2. Parts which have a mark in the circuit diagram or in the parts list are essential
for safety. When replacing these parts, be sure to use only the specified parts.
3. Use the specified types for internal wiring (double-insulated wiring, etc.).
4. When replacing parts on the AC primary side (power transformer, electric switch,
electrical cord, noise-prevention condenser, etc.), wind the lead wire and secure it
by soldering.
5. Do not let the wiring come into contact with heat-emitting devices (fuse resistor,
radiator plate, etc.).
6. When replacing the wiring, make sure that it is not in contact with the unfinished or
rough edge of a part.
7. When replacing the power cord (except for the plug-in type), tug it from various
directions to confirm that it does not slip out of place.
8. Spacing
If soldering was done on the AC primary circuit, confirm that the interval between
the soldered terminals or between the terminal and surrounding metallic parts is at
least the minimum required (between the primary circuit and the chassis: atleast
6.5 mm; between primary circuit terminals: at least 4.0 mm; between primary
circuit terminals and secondary circuit terminals: at least 6.5 mm.).
2. SAFETY PRECAUTION
2.1. Safety precaution
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only the manufacturer’s recommended components for
safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation
papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the
following insulation resistance test to prevent the customer from being exposed to
a shock hazard.
2.2. Insulation resistance test
1. Unplug the power cord and short the prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with an ohmmeter between the jumpered AC plug and
each exposed metal cabinet part, such as screw heads, connectors, control shafts,
7
Содержание SX-PR804P
Страница 9: ...6 PARTS LOCATION Figure 3 9 ...
Страница 10: ...7 DISASSEMBLY INSTRUCTIONS 10 ...
Страница 37: ...Check Point 1 Set to the Initial mode refer to OWNERS MANUAL 37 ...
Страница 38: ...11 2 Measuring condition of AS P C B 38 ...
Страница 40: ...12 SCHEMATIC DIAGRAM 13 PRINTED CIRCUIT BOARD 40 ...
Страница 49: ...C116 ECJ1VG1H221J 220P 1 MAIN 49 ...
Страница 51: ...C214 15 ECJ1VG1H471J 470P 2 MAIN 51 ...
Страница 53: ...CN3 SJPG7JS020A CONNECTOR 1 JACK 53 ...
Страница 57: ...D34 MA165TA5 DIODE 1 MA2C16500E CPR 57 ...
Страница 59: ...D57 MA165 DIODE 1 MA2C165 MKB1 59 ...
Страница 61: ...D85 LN282RPXVTX3 LED RED 1 LNJ282RKRX02 CPL 61 ...
Страница 63: ...D106 MA165 DIODE 1 MA2C165 MKB2 63 ...
Страница 65: ...D173 74 MA165TA5 DIODE 2 MA2C16500E CPCR 65 ...
Страница 67: ...IC16 17 C3ABMG000166 16M BIT PYNAMIC RAM 2 MAIN 67 ...
Страница 69: ...69 ...
Страница 74: ...R14 ERDS2FJ222 2200 1 PKB 74 ...
Страница 81: ...R289 90 ERJ3GEYJ473V 47K 2 D0GB473JA002 MAIN 81 ...
Страница 84: ...SW56 EVQ21507K PUSH SWITCH 1 CPR 84 ...
Страница 86: ...SW177 EVQ21507K PUSH SWITCH 1 CPCR 86 ...