Panasonic S-60PT2R5 Скачать руководство пользователя страница 4

4

Precautions for Use

Installation

 

This air conditioner must be installed properly by quali

fi

 ed 

installation technicians in accordance with the Installation 

Instructions provided with the unit.

 

Before installation, check that the voltage of the electric sup-

ply in your home or of

fi

 ce is the same as the voltage shown 

on the nameplate.

WARNING

Avoid the following locations for installation.

 

Locations where smoke or combustible gas exists.

Also locations of extremely high temperature such as a 

greenhouse.

 

Locations where excessively high heat-generating ob-

jects are placed.

Attention:

 

Avoid installing the outdoor unit where salty sea water can 

splash directly onto it or in sulphurous air near a spa.

(To protect the air conditioner from heavy corrosion)

Wiring

 

All wiring must conform to the local electrical codes.

(Consult your dealer or a quali

fi

 ed electrician for details.)

 

Each unit must be properly grounded with a ground (or 

earth) wire or through the supply wiring.

 

Wiring must be done by a quali

fi

 ed electrician.

Operation Preparation

Turn the power mains on 5 hours before 

the start of operation.

(For warm-up)

 

Leave the power mains ON for continuous use.

ON

NOTE

Pull off the power plug from a receptacle, or switch off the 

breaker, or switch off the power disconnecting mean to isolate 

the air conditioner from the main power supply when not in use 

for a long time.

Operation Condition

Use this air conditioner under the following temperature range.

 Indoor temperature range:

Cooling mode  14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT)

Heating mode  16°C ~ 30°C (*DBT)

 Outdoor temperature range:

Cooling mode  -15°C ~ 46°C (*DBT)

Heating mode  -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT)

*DBT: Dry bulb temperature

*WBT: Wet bulb temperature

Information for Users on Collection and Disposal of 
Old Equipment and Used Batteries

[Information on Disposal in other Countries 

outside the European Union] 

These symbols are only valid in the European 

Union. If you wish to discard these items, 

please contact your local authorities or dealer 

and ask for the correct method of disposal.

Pb

Note for the battery symbol (bottom two 

symbol examples):

This symbol might be used in combination with 

a chemical symbol. In this case it complies 

with the requirement set by the Directive for 

the chemical involved.

F569022.indb   4

F569022.indb   4

2013/06/07   8:59:45

2013/06/07   8:59:45

Содержание S-60PT2R5

Страница 1: ...S 140PT2R5 S 60PU1R5 S 71PU1R5 S 100PU1R5 S 125PU1R5 S 140PU1R5 Before operating the unit read these operating instructions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan OUTDOOR UNIT Single Split Single phase U 60PE1R5 U 71PE1R5 U 100PE1R5 U 125PE1R5 U 140PE1R5 Single Split 3 phase U 100PE1R8 U 125PE1R8 U 140PE1R8 F569022 ...

Страница 2: ... turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency Do not clean inside the indoor and outdoor units by users Engage authorized dealer or specialist for cleaning In case ...

Страница 3: ...om insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips frequently The product sometimes does ...

Страница 4: ...eration Preparation Turn the power mains on 5 hours before the start of operation For warm up Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under th...

Страница 5: ...locations Air intake grille air intake Optional For all indoor units For all indoor units DRY operation Once the room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again When the room temperature is more likely to ...

Страница 6: ...ating operation With the upward setting warm air cannot reach the floor Set the flap to the upward position for cooling operation With the downward setting condensation may drip on to the floor U1 T2 type HEAT COOL DRY FAN Airflow direction display Airflow direction display FLAP button FLAP button Fan and heating Cooling and drying 5 levels 3 levels Recommended Recommended Fixed to this position A...

Страница 7: ...ilter clean A clogged filter will impair the performance of the unit Maintenance P 8 To prevent conditioned air from escaping keep win dows doors and any other openings closed Adjusting airflow direction for multiple indoor units Timer remote controller only When setting the airflow direction of each indoor unit individually 1 Press to select the Unit No for adjustment 2 Press to select your desir...

Страница 8: ...eration power button is turned off If the breaker is turned off turn the power on If the breaker has been tripped consult your dealer without turning it on Fuse blow out Contact your dealer Poor cooling or heating performance The air intake or air outlet of indoor and outdoor units is clogged with dust Remove the dust The wind speed switch is set to Low Change to High or Strong Improper temperatur...

Страница 9: ...eat exchanger depending on the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operation or during defrost operation horizontal wind flow is made automatically The flap position may be set individually U1 type The flap moves several times after the direction ...

Страница 10: ...ions H W D mm 290 950 950 290 950 950 353 950 950 353 950 950 353 950 950 Net weight kg 28 28 31 31 31 Ceiling T2 type Model Name S 60PT2R5 S 71PT2R5 S 100PT2R5 S 125PT2R5 S 140PT2R5 Power source 230 240 V 50 Hz Cooling capacity kW 6 0 7 1 10 0 12 5 14 0 BTU h 20 500 24 200 34 100 42 700 47 800 Heating capacity kW 7 0 8 0 11 2 14 0 16 0 BTU h 23 900 27 300 38 200 47 800 54 600 Sound pressure level...

Страница 11: ...r level C H dB A 65 67 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 69 98 98 98 Model Name U 100PE1R8 U 125PE1R8 U 140PE1R8 Power source 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capacity kW 11 2 14 0 16 0 BTU h 38 200 47 800 54 600 Sound pressure level C H dB A 52 ...

Страница 12: ...F569022 DC0413 10613 Panasonic Corporation Website http panasonic net Printed in China Panasonic Corporation 2013 ...

Отзывы: