jumpered AC plug and each exposed metallic cabinet part on the
equipment such as screwheads, connectors, control shafts, etc.
When the exposed metallic part has a return path to thechassis,
the reading should be between 1M and 5.2M . / When the
exposed metal does not have a return path to the chassis, the
reading must be
.
Figure 1
2.1.2. Leakage Current Hot Check (See
Figure 1
.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k , 10 watts resistor, in parallel with a 0.15 F
capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in
Figure 1
.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at
each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above
measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A
leakage current tester (Simpson Model 229 or equivalent) may be
used to make the hot checks, leakage current must not exceed 1/2
milliamp. In case a measurement is outsideof the limits specified,
there is a possibility of a shock hazard, and the equipment should
be repaired and rechecked before it is returned to the customer.
3. Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such
4
Содержание TH-42PHD6A
Страница 11: ...7 Location of Lead Wiring 9 ...
Страница 12: ...10 ...
Страница 28: ...16 Mechanical Replacement Parts List 26 ...
Страница 32: ...17 2 Electrical Replacement List 30 ...
Страница 34: ...C965 ECJ2VF1H103Z C 0 01UF Z 50V 1 32 ...
Страница 57: ...R2408 ERJ6GEYJ103 M 10KOHM J 1 10W 1 55 ...
Страница 79: ...C449 50 F1A3A102A040 C 1000PF J 1KV 2 77 ...
Страница 94: ...How to access the Option menu ...
Страница 98: ...1 Applicable signals 4 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...
Страница 103: ...6 Service Hint 9 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...
Страница 104: ...7 Location of Lead Wiring 10 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...
Страница 110: ...9 2 IIC mode structure following items value is sample data 16 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...