cooling system powerfully Press to confirm your selection The powerful operation s...

Страница 23: ...2 The Quiet mode operates at level 3 Level 3 is the most quiet mode Select this to set a timer for the Quiet mode operation After 1 sec delay Select Yes Select Yes using buttons Select pattern 1 6 Sel...

Страница 24: ...lection The Force Heater mode starts approximately 1 minute after is pressed Force Heater is turned off Force Heater is turned on Note Force Heater is disabled whenever operation is already on and Dis...

Страница 25: ...Select the day s which you wish to edit using buttons If all 6 patterns are not preset this screen will be displayed 1 2 3 4 5 6 1 Select pattern 1 6 2 Set the hour and minutes of the Timer 3 Select O...

Страница 26: ...lock the Remote Controller Press to confirm your selection When the mode has been accepted below screen will be displayed Select Yes The Main Screen will be locked If No is selected the screen will r...

Страница 27: ...p 1 1 Weekly timer Once the weekly timer is set up User can edit from Quick Menu To set up to 6 patterns of operation on a daily basis Disabled if Heat Cool SW is select Yes or if Force Heater is on T...

Страница 28: ...N or OFF ON Do not use the system during sterilization in order to prevent scalding with hot water or overheating of shower Ask an authorised dealer to determine the level of sterilization function fi...

Страница 29: ...0 V and may differ from value measured by precise equipment 2 2 System information Shows all system information in each area Actual system information of 9 items Inlet Outlet Zone 1 Zone 2 Tank Pool C...

Страница 30: ...RC No Confirm 10 34am Mon RC 1 3 2 Touch sound Turns the operation sound ON OFF ON 3 3 LCD contrast Sets the screen contrast 3 3 4 Backlight Sets the duration of screen backlight 1 min 3 5 Backlight i...

Страница 31: ...SCH ITALIANO ESPA OL DANISH SWEDISH NORWEGIAN POLISH CZECH NEDERLANDS T RK E SUOMI MAGYAR SLOVEN INA HRVATSKI LIETUVI PORTUGU S EESTI LATVIE U ROM N SHQIP SLOVEN INA 3 9 Unlock password 4 digit passwo...

Страница 32: ...or 2 zone system Zone After selecting 1 or 2 zone system proceed to the selection of room or swimming pool If the swimming pool is selected the temperature must be selected for T temperature between 0...

Страница 33: ...n heater To select whether or not optional base pan heater is connected Type A The base pan heater activates only during deice operation Type B The base pan heater activates when outdoor ambient tempe...

Страница 34: ...rate during low outdoor temperature Manual 5 17 Defrost signal To turn on defrost signal to stop fan coil during defrost operation If defrost signal set to yes bivalent function will not available to...

Страница 35: ...tion meter is connected It is to measure energy generation of heat pump unit during heating cooling and DHW operation one generation meter system or during heating and cooling only two generation mete...

Страница 36: ...n on Energy Monitor display data displayed on the remote controller is obtained through heat pump s internal calculation If Approx is NOT shown on Energy Monitor display data displayed on the remote c...

Страница 37: ...ntal X axis 2 on vertical Y axis Heat ON Water temp Zone1 Confirm Select 55 C 75 20 20 15 35 C 5 C 15 C Temperature range X axis 20 C 15 C Y axis See below Temperature range for the Y axis input WH WD...

Страница 38: ...ater ON OFF Water temperature for heater ON 4 C Setting of water temperature to turn on from water set temperature Heater ON OFF Water temperature for heater OFF 2 C Setting of water temperature to tu...

Страница 39: ...m is selected temperature set point must input for Zone 2 Zone 1 and Zone 2 will not appear on the display if only 1 zone system T for cooling ON 5 C Set T for cooling ON This setting will not availab...

Страница 40: ...3 functions at a time Floor operation time max 8 00 Maximum time for floor operation in hours and minutes Tank heat up time max 1 00 Maximum time for heating the tank in hours and minutes Tank re heat...

Страница 41: ...w rate max duty and operation ON OFF of the pump Flow rate XX X L min Max Duty 0x40 0xFE Pump ON OFF Air Purge 7 2 Dry concrete To dry the concrete floor walls etc during construction Do not use this...

Страница 42: ...ngle when one remote controller is connected Select Dual when two remote controllers are connected Second remote controller can be used for zone 2 room temperature control Single Selection of one or t...

Страница 43: ...Do not obstruct the air inlet and outlet vents Failure to do so may result in low performance or system breakdown Remove any obstruction to assure the ventilation When it snows clean and remove snow...

Страница 44: ...ses flammable gas may be mixed in so when venting keep ignition sources away and ventilate well User In order to ensure optimal performance of the units user may inspect and clear any obstruction on t...

Страница 45: ...er time to heat up System does not heat up instantly System will take some time to heat up the water if it starts to operate at cold water temperature Backup heater is automatically turned ON when it...

Страница 46: ...H76 RC 1 Indoor communication error RC 1 RC 2 communication error H90 Indoor Outdoor communication error H91 Tank heater OLP error H95 Voltage connection error H98 High pressure protection H99 Indoor...

Страница 47: ...t phone device to prevent miss operation Do not use other remote control communication and operation device not specified by an authorised dealer or specialist Use under the agreement of Terms of Serv...

Страница 48: ...is leaked together with an external ignition source there is a possibility of fire explosion This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service...

Страница 49: ...untry Hotline Phone Number Country Hotline Phone Number Austria 0800 700666 Hungary 36 1 382 60 60 Baltic 46 8 680 26 50 Netherlands 31 0 736402538 Bulgaria 359 2 971 29 69 Norway 47 210 339 99 Croati...

Отзывы: