LINEARITY ADJUSTMENT
S/W PULSE TEST PIN
PATH ADJ. JIG
TEST POINTS
ENVELOPE TEST PIN
PATH ADJ. JIG
MEASURING EQUIPMENT
OSCILLOSCOPE
VR CONTROL
PATH ADJ. JIG
ADJUSTMENT
S/T GUIDE ROLLER
TAPE TRANSPORTING SYSTEM
1)
Connect the PATH ADJ. JIG to PTO1 of the MAIN CIRCUIT BOARD.
2)
Play back the ALIGNMENT TAPE (COLOUR BAR SIGNAL).
3)
Connect the channel-1 scope probe to the S/W PULSE TEST PIN of the PATH ADJ. JIG.
4)
Connect the channel-2 scope probe to the ENVELOPE TEST PIN of the PATH ADJ. JIG.
5)
Adjust the VR CONTROL of the PATH ADJ. JIG for maximum envelope signal output of the alignment tape.
6)
Adjust the S/T GUIDE ROLLER until the envelope signal waveforms of the entrance and exit sides are as shown fig.48.
30
Linearity adjustment
Fig.48.
a: Max output of envelope
b: Min output of envelope
Содержание TX-21GV1
Страница 34: ...cp421vbl sch 1 Wed May 19 17 22 44 1999 VIDEO BLOCK DIAGRAM ...
Страница 35: ...cp421abl sch 1 Wed May 19 17 19 52 1999 AUDIO BLOCK DIAGRAM ...
Страница 36: ...cp421pbl1 sch 1 Wed May 19 17 21 31 1999 POWER BLOCK DIAGRAM ...
Страница 48: ...39 6 3 EXPLODED VIEW OF F L ASS Y 3 576 2 7 21 9 5 ...
Страница 50: ......
Страница 51: ...SCHEMATIC DIAGRAMS FOR MODELS ZEICHENERKLÄRUNG FÜR MODELL TX 21GV1C TX 14GV1C ...
Страница 52: ......
Страница 53: ......