60/62
Hexadecimal 02h *1
FEh
FEh 03h
Remarks STX
ID Command
Option
ETX
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *5 FEh FEh *2 *3 *4 — *15 *16 *17 03h
STX
ID
Parameters
Acceptability
SECURITY STNDBY NO
SIGNAL SHUTTER TEST
PATTERN REMOTE2
Yes Yes Yes Yes
Yes
Yes
Parameters (*2—*17)
Bit Name
Description
Condition
of
Clear
Bit
0
Temperature warning (IN)
Intake air temperature is the specific value or higher.
It is less than the specific
value.
1
Temperature warning (OPT)
Optical module (DMD surroundings) temperature is the
specific value or higher.
It is less than the specific
value.
2
Temperature warning (OUT)
Exhaust air temperature is the specific value or higher.
It is less than the specific
value.
3
Low temperature warning (OPT)
Optical module (DMD surroundings) temperature is less than
the specific value.
It is the specific value or
higher.
4
Temperature error (IN)
Intake air temperature is the specific value or higher.
It is less than the specific
value.
5
Temperature error (OPT)
Optical module (DMD surroundings) temperature is the
specific value or higher.
It is less than the specific
value.
6
Temperature error (OUT)
Exhaust air temperature is the specific value or higher.
It is less than the specific
value.
7
Low temperature error (OPT)
Optical module (DMD surroundings) temperature is less than
the specific value.
It is the specific value or
higher.
8
Lamp 1 operating time warning
9
Lamp 2 operating time warning
10
Lamp 3 operating time warning
11
Lamp 4 operating time warning
Lamp cumulative usage time is the specific value or longer.
12
Lamp 1 operating time exceeded
13
Lamp 2 operating time exceeded
14
Lamp 3 operating time exceeded
15
Lamp 4 operating time exceeded
Lamp cumulative usage time is the specific value or longer.
Lamp replacement
16
Lamp 1 going out
17
Lamp 2 going out
18
Lamp 3 going out
19
Lamp 4 going out
Lamp-Goes out after turning on.
20
Lamp 1 lighting failure
21
Lamp 2 lighting failure
22
Lamp 3 lighting failure
23
Lamp 4 lighting failure
Lamp ignition failure
Executes the lamp
turning on processing.
24
Lamp 1 not installed
25
Lamp 2 not installed
26
Lamp 3 not installed
27
Lamp 4 not installed
Lamp not installed, or Lamp memory read failure
MAIN POWER ON after
the lamp is installed, or
Lamp memory
initialization
28
AC power supply voltage drop
warning (less than 90 V)
29
Lamp unit cover is not closed
Lamp unit cover is not closed for 1 second or longer.
POW ER ON after the lamp
unit cover is closed
30 —
31 —
2.151. SELF CHECK Information