17
IX.
MainTechnical Parameters
Table 1 (Applicable to freezer with the volume
<
500L)
Table 2 (Applicable to freezer with the volume≥500L)
Note
:
1. If parameters in the table change, please refer to the nameplate.
2. Loading of net rack shall not exceed the values listed in the technical parameter table, otherwise, it may render
net rack to fall, causing damage.
3. Description for the meaning of climate type
Climate type code
Meaning description
Climate type code
1
2
3
4
5
Temperature and humidity condition
16
22
25
30
40
Dry-bulb
temperature ℃
Relative
humidity %
80
65
60
55
40
SN,N,ST,T
SN
N
ST
T
Subtemperate zone:10℃
~
32℃
Temperate zone:16℃
~
32℃
Subtropical zone:18℃
~
38℃
Tropical zone:18℃
~
43℃
SUR-1271HP(AUH)-NN SUR-1571HP(AUH)-NN
-
4
~
10
℃
240V~
6W
240V~ 8.4W
240V~ 50Hz
3
.
0m
NSG45NA
99kg
110kg
94kg
125kg
220-240V
50Hz
L: 40kg R:25kg
25kg
105kg
4
1200×750(+40)×850
91L
794×587×573
1200×750×850
1200×1300×850
794×437×573
138L
SUR-1871HP(AUH)-NNN
SUR-1271HP(AUH)-DW
155L
1094×587×573
1500×750×850
1094×437×573
185L
1500×1300×850
SUR-1571HP(AUH)-DW SUR-1871HP(AUH)-DWW
1800×750(+40)×850
264L
1394×587×573
1800×750×850
1800×1300×850
1394×437×573
267L
140kg
L:0.21
㎡
L: 0.30
㎡
L: 0.18
㎡
1.4A
260W
254W
37W
37W
62W
Commercial refrigerator
External air temperature is 30
℃
Without load balancing and direct sunlight shining
Net rack painted with polyethylene
Type I
Polyurethane
Cyclopentane
With ground terminal two-pole plug (Type I protection)
With ground terminal two-pole plug 10A 250V
(
W×D×H
)
(mm)
(
W×D×H
)
(mm)
Description
Model Number
Overall
Dimensions
Inner
Dimensions
Dimensions
Overall installation dimension
Overall operation dimension
Overall effective volume
Net rack
Max. workload of net rack(drawer)
Available area of refrigeration net rack
Rated frequency
Rated voltage
Rated current
Total power input
Total power input of defrosting
Rated power input of other thermoelectric element
Pe
rfo
rm
an
ce
Condition
InternalTemperature
Temperature Setting Range
Climate type
Compressor model
Fr
ee
zin
g
As
se
m
bly
Refrigerator
Blower
For Chiller
For Condenser
Power
Cord
Length
Plug
Applicable Socket
Power
Power
Weight
Anti-electric shock
protection category
Foaming agent
Material of foam layer
Below 0
℃
See the nameplane
Max. quanity of net rack
1
1. Please try to avoid acid, alkali and other environments containing
corrosive components. Such environment will corrode mechanical
parts of products, resulting in failure.
2. Please leave more than 30cm above the cabinet body space for
ventilation. Please put it in a place with the ambient temperature
at 5-35°C.
3. Please place it in a vertical or slightly inclined backwards place for
installation.
4.The product shall be installed on a ground is anti-water dropping
and immersion and is easy for drainage.
5. Please try to avoid direct sunlight or heating appliances, otherwise
it would reduce the cooling capacity.
6. Do not use it in outdoor. If use it under rain, leakage of electricity
electric shock and other accidents may occur. In addition, please
avoid water pipe, water tank and other places that are humid or
vulnerable to splash water.
II Selection of Installation Site
2
Cautions
1. Danger
①
Please do not put dangerous articles which are volatile, flammable
or explosive into the cabinet, otherwise explosion and fire may occur.
②
When abnormal matters occur, please cut off the power and stop
the running, otherwise electric shock and fire may happen.
III. Matters Need Attention
The appliance is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction.
③
Children being supervised not to play with the appliance.
④
1500×750(+40)×850
1200×750(+40)×850 1500×750(+40)×850 1800×750(+40)×850
1200×750×850 1500×750×850
1800×750×850
1200×1300×850 1500×1300×850 1800×1300×850
L: 40kg R:25kg L: 50kg R:25kg
43W
43W
58W