background image

1.3 Accessories

           9

Please be sure to confirm the content.
Please contact our distributor if any of the contents are insufficient.

1.4 Basic operation

This Product does not have a power ON/OFF switch. Connect the supplied power 
cord to this Switching Hub and connect the other end into an electric outlet. 
This Switching Hub operates at AC 100 - 240 V (50/60 Hz). 

When power is supplied, all the LEDs are turned ON. 
Then, PWR LED (Power) lights in green, STATUS/ECO LED (Status/ECO mode) lights 

in orange, and self-diagnosis of hardware is executed. 
On completion of self-diagnosis, PWR LED (Power) and STATUS/ECO LED 

(Status/ECO mode) light in green, and the Switching Hub starts operation as a 
Switching Hub. 
When this Switching Hub successfully communicates with a terminal connected to a 
port, the Port LED lights up. 
When the terminal is not operating normally, for example when power is not 
supplied to the terminal, the Port LED does not light up. 
When the Eco mode is set,Port LED lamps do not light up. 

For configuration and management method, please see the PDF version 
Operating Instructions in CD-ROM.

[Optional accessories]

[Power Cord]

The following power cords are supplied as per the intended nation of delivery.

Locale

Thailand

250 VAC 6 A

TIS166-2549

-

Indonesia

250 VAC 10 A

250 VAC 10 A

250 VAC 5 A

CEE7/7

BS1363

BS1363

-

13 A

5 A

Malaysia

Singapore

Product Number

PN28240i-TH

PN28240i-ID

PN28240i-MY

PN28240i-SG

Power Cord Rating FUSE Rated Current

Plug Type

 Installation Guide (this document) 

1

 CD-ROM (PDF version of Operating Instructions, ZEQUO assist Plus) 

1

 Rubber foot 

4

 Wall mount bracket 2

 Screw (for fixing the wall mount brackets to the Switching Hub) 

8

 Power cord 1

* Just the PN28240i-TH has 1 Installation Guide in Thailand (a total of 2 guides).

Quantity

(*)

PN54022-XX 1000BASE-SX SFP Module (i)

PN54024-XX 1000BASE-LX SFP Module (i)

The XXs are identical to the intended nation of delivery codes.

Содержание Switch-M24eGi

Страница 1: ...the Important Safety Instructions on pages from 3 to 5 Any problems or damage resulting from disassembly of this Switching Hub by customers are not covered by the warranty I0818 11019 Printed in Japan Switch M24eGi Installation Guide Model No PN28240i TH PN28240i MY PN28240i ID PN28240i SG 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 105 0021 2019 ...

Страница 2: ...eatures 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting on a wall 3 3 Mounting to rack 3 4 Configuration of IP address Basic Troubleshooting 3 6 7 7 8 9 9 10 13 15 15 16 17 18 20 ...

Страница 3: ...y this Switching Hub Deviation could lead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire and or electric shock Do not handle the power cord with wet hand Deviation could lead to electric shock and or equipment failure Do not ...

Страница 4: ...so that fingers or hands may not be damaged by twisted pair port SFP extension slot console port or power cord hook block Do not put the Switching Hub into fire Deviation could lead to explosion and or fire If the device is going to be used in high temperature environments do not perform the following operations with bare hands Relocating the installation area transporting and attaching and removi...

Страница 5: ...nications failures is extremely high in regard to systems that directly affect systems and human lives which require extremely high reliability Be aware of glitches which are caused in the usage environments such as age related degradation etc This may vary depending upon conditions such as utilisation rates and usage environments but performance might decrease due to the age related degradation e...

Страница 6: ... carpet Do not place it in the proximity Static electricity could lead to equipment failure Do not put a strong shock including dropping to this Switching Hub Deviation could lead to equipment failure Before connecting a console cable to the console port discharge static electricity for example by touching metal appliance do not discharge by touching this Switching Hub Do not store and or use this...

Страница 7: ...t and referring the history of loop on the setting screen Has a loop detection history function which notifies when a loop occurs with the corresponding LED and enables a network administrator to identify the looped port after the loop is removed Fanless design solves noise problem or fan failure Power consumption can be suppressed by switching off the port LEDs left via the ECO mode LED functions...

