© Panasonic Industrial Devices SUNX Co., Ltd. 2014
13
Part Description
●
Common to emitter and receiver
Description
Function
Large multi-purpose indicator (Orange)
(Mounted on SF4B-
□
CA-J05
only)
When input for the large multi-purpose indicator is validated: lights up
When input for the large multi-purpose indicator is invalidated: OFF
Beam-axis alignment indicator
(Red / Green)
A
When device top receives light: lights up in red
When device top end receives light: blinks in red
When control output (OSSD 1 / 2) is ON: lights up in green
B
When device upper middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
C
When device lower middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
D
When device bottom receives light: lights up in red
When device bottom end receives light: blinks in red
When control output (OSSD 1 / 2) is ON: lights up in green
Incident light intensity indicator
(Orange / Green) [STB]
When stable light is received: lights up in green
When unstable light is received: lights up in orange
When light is blocked (Note 1): OFF (Note 3)
Fault indicator (Yellow) [FAULT]
When fault occurs in the device: lights up or blinks
PNP indicator (Orange) [PNP]
When PNP output is set: lights up
NPN indicator (Orange) [NPN]
When NPN output is set: lights up
●
Emitter
Description
Function
Operator indicator (Red / Green)
[OSSD] (Note 2)
Both end beam channels are received: blinks in red
All beam channels are received: lights up in green
When control output (OSSD 1 / 2) is OFF: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
Emission intensity control indicator
(Orange) [CTRL]
When emission intensity is controlled: lights up
Emission halt indicator (Orange)
[HALT]
When light emission is halt: lights up
When light is emitted: OFF
●
Receiver
Description
Function
OSSD indicator (Red / Green) [OSSD]
Both end beam channels are received: blinks in red
All beam channels are received: lights up in green
When control output (OSSD 1 / 2) is OFF: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
Function setting indicator (Orange)
[FUNCTION]
When connecting the handy controller: brinks
When blanking function is used: lights up (Note 3)
Interlock indicator (Yellow)
[INTERLOCK]
When device is interlocked: lights up
Other cases: OFF
Notes: 1) “When light is blocked” refers to the status that there exists any object blocking light in the sensing area.
2) Since the color of the operation indicator changes according to ON / OFF status of the control output
(OSSD 1 / 2), the operation indicator is marked as “OSSD” on the device.
3) The blanking function is set by using the handy controller (
SFB-HC
) (optional). Please purchase the
handy controller separately.
4) The description given in [ ] is marked on the device.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com