12.2. Contents of Option Menu
This chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful for
special function required customers. This should be set at the installation stage. The end user could not set or change these
because of hidden On screen menu.
Option menus
default setting
Contents
Off-timer function
Enable
Off-timer operation Enable/Disable.
On Screen display
On
Enable/Disable to display input mode indication after power on and no signal
indication.
Initial Input
Off
Sets the initial input mode when the power is turned on . Allow input mode
selection while power is on.
Initial VOL. level
Off
Sets the initial volume level when the power is turned on. Allow Volume control
while power is on.
Maximum VOL. Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input
mode by input selection key.
Button lock
Off
Enable/Disable front operation buttons (Input and/or volume up/down)
Studio W/B
Off
Set warm mode color temperature to 3,200 Kelvin.
Remocon User Level
Off
Remote key invalidation.
Off : Valid key is all key of remote.
User1 : Valid key are only Stand-by (ON/OFF), Input, Status, Surround, Sound
mute On/Off, and volume adjustment.
User2 : Valid key is only Stand-by (ON/OFF).
User3 : All keys are null and void
ID Select
0 to 100
Set ID number from 001 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial
Off
Serial ID function On/Off
Slot power
Off
Sets the slot power mode the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
Note :
How to set Remocon User Level and Remote ID off
1. Access service mode (CAT-mode) and press SET UP key on remote.
2. Accsess option menu.
3. Change Remocon User Level and/ or Remote ID set to Off.
30
TH-42PHW6EX / TH-42PHD6EX / TH-42PHD6BX / TH-42PHD6UY
Содержание TH-42PHD6A
Страница 11: ...7 Location of Lead Wiring 9 ...
Страница 12: ...10 ...
Страница 28: ...16 Mechanical Replacement Parts List 26 ...
Страница 32: ...17 2 Electrical Replacement List 30 ...
Страница 34: ...C965 ECJ2VF1H103Z C 0 01UF Z 50V 1 32 ...
Страница 57: ...R2408 ERJ6GEYJ103 M 10KOHM J 1 10W 1 55 ...
Страница 79: ...C449 50 F1A3A102A040 C 1000PF J 1KV 2 77 ...
Страница 94: ...How to access the Option menu ...
Страница 98: ...1 Applicable signals 4 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...
Страница 103: ...6 Service Hint 9 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...
Страница 104: ...7 Location of Lead Wiring 10 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...
Страница 110: ...9 2 IIC mode structure following items value is sample data 16 TH 42PHW6EX TH 42PHD6EX TH 42PHD6BX TH 42PHD6UY ...