96
English
Adjustment procedure
1
Connect between the 2 displays
using an RS-232C cross cable.
2
Select [2 screens colour matching
adjust] on the display to be adjusted,
and press <ENTER>.
A square is displayed in the center of the screen.
Sensor module
RS-232C cross cable
Reference display
Adjustment display
3
Set the front side of the sensor
toward the panel within the square
displayed on the reference display.
Sensor module
Reference display
Adjustment display
4
Select [Reference set measurement
start] and press <ENTER>.
5
When [Adjust OK] is displayed after
measurement, set the sensor on the
display to be adjusted.
Adjust OK
Reference set measurement start
Adjust set adjust start
Sensor module
Reference display
Adjustment display
6
Select [Adjust set adjust start] and
press <ENTER>.
7
When [Adjust OK] is displayed, the
adjustment is complete.
When [Adjust failed] is displayed, perform
adjustment again.
Adjust OK
Reference set measurement start
Adjust set adjust start
Adjust OK