12
VII Parts
SUR-1261HP(AUS)
SUR-1271HP(AUS)
SUF-1271HP(AUS)
SUR-1561HP(AUS)
SUR-1571HP(AUS)
SUF-1571HP(AUS)
SUR-1871HPZ(AUH)
1
1
5
5
9
Support
1 small net racks
1 big net racks
Net rack
Ⅷ
. Safety Cautions / Warnings
rH
rL
CH
①
Whether the door is
closed?
②
Whether hot food is
put in?
The temperature in the cabinet is
12
℃
higher than the set temper-
ature,and the operation under this
temperature has kept on for more
than two hours. The indicated
temperature is the temperature in
the cabinet.
If reason above are excluded and the operation of the cabinet is not
normal or the temperature is indicated as H1,H2,L1,L2,
it is considered that the heat detector or other parts are abnormal.
When this kind of problem occur, please contact with the retailer or
consult in the customer’s service window.
Indication
Instructions
Examination Key Point
The temperature in the cabinet is
1
℃
lower than the set temperat-
ure,and the operation under thi
s
temperature has kept on for more
than two hour. The indicated
temperature is the temperature in
the cabinet.
2. On Defrosting
The cabinet makes use of heater strip to defrost. Microcomputer will
control the defrosting time. When the defrosting is carried out,the
temperature in the cabinet is indicated as [dEF]. The refrigeration
will restart again automatically five minutes after the defrosting is
finished. (With ten minutes after the defrosting has finished, in order
preventing the temperature in the cabinet from increasing, the cooling
fan will not run.)
7
Whether frozen foods
are put in the cabinet
which are melting?
The temperature of the export for
the condenser is more than 63
℃
and the condenser has operated
under this temperature for more
than 90 minutes. The indicated
temperature is the temperature in
the cabinet.
①
Whether the filter
net is blocked?
②
Whether the surro-
unding temperature
is too high?
CP
The temperature of the export for
the condenser is more than 70
℃