P-34
PROGRAMMING (MODE 1)
0806#-(0 or 1)#
SLT RINGER FREQUENCY
Changes the ringer frequency of the SLT ring signal.
Set the ringer frequency to either of 20Hz or 25Hz.
0#: 20Hz
1#: 25Hz
0901#-(0, 01-16)#
DSS1 PAIR PORT NUMBER
When DSS1 is connected to the system, it is necessary
to set the DSS1 to pair with one of the extension No., or
not.
When paired with DSS1, set the telephone port number.
0# : Does not use DSS1
(01-16)# : Key Telephone Port Number
0902#-(0, 01-16)#
DSS2 PAIR PORT NUMBER
When DSS2 is connected to the system, it is necessary
to set the DSS2 to pair with one of the extension No., or
not.
When paired with DSS2, set the telephone port number.
0# : Does not use DSS2
(01-16)#: Key Telephone Port Number
1001#-(0000-9999)#
ADMINISTRATOR’S TELEPHONE ID
A telephone which is not set by “Administrator’s
Telephone Setting” of MODE4 Extension Setting can
be temporarily used as an Administrator’s Telephone by
ID code.
To set 4-digit ID code which is necessary to use the
telephone as an Administrator’s Telephone.
0#
: Does not set ID
(0000-9998)#
: ID code
9999#
Clear
: Press FF5 Key
0802#-(0 or 1)#
SLT HOLD BY RECALL KEY
Sets how to hold SLT.
To set the hold mode by Recall operation or Recall and
numbering plan operation:
0#: Hold by Recall
1#: Hold by Recall and numbering plan
REFERENCE : Numbering plans are as follows.
• [5]: Exchange line System Hold or
Intercom Hold
• [6]: Exchange line Exclusive Hold
or Intercom Hold
0803#-(0 or 1)#
SLT EXCHANGE LINE HOLD
An Exchange line call on your single-line telephone
extension can be automatically put on System Hold or
Exclusive Hold.
0#: System Hold
1#: Exclusive Hold
NOTE : This function will be valid only when hold by
Recall (0#) is set in the MODE 1 0802#.
0804#-(0 or 1)#
SLT INTERNAL RING PATTERN
Set which pattern to use for the internal ring signal
(including extension recall ring and doorphone ring).
0805#-(0 or 1)#
SLT EXCHANGE LINE RING PATTERN
Set which pattern to use for the exchange line ring
signal (including extension recall ring and doorphone
ring).
1sec
0#:
1#:
2sec 3sec 4sec 5sec 6sec 7sec 8sec
1sec
0#:
1#:
2sec 3sec 4sec 5sec 6sec 7sec 8sec
Содержание VoiceSonic VB-9411AD