manualshive.com logo in svg
background image

ENGLISH

ENGLISH

Thank you for purchasing this Panasonic product.

 

To customer

This Installation Instructions is intended for use by installation personnel. Be sure to employ quali-

fied installation specialists to perform the installation work.

After the installation work is complete, have the installation personnel return this Installation Instructions to 

you, and save it for future use.

When relocating or removing the display unit, give this manual to qualified installation specialists and have 

them perform the procedure.

 

To installation personnel

Read this Installation Instructions thoroughly and then perform the work correctly and safely.

Be sure to read “Safety Precautions” (pages 3 to 5) in particular before performing the installation work. 

After the installation work is complete, return this Installation Instructions to the customer.

 

We shall have no liability for any accidents or damage incurred by installing the product in any 

manner other than as provided in the Installation Instructions, or without using parts specified.

DPQX1351ZA/X1

Installation Instructions

Wall-hanging bracket (Vertical mounting type)  Commercial Use

Model No. 

TY-WK98PV1

Содержание TY-WK98PV1

Страница 1: ...pecialists and have them perform the procedure To installation personnel Read this Installation Instructions thoroughly and then perform the work correctly and safely Be sure to read Safety Precautions pages 3 to 5 in particular before performing the installation work After the installation work is complete return this Installation Instructions to the customer We shall have no liability for any ac...

Страница 2: ...ling the Bracket to Be Attached to the Wall Surface 13 Assembling the Set Mounts to Be Attached to the Display Unit 16 Attaching 18 Attaching the Set Mounts to the Display Unit 18 Attaching the Bracket to the Wall 19 Preparing the Display Unit 21 Installing the Display Unit 22 Wall Mounting Hole Positions and Dimensions Diagram 25 Screw Tightening Torque 26 ...

Страница 3: ...e display unit may drop and may cause damage and injury Include a safety factor when considering the strength of the proposed installation location z zIf strength is not sufficient the display unit may drop and may cause injury Ensure that the installation location is strong enough to support long term use z zIf its strength becomes insufficient over the course of long term use the display may dro...

Страница 4: ...op and may cause damage and injury When removing the display unit also remove the wall hanging bracket z zOtherwise somebody may for example bump into the wall hanging bracket and may cause injury Remove the product from the installation location when it is no longer going to be used z zOtherwise the product may topple over and may cause damage and injury The display unit should be attached and re...

Страница 5: ... material wood steel frame concrete etc of the wall surface to which the wall hanging bracket is to be attached Ensure good air flow so that the equipment ambient temperature does not exceed 40 C 104 F Failure to do this may cause heat to build up inside the display and may cause malfunction Spread a soft blanket or cloth over the floor so that the display and floor will not be marked or scratched...

Страница 6: ...e this when the horizontal pitch is 800 mm 31 5 2 Center base plate 600 1 Use this when the horizontal pitch is 600 mm 23 7 2 Center base plate 500 1 Use this when the horizontal pitch is 500 mm 19 7 2 Center base plate 400 Use this when the horizontal pitch is 400 mm 15 8 2 Spacer plate 2 A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 Product Components 1 Be sure to install the spacer plates If the spacer p...

Страница 7: ...inued Part name Appearance quantity Side base plate 2 Set mount Upper 2 Set mount Lower 2 Countersunk screw M4x6 32 Lock screw M5x200 1 Lock screw M5x70 1 Set mount screw M8x20 4 Set mount screw M6x12 4 A 10 B 1 B 2 C 1 C 2 C 3 C 4 C 5 ...

Страница 8: ...splay unit check the specifications or instruction manual of the corresponding display unit at the following website https panasonic net cns prodisplays download spec_manual Setting installation pitch 400 x 400 Landscape or portrait orientation When viewed from front Unit mm PCS 720 8 28 4 732 6 28 9 Side base plate Base plate upside L A 1 Base plate upside R A 2 A 10 Side base plate A 10 A 8 Cent...

Страница 9: ...Base plate upside L A 1 Base plate upside R A 2 Base plate downside L A 3 Base plate downside R A 4 Side base plate A 10 Side base plate A 10 When viewed from back z zThis surface contacts the wall Side base plate Side base plate Base plate upside R A 10 A 3 A 1 A 10 A 2 A 4 Base plate upside L Base plate downside R Base plate downside L Center base plate 600 A 6 Spacer plate A 9 A 1 1 A 2 1 A 3 1...

Страница 10: ...se plate down side L A 3 Base plate downside R A 4 Center base plate 400 A 8 Side base plate A 10 Side base plate A 10 Base plate upside L A 1 Base plate upside R A 2 When viewed from back z zThis surface contacts the wall Side base plate Side base plate Base plate upside R A 10 A 3 A 1 A 10 A 2 A 4 Base plate upside L Base plate downside R Base plate downside L A 1 1 A 2 1 A 3 1 A 4 1 A 8 2 A 10 ...

Страница 11: ...Base plate upside L A 1 Base plate upside R A 2 Side base plate A 10 Side base plate A 10 Base plate downside L A 3 Base plate downside R A 4 When viewed from back z zThis surface contacts the wall Side base plate Side base plate Base plate upside R A 10 A 3 A 1 A 10 A 2 A 4 Base plate upside L Base plate down side R Base plate down side L Center base plate 800 A 5 Spacer plate A 9 A 1 1 A 2 1 A 3...

