-32-
CNT-CLS 1, 2 (Output)
Two contact closure signals (Open collector type) are
output through the Alarm Output connector.
1. Move the cursor to CNT-CLS 1, and select OFF,
ALARM or AUX 1 with the joystick.
The factory default setting is OFF.
When ALARM is selected, TIME OUT appears.
Select an appropriate duration from among 100 MS,
200 MS, 1000 MS (1 s), 2000 MS (2 s) and 4000 MS
(4 s) with the joystick.
The factory default setting is 100 MS.
Note:
The shorter the duration, the more frequent
will be the detection output.
2. Move the cursor to CNT-CLS 2, then select OFF,
B/W or AUX 2 with the joystick.
The factory default setting is OFF.
OFF:
Contact closure signals are deactivated.
ALARM:
Available for CNT-CLS 1 only. A motion
detection signal is output.
AUX 1(2):
An alarm signal is output when the
camera receives a command from the controller.
B/W:
Available for CNT-CLS 2 only. ON (active) is
output when the camera operates in the black
and white mode if ALARM IN 4 is set to B/W.
Note:
It is recommended to set the connected
external device to ignore the shorter alarm
outputs of 90 ms or less from the camera.
COAXIAL ALARM OUT
Alarm output signals are supplied through the coaxial
cable.
1. Move the cursor to COAX ALM OUT and select ON
or OFF.
2. Press the CAM (SET) key.
The factory default setting is OFF.
ON:
The camera sends an alarm output signal after
it turns to a preset position.
OFF:
The camera does not send an output signal.
Notes:
• The camera ignores alarm inputs during manual
operation.
• Select OFF when the camera downloads or
uploads the preset data.
●
Cleaning (CLEANING)
With CLEANING in the ON position, the camera’s built-
in electromechanical contacts are cleaned at regular
intervals (approx. every 7 days).
A dry contact adversely affects picture quality and
motors operation.
1. Move the cursor to CLEANING and select ON or
OFF with the joystick.
ON:
The contacts are cleaned for approx. 1 minute.
"CLEANING" disappears when the cleaning
process is completed.
OFF:
No contact cleaning.
Note:
Select OFF when the camera downloads or
uploads the preset data.
●
Electronic Zoom (EL-ZOOM)
The electronic zoom magnifies a scene 10-fold. With a
22-fold optical zoom lens, the camera is capable of
220-fold zoom.
1. Move the cursor to EL-ZOOM and select ON or OFF
with the joystick, and then press the CAM (SET) key.
** SPECIAL 1 **
PRIVACY ZONE OFF
PROPO.P/T ON
AREA TITLE ON(USER)
PATROL STOP
ALARM IN/OUT
CLEANING ON
EL-ZOOM ON
PRESET ALM OFF
IMAGE HOLD OFF
TILT ANGLE 0
°
RET
CLEANING
** SPECIAL 1 **
PRIVACY ZONE OFF
PROPO.P/T ON
AREA TITLE ON(USER)
PATROL STOP
ALARM IN/OUT
CLEANING ON
EL-ZOOM ON
PRESET ALM OFF
IMAGE HOLD OFF
TILT ANGLE 0
°
RET
Содержание Super Dynamic II WV-CS854B