Page 1-18
1-4
Check Every 140 Hours (Once a Week)
1-4-1
Cleaning the Pickup
Clean the pickup.
1.
Turn off the power.
2.
Open the front safety cover.
3.
Pull out the cleaning unit in front of
machine.
4.
Take out the nozzle.
∗
Remove two bolts on the nozzle.
Slide the nozzle and remove from the pickup.
(see the left figure)
5.
Clean the nozzle.
∗
Wash the part with dirt, with IPA or ethanol.
∗
After cleaning, dry the nozzle fully before
setting it.
6.
Set the nozzle after cleaning, replace
the cleaning unit to the inside of main
body.
REL
EA
SE
TR
IP
O
F
F
ON
RE
S
E
T
193C-E-MMA01-A04-00
Center safety cover
193C-AC00
193C-017P
193C-003E
Nozzle
Cleaning unit