Страница 8: ... 1X authentication MAC based port based MAC authentication WEB authentication Triple authentication Storm control function multi cast address group registration function DDM function IPv6 supported IEEE802 1p compatible Supports 4 priority queues Temperature 0 60 C Humidity 20 80 RH no condensation Warning Failure to satisfy the conditions above may result in a fire electric shock equipment failur...

Страница 9: ...ly for example when power is not supplied to the terminal the Port LED does not light up When the Eco mode is set Port LED lamps do not light up For configuration and management method please see the PDF version Operating Instructions in CD ROM Optional accessories Power Cord The following power cords are supplied as per the intended nation of delivery Locale Thailand 250 VAC 6 A TIS166 2549 Indon...

Страница 10: ... port SFP extension slot ports 23 24 Install SFP extension module here It becomes exclusive usage with twisted pair port When SFP extension slot is linked the port is automatically switched to SFP extension mode SFP port supports only the full duplex communication Console port Transmission mode RS 232C Transmission speed 9 600 bps Stop bit 1 bit Flow control None Emulation mode VT100 Data length 8...

Страница 11: ...ht Starting Orange Blink Malfunction Contact the shop Off Power is OFF GIGA GIGA mode LED Green Light Operating in GIGA mode 100M Speed mode LED Green Light Operating in Speed mode FULL DUPLEX mode LED Green Light Operating in DUPLEX mode LOOP HISTORY Loop History mode LED Green Light Operating in Loop History mode Green Blink Loop is occurring or occurred within the last 3 days Power LED Collisio...

Страница 12: ...s or 10 Mbps or no device is connected 100M Green Light Link is established at 100 Mbps Off Link is established at 1000 Mbps or 10 Mbps or no device is connected FULL Green Light Link is established at full duplex Off Link is established at half duplex or no device is connected Orange Light Shutting down by loop detection Off Not shutting down by loop detection LOOP HISTORY Green Light Loop has be...

Страница 13: ...ode at the start is called Base mode There are two types of Base modes Status mode factory default setting and ECO mode You can change the Base mode by holding down the LED display switch button for at least 3 sec When the Base mode is changed normally all STATUS ECO GIGA 100M and FULL LED lamps light up at the same time When you release the button the Base mode is changed to the selected mode If ...

Страница 14: ...ponding port The Loop shutoff mode has the following 2 types of modes Block mode factory default When loops are detected the port statuses are automatically blocked and just the specified packets which include the loop detection packets will be transmitted and received Shut down mode When loops are being detected the ports will be automatically linked down and none of the packets will be transmitt...

Страница 15: ...ounding cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed while normal operating servicing or maintenance 5 Installation steps Step 1 Ensure the detachable ...

Страница 16: ...he four holes on each side of the Switching Hub Then securely install the Switching Hub onto the wall using the four screws which have been prepared by the customer It is recommended that the screws which are to be used with the screw retainers on the wall have head sizes with diameters of 9 4 mm or greater Right side Left side Installation and Configuration 3 16 Screw holes for wall mount bracket...

Страница 17: ... brackets to the four holes on each side of the Switching Hub using the screws Then securely install the Switching Hub on the rack using the four provided screws for mounting on a 19 inch rack or screws provided with the rack 3 3 Mounting to rack Right side Left side Screw holes for fixing the 19 inch rack mount brackets 17 ...

Страница 18: ...t System I P Configuration The screen to enter some addresses is displayed Screen 4 5 Press I to set an IP Address press M to set a Subnet Mask or press G to set a Default Gateway Then enter the specified address Screen 4 6 After completing the settings select Q uit to previous menu twice to return to Main Menu Screen 2 Here select Save Configuration to F lash Screen 5 and the command prompt chang...

Страница 19: ...een 3 Screen 5 Screen 4 For the following please see the PDF version Operating Instructions in CD ROM Detailed configuration and management methods using CLI WEB Configuration and management method from ZEQUO assist Plus 19 ...

Страница 20: ...ons are slow Are the communication speed and mode settings correct If the proper communication mode signal cannot be obtained apply half duplex mode Please reconfirm autonegotiation setting Do not set forced full duplex for the equipment that the Switching Hub is connected to Is not the utilization ratio of the network to which this Switching Hub is connected too high Please try to separate the eq...

Отзывы: