3.  Open the access door on the bottom of the wall mount 

by loosening the screw nearest the mounting plate.

4.  Attach the wires from the wall to the connector provided. 

using the wiring color code chart as a guide.

5.  Once all wiring connections are made, place the wires 

inside the wall mount bracket and close the access door. 
Secure with the screw removed earlier.

CONNECTING THE TRIM RING ASSEMBLY TO THE 

HOUSING TOP:

1.  Open the access door on the bottom of the wall mount by 

loosening the screw nearest the mounting plate.

CARE AND CLEANING OF DOMES:

All RHW75 and RHP75 units include an optically clear 
polycarbonate dome. The dome is an optical device and 
should be handled with extreme care. Leave protective film 
on dome until product is fully assembled and installed. Even 
though the dome is virtually unbreakable, it 

can

 be easily 

scratched.

Clean only with a clean cotton cloth and warm water.

DO NOT use a strong solvent or cleanser!

Access panel

Remove dome by twisting counterclockwise 

until it stops, then pull down

2.  To attach trim ring align pins with keyhole slots and turn 

clockwise about ½" (12mm). Secure (3) screw or use (3) 
security screws and security tool provided.

INSTALLING WALL MOUNT

A wall mount bracket comes standard with this unit, and 
a template is included to use as a guide for mounting the 
bracKet to a wall.

 

1.  Choose the desired location for installation and mark 

the drill holes using the template. Screw (2) bolts (not 
provided) about ¾ of the way into the (2) top holes. Run 
approximately 8 of wiring out of the wall.

2.  The wall mount bracket provided with the FDW7 includes 

a location for conduit entry. If you wish to install conduit to 
the bracket remove the conduit hole plug. Install fitting from 
below the wall mount and secure with conduit nut from 
inside the bracket.

NOTE:

  

Be sure the hardware and the mounting 
surface can support the weight of the 
wall mount bracket plus the weight of the 
housing and drive unit. The load will be 
subjected to vibration from the camera 
motor and wind. 

Содержание VIDEOALARM PODV7CPNS

Страница 1: ...for Before attempting to connect or operate this product please read these instructions completely Installation Instructions Outdoor Dome Housings PODV7CWNS PODV7CPNS Manufactured By 81 IN3090 01 18 07 ...

Страница 2: ...f the installation is intact Failure to comply with the foregoing could result in the unit separating from the support structure and falling with resultant damages or injury to anyone or anything struck by the falling unit UNPACKING Unpackcarefully Electroniccomponentscanbedamaged ifimproperlyhandledordropped Ifanitemappearstohave been damaged in shipment replace it properly in its carton and noti...

Страница 3: ...ely mounted to a supporting structure capable of rigidly holding the weight of the entire unit GENERAL INSTRUCTIONS Tools Required 100 Flat Head Screwdriver Phillips Head Screwdriver PODV7CWNS PODV7CPNS IP Ready Network Housing IP Ready Network Housing with 24Vac input wall mount or pendant mounting heater blowers WV NS202 and camera ASSEMBLING THE UNIT 1 Remove content from all boxes Contents sho...

Страница 4: ...tar washers provided in the packet assembly 1 Twist camera to secure Attach the Camera to the quick release plate Attach safety lanyard to the back of the camera Position the camera as shown below on the quick release plate and twist clockwise Please see Pansonic Operation Manual for additonal details 2 Complete wiring connections Connect the RJ45 network cable to into the network input Complete p...

Страница 5: ... from the 2nd position to the 4th position of the terminal block Be careful not to short between the yellow and green wires 22 250 120 89 65 44 35 29 25 31 19 17 16 14 13 12 20 400 180 141 90 70 56 47 40 34 31 28 25 23 21 20 18 18 600 300 225 130 112 90 75 64 55 50 45 41 37 34 32 30 16 960 480 358 225 179 143 119 102 85 79 71 65 59 55 51 47 14 800 571 350 285 228 190 163 140 126 114 103 95 87 81 7...

Страница 6: ... wall mount bracket 2 Attach the housing coupling Add thread sealing tape NOTE Pipe threads should be clean and rust free Use the Teflon tape included with the housing on the threads Teflon Tape A small roll of Teflon tape is provided with all pendant units 3 Mount the housing assembly to the mounting bracket and housing coupling A safety cable is included with the housing to temporarily hold it w...

Страница 7: ...T use a strong solvent or cleanser Access panel Remove dome by twisting counterclockwise until it stops then pull down 2 To attach trim ring align pins with keyhole slots and turn clockwise about 12mm Secure 3 screw or use 3 security screws and security tool provided INSTALLING WALL MOUNT A wall mount bracket comes standard with this unit and a template is included to use as a guide for mounting t...

Страница 8: ... Exploded View for Replacement Parts 16 18 1 1 2 3 1 19 11 10 6 5 4 7 8 9 2 3 12 1 13 14 15 17 ...

Страница 9: ...PFD040 Upper Bracket Assembly 9 RPRH709 Housing Top 10 RPFD2612 Housing Top Gasket 11 WM10 Wall Mount Bracket Black 12 RPFD080 12VDC Blower Used on 24VAC Units 13 RPNET02 24 to 12DC Power Supply 14 RP FDJV 2000 Power Supply Bracket 15 RPPKPODV 1 spacers set of 4 16 SD0160 Pendent Mount Bracket 17 SD0170 Pendent Housing Coupling 18 RPPKE1125 Electrical Connector Packet 19 RPPKH2100 Housing Hardware...

Страница 10: ... 10 2 000 3 250 R 733 2 132 2 981 1 537 5 500 Mounting Template ...

Отзывы: