© Panasonic Industrial Devices SUNX Co., Ltd. 2014
77
Function
<Timing chart>
ON
OFF
ON
OFF
ON
OFF
Muting sensor C
0.03 to under 3 sec.
ON
OFF
Control output
(OSSD 1 / 2)
Light
received
Light
blocked
Light received
status
Muting sensor A
Muting sensor B
ON
OFF
Muting sensor D
ON
OFF
0.05 sec. or less
14ms or less
Muting function
<Reference>
It is possible to set the muting function into invalid per beam channel respectively and to specify the
input order of the muting input A and B to be set into valid by using the handy controller (
SFB-HC
)
(optional).
<Auxiliary muting output wiring>
To trigger a large multi-purpose indicator during muting operation, connect the wiring as follows:
As for lead wires other than below, perform wiring depending on your application.
For details, refer to “
2-5 Wiring
.”
+
24V DC
±10%
-
Receiver
Emitter
(Brown) +V
(Brown) +V
(Blue) 0V
(Blue) 0V
(Orange) Synchroni
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Red) Muting auxiliary output
(Gray / Black) Large multi-purpose indicator input (Emitter side)
(Gray / Black) Large multi-purpose indicator input (Receiver side)
Gray cable
with black line
Gray cable
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com