4.2.3 Information about the power supply unit
After connecting the power supply units, make connections to each device.
Note:
R
The VL-PS2410 power supply unit has 6 DC OUT connection terminals. (Use the VL-PS2410 so that the combined
output does not exceed 2.5 A. Check the power consumption of each device for more information.)
R
Other than for VL-MV10 bus-powered main monitors, use the power supply units included with the main monitors
or connect the power cord of the main monitors.
R
VL-MV10 bus-powered main monitors receive power from a lobby station (when using star wiring) or a distributor
(when using bus wiring), and therefore do not need a power supply unit. When using VL-MV10, we recommend
using a VL-PS2410.
Power supply for distributors and wiring for power supply units
In order to start up distributors ((
A
); maximum of 8) that use bus wiring, use either the VL-PS240 or VL-PS2410 power
supply units in one of the following arrangements.
n
Number of operable VL-VM701 (distributors)
Number of connectable distributors
With VL-MV10 main monitor
With other main monitors
Power
supply unit
VL-PS240
(0.6 A
type)
Up to 1 distributor (VL-PS240 can
only be used in systems with 1
distributor)
Up to 4 distributors (for each power
supply unit)
VL-PS2410
(2.5 A
Up to 8 distributors (for each power
supply unit)
Up to 8 distributors (for each power
supply unit)
*1 Connection when using 1 power supply unit: 1st distributor
Connection when using 2 power supply units: 1st distributor and 5th distributor
Example: when a VL-MV10 is connected using 1 VL-PS2410 power supply unit
If the system consists of 1 VL-PS2410 and 5 or more distributors are used, connect wiring from the VL-PS2410 to the
1st and 5th distributors.
#4
#3
#2
#1
#8
#7
#6
#5
1
23