Страница 12: ...se plate upside R A 2 Side base plate A 10 Side base plate A 10 Base plate downside R A 4 Base plate downside L A 3 Center base plate 500 A 7 When viewed from back z zThis surface contacts the wall Side base plate Side base plate Base plate upside R A 10 A 3 A 1 A 10 A 2 A 4 Base plate upside L Base plate downside R Base plate downside L Spacer plate A 9 Center base plate 500 A 7 A 1 1 A 2 1 A 3 1...

Страница 13: ...faces for installing the screws have countersinks so that the countersunk screws sit flush with the surface Install the countersunk screws from the surfaces with the countersinks z zThe surfaces with the countersunk screw heads will contact the display unit or wall Installation will not be possible if the countersunk screws are protruding so tighten the countersunk screws until their heads are not...

Страница 14: ...pside L over the right side of the center base plate and fix it in place with three countersunk screws Tightening torque 1 4 to 1 6 N m When center base plate is 800 600 or 500 A C B Base plate down side R A 4 Base plate down side L A 3 Center base plate 800 A 5 600 A 6 500 A 7 Positioning hole Spacer plate A 9 2 Assemble the base plate lower A Place base plate downside R over the left side of the...

Страница 15: ...plate upper over the upper part of the other side base plate and fix it in place with two countersunk screws E Confirm the positions of the holes at the lower part of the side base plate as shown in the figure F Place the left side of the base plate lower over the lower part of the side base plate on the left side and fix it in place with two countersunk screws G Place the right side of the base p...

Страница 16: ...2 Set mount Upper B 1 1 Assemble the set mounts for the display unit A Confirm the positions of the holes in the set mount upper z zThe installation positions differ depending on the display unit installation pitch B Place the set mount lower over the set mount upper and fix it in place with two countersunk screws Tightening torque 1 4 to 1 6 N m Attention z zPlace the set mount lower so that the ...

Страница 17: ... to attach the set mounts lower Set mount Lower B 2 Set mount Upper B 1 Set mount Upper B 1 Set mount Upper B 1 Set mount Lower B 2 Set mount Lower B 2 When installation pitch of display unit is 600 or 800 When installation pitch of display unit is 500 When installation pitch of display unit is 400 ...

Страница 18: ...h the display unit placed on a clean blanket or the like with no dirt or foreign matter on it to prevent damage to the display unit z zThe display unit should be attached and removed by two persons if 25 kg 55 12 lbs or heavier and by four persons if 50 kg 110 23 lbs or heavier The display unit may drop and may cause injury so follow the instructions in the instruction manual of the display unit T...

Страница 19: ...e with the positioning hole in the base plate upper to the wall with a bolt C Use a level gauge to correct any tilting of the bracket D Fix the four remaining places with mounting holes in the base plate upper to the wall with bolts E Fix the five places with mounting holes in the base plate lower to the wall with bolts F Use a screwdriver to install the lock screw M5x200 in the base pate lower Ti...

Страница 20: ...h of the display unit and put a center mark on the top of the display unit B Put a mark to align the center of the display unit on the wall surface along a line extending from the positioning hole z zPut the mark on the wall surface at a position where it can also be checked when the display unit is lifted up z zThe positioning hole of the bracket attached to the wall becomes the center of the dis...

Страница 21: ...e display unit z zUse eye bolts with a diameter of ø41 mm 1 62 or less If the diameter of the eye bolts exceeds ø41 mm 1 62 you will not be unable to attach the eye bolts because the eye bolts and display unit will interfere with each other z zThere are operation parts on the rear of the display unit Take care not to bump them against anything nearby during installation z zIf disconnecting and con...

Страница 22: ...ert the hooks into the cutouts Attention z zIn addition to the workers who perform the work to attach the display unit people who serve as guides are required to direct the workers during the installation A top guide and side guide are required to check that the hooks are hooked into the cutouts a front guide is required to check the centering and an overall guide is required to check the overall ...

Страница 23: ... to the directions of each guide Side guide Hook Hooks Hooks Cutouts Cutouts D Immediately after installation pull the top of the display unit toward you to confirm that the gap between the display unit and wall does not increase and that the upper hook parts are definitely fixed in place E Pull the bottom of the display unit toward you to confirm that the gap between the display unit and wall doe...

Страница 24: ...Lower Lock screw Unlocked state when attaching display unit Locked state after attaching display unit Stopper Setting front view right Setting front view left 3 When removing the display unit A Use a long screwdriver to completely remove the lock screw that is locking the display unit The lock screw is removed by turning it counterclockwise z zThe display unit is still in the locked state if the l...

Страница 25: ...12 460 18 11 256 10 08 344 13 54 1120 8 44 2 811 3 32 0 Portrait 357 14 06 145 5 71 107 4 21 310 12 20 306 12 05 394 15 51 820 8 32 4 911 3 35 9 600 400 Landscape 407 16 02 195 7 68 157 6 18 360 14 17 206 8 11 294 11 57 920 8 36 3 732 6 28 9 Portrait 307 12 09 95 3 74 57 2 24 260 10 24 306 12 05 394 15 51 720 8 28 4 911 3 35 9 400 400 Landscape portrait 307 12 09 95 3 74 57 2 24 260 10 24 206 8 11...

Страница 26: ...e Screw name Screw nominal outer diameter Tightening torque N m Countersunk screw M4x6 M4 1 4 to 1 6 Set mount screw M6x12 M6 1 8 to 2 2 Set mount screw M8x20 M8 2 0 to 3 0 Lock screw M5x70 M5 1 4 to 1 6 Lock screw M5x200 M5 1 4 to 1 6 ...

Страница 27: ...ENGLISH 27 MEMO ...

Страница 28: ...TP0918MY0 PS Printed in China 2018 https panasonic net cns prodisplays ...

Отзывы: