8. SERVICE DIAGNOSTIC FUNCTION
The service diagnostic function makes it possible to determine whether the various
test modes pass or fail. The test modes are completely independent of one another.
Select a test mode as necessary, and run the test.
To set to the service diagnostic mode:
1. Press and hold the C#3, D#3, C#4 keys, and then turn on the power switch.
Figure-15
2. After the service diagnostic screen is displayed on the LCD, release the three keys.
3. Use the PAGE SELECT button below the display to select the respective test.
Figure-16