Names of Parts 

Air outlet

Operation Mechanism

 Heating performance

 

Since this air conditioner utilizes outside air for heating, 

its heating performance deteriorates as outside tempera-

ture decreases.

(Due to heat pump system)

In that case, use another heating appliance.

 Defrosting

 

This appliance may start defrosting operation to melt 

frost formed in the outdoor unit.

1

Defrosting starts

: The indoor unit fan stops (or the 

speed becomes extremely slow).

”  ” (STANDBY) appears.

2

Heating operation resumes after several 

minutes

: The indoor unit fan remains stopped (or 

it will run at a very slow speed) until the indoor heat 

exchanger coil warms up suf

fi

 ciently.

 ” ” (STANDBY) is shown.

3

 

Defrosting is complete

: The indoor unit fan starts 

operation.

 ”  ” (STANDBY) disappears.

INDOOR UNIT

T2 type

 (Ceiling)

Water drain

Ceiling panel 

(optional)

Air outlet

(4 locations)

Air intake grille

(air intake)

Optional

For all indoor units

For all indoor 

units

 ‘‘DRY’’ operation

 

Once the room temperature reaches the level that was 

set, the outdoor unit repeats the cycle of turning on and 

off automatically.

 

When the outdoor unit is turned off, the indoor unit fan 

will stop, too.

(To prevent the humidity in the room from rising again)

 

When the room temperature is more likely to reach the 

level that was set, the fan speed is set to ‘‘breeze’’ (light 

wind) automatically.

 

‘‘DRY’’ operation is not possible if the outdoor tempera-

ture is 15 °C or less.

 Should the power failure occurs while the 

unit is running

When the unit automatically resumes operation after 

temporary power failure, it uses the same settings before 

the power was cut off.

Air intake grille

(air intake)

Wireless Remote Controller

Timer Remote Controller

Water drain

Read the operating instructions included 

with the Remote Controller.

OUTDOOR UNIT

U1 type

 (4-Way Cassette)

Air intake

Air outlet

Air intake

Air outlet

60, 71 type

100, 125, 140 type

F569022.indb   5

F569022.indb   5

2013/06/07   8:59:45

2013/06/07   8:59:45

Содержание S-60PT2R5

Страница 1: ...S 140PT2R5 S 60PU1R5 S 71PU1R5 S 100PU1R5 S 125PU1R5 S 140PU1R5 Before operating the unit read these operating instructions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan OUTDOOR UNIT Single Split Single phase U 60PE1R5 U 71PE1R5 U 100PE1R5 U 125PE1R5 U 140PE1R5 Single Split 3 phase U 100PE1R8 U 125PE1R8 U 140PE1R8 F569022 ...

Страница 2: ... turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency Do not clean inside the indoor and outdoor units by users Engage authorized dealer or specialist for cleaning In case ...

Страница 3: ...om insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips frequently The product sometimes does ...

Страница 4: ...eration Preparation Turn the power mains on 5 hours before the start of operation For warm up Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under th...

Страница 5: ...locations Air intake grille air intake Optional For all indoor units For all indoor units DRY operation Once the room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again When the room temperature is more likely to ...

Страница 6: ...ating operation With the upward setting warm air cannot reach the floor Set the flap to the upward position for cooling operation With the downward setting condensation may drip on to the floor U1 T2 type HEAT COOL DRY FAN Airflow direction display Airflow direction display FLAP button FLAP button Fan and heating Cooling and drying 5 levels 3 levels Recommended Recommended Fixed to this position A...

Страница 7: ...ilter clean A clogged filter will impair the performance of the unit Maintenance P 8 To prevent conditioned air from escaping keep win dows doors and any other openings closed Adjusting airflow direction for multiple indoor units Timer remote controller only When setting the airflow direction of each indoor unit individually 1 Press to select the Unit No for adjustment 2 Press to select your desir...

Страница 8: ...eration power button is turned off If the breaker is turned off turn the power on If the breaker has been tripped consult your dealer without turning it on Fuse blow out Contact your dealer Poor cooling or heating performance The air intake or air outlet of indoor and outdoor units is clogged with dust Remove the dust The wind speed switch is set to Low Change to High or Strong Improper temperatur...

Страница 9: ...eat exchanger depending on the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operation or during defrost operation horizontal wind flow is made automatically The flap position may be set individually U1 type The flap moves several times after the direction ...

Страница 10: ...ions H W D mm 290 950 950 290 950 950 353 950 950 353 950 950 353 950 950 Net weight kg 28 28 31 31 31 Ceiling T2 type Model Name S 60PT2R5 S 71PT2R5 S 100PT2R5 S 125PT2R5 S 140PT2R5 Power source 230 240 V 50 Hz Cooling capacity kW 6 0 7 1 10 0 12 5 14 0 BTU h 20 500 24 200 34 100 42 700 47 800 Heating capacity kW 7 0 8 0 11 2 14 0 16 0 BTU h 23 900 27 300 38 200 47 800 54 600 Sound pressure level...

Страница 11: ...r level C H dB A 65 67 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 69 98 98 98 Model Name U 100PE1R8 U 125PE1R8 U 140PE1R8 Power source 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capacity kW 11 2 14 0 16 0 BTU h 38 200 47 800 54 600 Sound pressure level C H dB A 52 ...

Страница 12: ...F569022 DC0413 10613 Panasonic Corporation Website http panasonic net Printed in China Panasonic Corporation 2013 ...

Отзывы: