9

Troubleshooting

Symptom

Cause / Action

Indoor unit

Noise

Sound like streaming water is heard 

during operation or after operation.

• Sound of refrigerant liquid 

fl

 owing inside unit

• Sound of drainage water through drain pipe

Cracking noise is heard during operation 

or when operation stops.

Sound due to temperature changes of parts

Discharged air smells during operation.

• Indoor odor components, cigarette odor and cosmetic odor 

accumulated in the air conditioner and its air is discharged.

• The unit inside is dirty.

(Contact your dealer.)

Dewdrops accumulate near the air outlet 

during cooling operation.

• Internal moisture is cooled by cool wind and accumulates as 

dewdrops.

Fog occurs during cooling operation.

• If the air conditioner has been installed at places such as 

restaurants where large amounts of oil mist exist, cleaning is 

necessary because the unit inside (heat exchanger) is dirty.

(Contact your dealer.)

Fog occurs during heating operation.

• Defrost operation is in process.

The fan is rotating for a while even though 

operation stops.

• Fan rotation makes operation smooth.

• The fan may rotate to dry the heat exchanger depending on 

the setting.

Air

fl

 ow 

direction

Air

fl

 ow direction changes while operating.

Air

fl

 ow direction cannot be set.

Air

fl

 ow direction cannot be changed.

• When air discharge temperature is low during heating 

operation, or during defrost operation, horizontal wind 

fl

 ow is 

made automatically.

• The 

fl

 ap position may be set individually.

(U1 type)

The 

fl

 ap moves several times after the 

direction is changed.

• The 

fl

 ap moves to the standard position once, and then turns 

to the set air

fl

 ow direction.

Dust is discharged.

• Dust accumulated inside the indoor unit is discharged.

At the initial high-speed operation, the fan 

sometimes rotates faster than the setting 

speed.

(3 to 30 minutes)

• This is for operation check in order to con

fi

 rm whether the fan 

motor rotation is within the range of use.

Outdoor unit

No operation

(When the power is turned on immediately / 

When operation is stopped and resumed 

immediately)

• Operation is not activated for the 

fi

 rst approx. 3 minutes 

because the compressor protection circuit is activated.

Noise occurs during heating operation.

• Defrost operation is in process.

Steam comes out during heating operation.

The fan continues to rotate even after the 

operation is stopped using the remote 

controller.

• This is for smooth operation.

Check before consulting or requesting services.

F569022.indb   9

F569022.indb   9

2013/06/07   8:59:47

2013/06/07   8:59:47

Содержание S-60PT2R5

Страница 1: ...S 140PT2R5 S 60PU1R5 S 71PU1R5 S 100PU1R5 S 125PU1R5 S 140PU1R5 Before operating the unit read these operating instructions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan OUTDOOR UNIT Single Split Single phase U 60PE1R5 U 71PE1R5 U 100PE1R5 U 125PE1R5 U 140PE1R5 Single Split 3 phase U 100PE1R8 U 125PE1R8 U 140PE1R8 F569022 ...

Страница 2: ... turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency Do not clean inside the indoor and outdoor units by users Engage authorized dealer or specialist for cleaning In case ...

Страница 3: ...om insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips frequently The product sometimes does ...

Страница 4: ...eration Preparation Turn the power mains on 5 hours before the start of operation For warm up Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under th...

Страница 5: ...locations Air intake grille air intake Optional For all indoor units For all indoor units DRY operation Once the room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again When the room temperature is more likely to ...

Страница 6: ...ating operation With the upward setting warm air cannot reach the floor Set the flap to the upward position for cooling operation With the downward setting condensation may drip on to the floor U1 T2 type HEAT COOL DRY FAN Airflow direction display Airflow direction display FLAP button FLAP button Fan and heating Cooling and drying 5 levels 3 levels Recommended Recommended Fixed to this position A...

Страница 7: ...ilter clean A clogged filter will impair the performance of the unit Maintenance P 8 To prevent conditioned air from escaping keep win dows doors and any other openings closed Adjusting airflow direction for multiple indoor units Timer remote controller only When setting the airflow direction of each indoor unit individually 1 Press to select the Unit No for adjustment 2 Press to select your desir...

Страница 8: ...eration power button is turned off If the breaker is turned off turn the power on If the breaker has been tripped consult your dealer without turning it on Fuse blow out Contact your dealer Poor cooling or heating performance The air intake or air outlet of indoor and outdoor units is clogged with dust Remove the dust The wind speed switch is set to Low Change to High or Strong Improper temperatur...

Страница 9: ...eat exchanger depending on the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operation or during defrost operation horizontal wind flow is made automatically The flap position may be set individually U1 type The flap moves several times after the direction ...

Страница 10: ...ions H W D mm 290 950 950 290 950 950 353 950 950 353 950 950 353 950 950 Net weight kg 28 28 31 31 31 Ceiling T2 type Model Name S 60PT2R5 S 71PT2R5 S 100PT2R5 S 125PT2R5 S 140PT2R5 Power source 230 240 V 50 Hz Cooling capacity kW 6 0 7 1 10 0 12 5 14 0 BTU h 20 500 24 200 34 100 42 700 47 800 Heating capacity kW 7 0 8 0 11 2 14 0 16 0 BTU h 23 900 27 300 38 200 47 800 54 600 Sound pressure level...

Страница 11: ...r level C H dB A 65 67 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 69 98 98 98 Model Name U 100PE1R8 U 125PE1R8 U 140PE1R8 Power source 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capacity kW 11 2 14 0 16 0 BTU h 38 200 47 800 54 600 Sound pressure level C H dB A 52 ...

Страница 12: ...F569022 DC0413 10613 Panasonic Corporation Website http panasonic net Printed in China Panasonic Corporation 2013 ...

Отзывы: