background image

5

Names of Parts 

Operation Mechanism

 

„

Heating performance

 

z

Since this air conditioner utilizes outside air for heating, 

its heating performance deteriorates as outside tempera-

ture decreases.

(Due to heat pump system)

→In that case, use another heating appliance.

 

„

Defrosting

 

z

This appliance may start defrosting operation to melt 

frost formed in the outdoor unit.

1

 

Defrosting starts

: The indoor unit fan stops (or the 

speed becomes extremely slow).

→”  ” (STANDBY) appears.

2

 

Heating operation resumes after several 

minutes

: The indoor unit fan remains stopped (or 

it will run at a very slow speed) until the indoor heat 

exchanger coil warms up suffi ciently.

→ ” ” (STANDBY) is shown.

3

 

Defrosting is complete

: The indoor unit fan starts 

operation.

→ ”  ” (STANDBY) disappears.

INDOOR UNIT

T2 type

 (Ceiling)

 

„

‘‘DRY’’ operation

 

z

Once the room temperature reaches the level that was 

set, the outdoor unit repeats the cycle of turning on and 

off automatically.

 

z

When the outdoor unit is turned off, the indoor unit fan 

will stop, too.

(To prevent the humidity in the room from rising again)

 

z

When the room temperature is more likely to reach the 

level that was set, the fan speed is set to ‘‘breeze’’ (light 

wind) automatically.

 

z

‘‘DRY’’ operation is not possible if the outdoor tempera-

ture is 15 °C or less.

 

„

Should the power failure occurs while the 

unit is running

When the unit automatically resumes operation after 

temporary power failure, it uses the same settings before 

the power was cut off.

OUTDOOR UNIT

U1 type

 (4-Way Cassette)

Air intake

Air outlet

Air intake

Air outlet

60, 71 type

100, 125, 140 type

Model No.

CZ-RWSU2 (U1 type)

CZ-RWST3 (T2 type)

Optional

Wireless Remote Controller

Model No.

CZ-RTC2

For all indoor 

units

Timer Remote Controller

Model No.

CZ-RTC3

For all indoor 

units

Read the operating instructions included with the Remote Controller.

High-spec Wired Remote Controller

Water drain

Ceiling panel 

(optional)
Air outlet

(4 locations)
Air intake grille

(air intake)

Air outlet

Air intake grille

(air intake)

Water drain

F569618_L.indb   5

2013-12-4   14:57:21

Содержание S-60PT2R5A

Страница 1: ...T2R5A S 60PU1R5A S 71PU1R5A S 100PU1R5A S 125PU1R5A S 140PU1R5A Before operating the unit read these operating instructions thoroughly and keep them for future reference Panasonic Corporation 1006 Kad...

Страница 2: ...t to the sales dealer or service dealer for a repair WARNING z z Safety Precautions 2 z z Precautions for Use 4 z z Names of Parts 5 Operation Mechanism 5 z z Adjusting Airflow Direction 6 Adjusting a...

Страница 3: ...orated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspe...

Страница 4: ...lectrician Operation Preparation Turn the power mains on 5 hours before the start of operation For warm up z z Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a recept...

Страница 5: ...g on and off automatically z When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again z When the room temperature is more likely to r...

Страница 6: ...for cooling operation With the downward setting condensation may drip on to the floor U1 T2 type HEAT COOL DRY FAN Airflow direction display Airflow direction display FLAP button FLAP button Fan and...

Страница 7: ...m entering the room Do z z Always keep the air filter clean A clogged filter will impair the performance of the unit Maintenance P 8 z z To prevent conditioned air from escaping keep win dows doors an...

Страница 8: ...r The operation power button is turned off If the breaker is turned off turn the power on If the breaker has been tripped consult your dealer without turning it on Fuse blow out Contact your dealer Po...

Страница 9: ...at exchanger depending on the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is...

Страница 10: ...0 353 950 950 353 950 950 353 950 950 Net weight kg 28 28 31 31 31 Values include the dimension and weight of an optional ceiling panel Ceiling T2 type Model Name S 60PT2R5A S 71PT2R5A S 100PT2R5A S 1...

Страница 11: ...r level C H dB A 65 67 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 69 98 98 98 Model Name U 100PE1R8A U 125PE1R8...

Страница 12: ...F569618 DC1213 0 Panasonic Corporation Website http panasonic net Printed in China Panasonic Corporation 2014...

Отзывы: