59/62 

 

  ID of the extended control command 

ID 

Hexadecimal 

(1 byte) 

 

ID 

Hexadecimal 

(1 byte) 

 

ID 

Hexadecimal 

(1 byte) 

 

ID Hexadecimal 

(1 byte) 

ALL 00 

 

ID23 17 

 

ID46 2E 

 

Group E 

84 

ID1 01 

 

ID24 18 

 

ID47 2F 

 

Group F 

85 

ID2 02 

 

ID25 19 

 

ID48 30 

 

Group G 

86 

ID3 03 

 

ID26 1A 

 

ID49 31 

 

Group H 

87 

ID4 04 

 

ID27 1B 

 

ID50 32 

 

Group I 

88 

ID5 05 

 

ID28 1C 

 

ID51 33 

 

Group J 

89 

ID6 06 

 

ID29 1D 

 

ID52 34 

 

Group K 

8A 

ID7 07 

 

ID30 1E 

 

ID53 35 

 

Group L 

8B 

ID8 08 

 

ID31 1F 

 

ID54 36 

 

Group M 

8C 

ID9 09 

 

ID32 20 

 

ID55 37 

 

Group N 

8D 

ID10 0A 

 

ID33 21 

 

ID56 38 

 

Group O 

8E 

ID11 0B 

 

ID34 22 

 

ID57 39 

 

Group P 

8F 

ID12 0C 

 

ID35 23 

 

ID58 3A 

 

Group Q 

90 

ID13 0D 

 

ID36 24 

 

ID59 3B 

 

Group R 

91 

ID14 0E 

 

ID37 25 

 

ID60 3C 

 

Group S 

92 

ID15 0F 

 

ID38 26 

 

ID61 3D 

 

Group T 

93 

ID16 10 

 

ID39 27 

 

ID62 3E 

 

Group U 

94 

ID17 11 

 

ID40 28 

 

ID63 3F 

 

Group V 

95 

ID18 12 

 

ID41 29 

 

ID64 40 

 

Group W 

96 

ID19 13 

 

ID42 2A 

 

Group A 

80 

 

Group X 

97 

ID20 14 

 

ID43 2B 

 

Group B 

81 

 

Group Y 

98 

ID21 15 

 

ID44 2C 

 

Group C 

82 

 

Group Z 

99 

ID22 16 

 

ID45 2D 

 

Group D 

83 

 

 

 

 

Hexadecimal 

02h *1 B1h 

7Ch *2 *3 *4 03h 

Remarks STX ID  Command 

Parameters 

ETX 

 

Parameters (*2) 

 

LENS SHIFT H 

LENS SHIFT V 

LENS FOCUS 

LENS ZOOM 

Hexadecimal 00h 

01h 

02h 

03h 

 

Parameters (*3) 

 Slowly 

Normal 

Fast 

Home 

position 

Hexadecimal 00h 

01h 

02h 

80h 

 

Parameters (*4) 

 

Right / Up / Forward / In / Cancel 

Left / Down / Backward / Out / Start 

Hexadecimal 00h 

01h 

 

Note: 

• It is effective only when the parameter (*2) is LENS SHIFT H (00h) or LENS SHIFT V (01h). 

 

Response (Callback) 

In the period when the command can be accepted 

Hexadecimal 

02h *5 B3h 

7Ch 

*2 *3 *4 03h 

 STX 

ID 

Callback  Parameters ETX 

In the period when the command cannot be accepted 

Hexadecimal 02h  *5  FFh 03h 

 STX 

ID 

Error 

ETX 

Acceptability 

SECURITY STNDBY NO 

SIGNAL SHUTTER TEST 

PATTERN REMOTE2 

Yes No  Yes  Yes 

Yes 

Yes 

2.150. Lens  Control 

Содержание RS-232C

Страница 1: ...Panasonic Projector RS 232C Control Specifications PT DW10000 D10000 ...

Страница 2: ... AD25 ID48 AD48 Group G AD0G ID3 AD03 ID26 AD26 ID49 AD49 Group H AD0H ID4 AD04 ID27 AD27 ID50 AD50 Group I AD0I ID5 AD05 ID28 AD28 ID51 AD51 Group J AD0J ID6 AD06 ID29 AD29 ID52 AD52 Group K AD0K ID7 AD07 ID30 AD30 ID53 AD53 Group L AD0L ID8 AD08 ID31 AD31 ID54 AD54 Group M AD0M ID9 AD09 ID32 AD32 ID55 AD55 Group N AD0N ID10 AD10 ID33 AD33 ID56 AD56 Group O AD0O ID11 AD11 ID34 AD34 ID57 AD57 Grou...

Страница 3: ...or received for 10 to 60 seconds after the lamp starts lighting Try sending any command after that period has elapsed When sending several commands be sure to wait for a response from the projector and send the next command after 0 5 seconds or more pass It might take time by the time the response returns because the command is processed in the projector Set the time out to ten seconds or more Not...

Страница 4: ...callback of POF command When REMOTE2 is effective ER401 is returned as a response callback Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 53h 03h Character A D Z Z O A S Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 41h 53h 03h Character O A S Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No No No No Yes Note This command is acceptable ...

Страница 5: ...he period when the command can be accepted Hexadecimal 02h 4Fh 54h 53h 3Ah 1 3 03h Character O T S 2 4 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 4Fh 53h 3Ah 1 03h Character A D Z Z O O S 2 Parameters 1 2 Shutter OFF Shutter ON Hexadecimal 30h 31h Character 0 1 Response Callback In the period when the command ...

Страница 6: ...O C U Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 43h 55h 03h Character O C U Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No Yes No Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 44h 03h Character A D Z Z O C D Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 43h 44h 03h Character O C D A...

Страница 7: ...TTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Note The acceptability conforms to the function allocated in FUNC1 Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 4Ch 03h Character A D Z Z O S L Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 53h 4Ch 03h Character O S L Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Note ...

Страница 8: ...h 49h 4Ch 3Ah 1 03h Character A D Z Z O I L 2 Parameters 1 2 FRONT F REAR F FRONT C REAR C Hexadecimal 30h 31h 32h 33h Character 0 1 2 3 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 49h 4Ch 3Ah 1 03h Character O I L 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No Yes Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 53h 3A...

Страница 9: ...esponse Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 45h 53h 03h Character O E S Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No No Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 44h 53h 3Ah Character A D Z Z O D S Hexadecimal 1 3 2Dh 5 7 03h Character 2 4 6 8 Parameters 1 2 3 4 5 6 mm of submemory number mm nn 1 2 01 02 03 04 Hexadeci...

Страница 10: ...h 39h 31h 30h 30h Character 0 9 8 0 9 9 1 0 0 Response Callback In the period when the command can be accepted Hexadecimal 02h 56h 43h 4Fh 3Ah 1 3 5 03h Character V C O 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No No Yes Yes Yes Note It is displayed in the menu by the value in which 50 is subtracted from the specified value Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56...

Страница 11: ...exadecimal 02h 56h 4Fh 52h 3Ah 1 3 5 03h Character V O R 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Notes When a parameter other than USER1 or USER2 is specified for COLOR TEMP ER401 is returned It is displayed in the menu by the value in which 128 is subtracted from the specified value Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 4Fh 47h 3Ah Charac...

Страница 12: ...er 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h Character 2 5 3 2 5 4 2 5 5 Response Callback In the period when the command can be accepted Hexadecimal 02h 56h 48h 52h 3Ah 1 3 5 03h Character V H R 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Note When a parameter other than USER1 or USER2 is specified for COLOR ...

Страница 13: ...ecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h Character 0 6 1 0 6 2 0 6 3 Response Callback In the period when the command can be accepted Hexadecimal 02h 56h 43h 4Eh 3Ah 1 3 5 03h Character V C N 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No No Yes Yes Yes Note It is displayed in the menu by the value in which 32 is subtracted from the specified value Hexadecimal 0...

Страница 14: ...ter V S R 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No No Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 4Eh 53h 3Ah Character A D Z Z V N S Hexadecimal 1 03h Character 2 Parameters 1 2 OFF ON or 1 2 3 Hexadecimal 30h 31h 32h 33h Character 0 1 2 3 Response Callback In the period when the command can be accepted Hexadecimal 02h 56h 4Eh 53h 3Ah 1 03h Characte...

Страница 15: ...3 0 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 41h 49h 3Ah 1 03h Character O A I 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah 1 03h Character A D Z Z O A I 2 Parameters 1 2 OFF 1 2 3 USER Hexadecimal 30h 31h 32h 33h 34h Character 0 1 2 3 4 Response Callback ...

Страница 16: ...ck In the period when the command can be accepted Hexadecimal 02h 4Fh 41h 49h 3Ah 44h 1 03h Character O A I D 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 53h 47h 3Ah Character A D Z Z V S G Hexadecimal 1 3 5 03h Character 2 4 6 Parameters 1 2 3 4 5 6 AUTO 1 AUTO 2 NTSC Hexadecimal 41h 54h 31h 41h 54h 32h 4Eh 5...

Страница 17: ...an be actually set changes according to the input signal and the input resolution setting etc Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 54h 56h 3Ah Character A D Z Z V T V Hexadecimal 1 3 5 03h Character 2 4 6 Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h 30h 30h 30h 32h Character 0 0 0 0 0 0 0 1 0 0 0 2 4093 4094 4095 Hexadecimal 34h 30h 39h 33h 34h 30h 39h 34h 34h 30h 39...

Страница 18: ...1 16 9 2 S4 3 2 THROUGH Hexadecimal 30h 31h 32h 33h 35h Character 0 1 2 3 5 HV FIT H FIT 1 Hexadecimal 36h 39h Character 6 9 Input route Except VIDEO S VIDEO Input signal SD DEFAULT 16 9 2 S4 3 2 THROUGH Hexadecimal 30h 32h 33h 35h Character 0 2 3 5 HV FIT H FIT 1 Hexadecimal 36h 39h Character 6 9 Input route Except VIDEO S VIDEO Input signal HD DEFAULT 4 3 1 S4 3 2 THROUGH Hexadecimal 30h 31h 33h...

Страница 19: ...98 999 Hexadecimal 39h 39h 37h 39h 39h 38h 39h 39h 39h Character 9 9 7 9 9 8 9 9 9 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 5Ah 56h 3Ah 1 3 5 03h Character O Z V 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No No Yes No Yes Notes When ASPECT is THROUGH ER401 is returned If INTERLOCKED is ON set it to OFF Hexadecimal 02h 4...

Страница 20: ...he input signal and the input resolution setting etc When less than number of display dots is specified ER402 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 44h 44h 3Ah Character A D Z Z V D D Hexadecimal 1 3 5 7 03h Character 2 4 6 8 Parameters 1 2 3 4 5 6 7 8 300 301 Hexadecimal 30h 33h 30h 30h 30h 33h 30h 31h Character 0 3 0 0 0 3 0 1 2045 2046 Hexadecimal 24h 30h 34h 35h 32h 30h 34h 36h C...

Страница 21: ...1h 31h 39h 39h 31h 32h 30h 30h Character 1 1 9 9 1 2 0 0 Response Callback In the period when the command can be accepted Hexadecimal 02h 56h 44h 4Ch 3Ah 1 3 5 7 03h Character V D L 2 4 6 8 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No No Yes Yes Yes Notes This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input In other cases ER401 is re...

Страница 22: ... 7 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 53h 4Bh 3Ah 1 3 5 7 03h Character O S K 2 4 6 8 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Notes When 0 is set into KEYSTONE ER401 is returned Even if KEYSTONE2 value is changed it might not operate according to KEYSTONE condition Hexadecimal 02h 41h 44h 5Ah 5Ah 3...

Страница 23: ...TTERN REMOTE2 Yes Yes Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 55h 3Ah Character A D Z Z D B U Hexadecimal 1 3 5 03h Character 2 4 6 Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 D10000 523 524 525 Hexadecimal 35h 32h 33h 35h 32h 34h 35h 32h 35h Character 5 3 8 5 3 9 5 4 0 DW10000 538 539 540 Hexadecimal 35h 33h 38h 35h ...

Страница 24: ...4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 52h 3Ah 1 3 5 03h Character A D Z Z D B R 2 4 6 Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 D10000 698 699 700 Hexadecimal 36h 39h 38h 36h 39h 39h 37h 30h 30h Character 6 9 8 6 9 9 7 0 0 DW10000 958 9...

Страница 25: ...L SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 4Ch 3Ah 1 03h Character A D Z Z O E D 2 Parameters 1 2 EDID1 EDID2 PC Hexadecimal 31h 32h Character 1 2 Response Callback In the period when the command can be accepted Hexadecimal 02h 44h 42h 4Ch 3Ah 1 03h Character O E D 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes...

Страница 26: ...SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Notes When AUX is specified for the parameter with incompatible input module installed in the slot ER401 is returned When AUX is specified for the parameter with no input module installed in the slot ER402 is returned When FRAME DELAY is set besides DEFAULT ER401 is returned If the same content as the channel set to sub w...

Страница 27: ...adecimal 39h 36h 39h 37h 39h 38h 39h 39h 31h 30h 30h Character 9 6 9 7 9 8 9 9 1 0 0 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Dh 53h 48h 3Ah 1 3 5 03h Character M S H 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Note When FRAME DELAY is set besides DEFAULT ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah ...

Страница 28: ...AME DELAY is set besides DEFAULT or RASTER POSITION is set besides 0 ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Dh 50h 48h 3Ah Character A D Z Z M P H Hexadecimal 1 3 5 7 03h Character 2 4 6 8 Parameters 1 2 3 4 5 6 7 8 D10000 674 673 672 Hexadecimal 2Dh 36h 37h 34h 2Dh 36h 37h 33h 2Dh 36h 37h 32h Character 6 7 4 6 7 3 6 7 2 672 673 674 Hexadecimal 2Bh 36h 37h 32h 2Bh 36h 37h 33h 2Bh 3...

Страница 29: ...4Ch 3Ah Character A D Z Z S S L Hexadecimal 1 03h Character 2 Parameters 1 2 OFF ON Hexadecimal 30h 31h Character 0 1 Response Callback In the period when the command can be accepted Hexadecimal 02h 53h 53h 4Ch 3Ah 1 03h Character S S L 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Note When FRAME DELAY is set besides DEFAULT ER401 is returned Hexadec...

Страница 30: ...es Yes Yes Note When FRAME DELAY is set besides DEFAULT ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 53h 53h 5Ah 3Ah Character A D Z Z S S Z Hexadecimal 1 3 5 03h Character 2 4 6 Parameters 1 2 3 4 5 6 10 11 12 13 14 Hexadecimal 31h 30h 31h 31h 31h 32h 31h 33h 31h 34h Character 1 0 1 1 1 2 1 3 1 4 96 97 98 99 100 Hexadecimal 39h 36h 39h 37h 39h 38h 39h 39h 31h 30h 30h Character 9 6 9 7 9 ...

Страница 31: ...es Yes Note When FRAME DELAY is set besides DEFAULT ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 53h 50h 48h 3Ah Character A D Z Z S P H Hexadecimal 1 3 5 7 03h Character 2 4 6 8 Parameters 1 2 3 4 5 6 7 8 D10000 674 673 672 Hexadecimal 2Dh 36h 37h 34h 2Dh 36h 37h 33h 2Dh 36h 37h 32h Character 6 7 4 6 7 3 6 7 2 672 673 674 Hexadecimal 2Bh 36h 37h 32h 2Bh 36h 37h 33h 2Bh 36h 37h 34h Charac...

Страница 32: ...mand can be accepted Hexadecimal 02h 50h 54h 50h 3Ah 1 03h Character P T P 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 No No Yes Yes Yes Yes Note When FRAME DELAY is set besides DEFAULT ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 54h 53h 44h 3Ah Character A D Z Z T S D Hexadecimal y1 y2 y3 y4 m1 m2 d1 D2 w 03h Character Parameters y1 y4 Year 4 digits m1 m2 Mont...

Страница 33: ...cter Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 50h 57h 03h Character A D Z Z Q P W Response Callback OFF Hexadecimal 02h 30h 30h 31h 03h Character 0 0 0 ON Hexadecimal 02h 30h 30h 31h 03h Character 0 0 1 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Hexadecimal ...

Страница 34: ... SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 4Fh 53h 03h Character A D Z Z Q O S Response Callback OFF Hexadecimal 02h 31h 03h Character ON Hexadecimal 02h 31h 03h Character 1 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes 2 86 Query Input Change 2 87 Query TEST PATTERN OFF White...

Страница 35: ...TE2 Yes No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 98 99 100 Hexadecimal 30h 39h 38h 30h 39h 39h 31h 30h 30h Character 0 9 8 0 9 9 1 0 0 Note The value in which 50 is added to the value displayed in the menu is returned as a response callback Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 54h 03h Character A D Z Z Q V T ...

Страница 36: ... 3 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h Character 2 5 3 2 5 4 2 5 5 Notes When a parameter other than USER1 or USER2 is specified for COLOR TEMP ER401 is returned The value in which 128 is added to the value displayed in the menu is returned as a response callback Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 4Fh 47h 03h Character A D Z Z Q O G Response Callback In the period when...

Страница 37: ...racter 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h Character 2 5 3 2 5 4 2 5 5 Note When a parameter other than USER1 or USER2 is specified for COLOR TEMP ER401 is returned Hexadeci...

Страница 38: ...SHUTTER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 1 2 3 Hexadecimal 30h 30h 31h 30h 30h 32h 30h 30h 33h Character 0 0 1 0 0 2 0 0 3 61 62 63 Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h Character 0 6 1 0 6 2 0 6 3 Note The value in which 32 is added to the value displayed in the menu is returned as a response callback Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 42h 03h ...

Страница 39: ...n the period when the command can be accepted Hexadecimal 02h 1 03h Character 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Parameters 1 2 OFF ON or 1 2 3 Hexadecimal 30h 31h 32h 33h Character 0 1 2 3 Notes When FRAME DELAY is set besides DEFAULT ER401 is returned During P IN P ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 41h 49h 03h Cha...

Страница 40: ...meters 5 6 7 8 OFF 1 2 3 Hexadecimal 30h 30h 30h 31h 30h 32h 30h 33h Character 0 0 0 1 0 2 0 3 60 61 62 63 Hexadecimal 36h 30h 36h 31h 36h 32h 36h 33h Character 6 0 6 1 6 2 6 3 Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 53h 47h 03h Character A D Z Z Q S G Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 5 03h Character 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL ...

Страница 41: ... 34h 30h 39h 33h 34h 30h 39h 34h 34h 30h 39h 35h Character 4 0 9 3 4 0 9 4 4 0 9 5 Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 54h 56h 3Ah Character A D Z Z Q T V Hexadecimal 31h 03h Character 1 Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 5 7 03h Character 2 4 6 8 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No No Yes No Yes Paramete...

Страница 42: ... Input signal NTSC VID AUTO PRI 4 3 1 16 9 2 S4 3 2 THROUGH Hexadecimal 30h 31h 32h 33h 35h Character 0 1 2 3 5 HV FIT H FIT 1 S1 AUTO 3 VID AUTO 3 Hexadecimal 36h 39h 32h 30h 33h 30h Character 6 9 2 0 3 0 Input route S VIDEO Input signal Except NTSC DEFAULT 4 3 1 16 9 2 S4 3 2 THROUGH Hexadecimal 30h 31h 32h 33h 35h Character 0 1 2 3 5 HV FIT H FIT 1 Hexadecimal 36h 39h Character 6 9 Input route ...

Страница 43: ...NDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No No Yes No Yes Parameters 1 2 3 4 5 6 50 51 52 Hexadecimal 30h 35h 30h 30h 35h 31h 30h 35h 32h Character 0 5 0 0 5 1 0 5 2 997 998 999 Hexadecimal 39h 39h 37h 39h 39h 38h 39h 39h 39h Character 9 9 7 9 9 8 9 9 9 Notes When ASPECT is THROUGH ER401 is returned Even if INTERLOCKED is ON the value of ZOOM H is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3B...

Страница 44: ...2 Yes No No Yes Yes Yes Parameters 1 2 3 4 5 6 7 8 300 301 Hexadecimal 30h 33h 30h 30h 30h 33h 30h 31h Character 0 3 0 0 0 3 0 1 2045 2046 Hexadecimal 32h 30h 34h 35h 32h 30h 34h 36h Character 2 0 4 5 2 0 4 6 Note This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input In other cases ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 54h 4Ch 03h Character A D...

Страница 45: ...Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h Character 2 5 3 2 5 4 2 5 5 Note This command is acceptable only when RGB1 or RGB2 is selected In other cases ER401 is returned Hexadecimal 02h ...

Страница 46: ...TER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 7 8 127 126 125 Hexadecimal 2Dh 31h 32h 37h 2Dh 31h 32h 36h 2Dh 31h 32h 35h Character 1 2 7 1 2 6 1 2 5 125 126 127 Hexadecimal 2Bh 31h 32h 35h 2Bh 31h 32h 36h 2Bh 31h 32h 37h Character 1 2 5 1 2 6 1 2 7 Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 4Ch 47h 03h Character A D Z Z Q L G Response Callback In the period when the command ...

Страница 47: ... Hexadecimal 35h 33h 38h 35h 33h 39h 35h 34h 30h Character 5 3 8 5 3 9 5 4 0 Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 4Ch 42h 03h Character A D Z Z Q L B Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 5 03h Character 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h...

Страница 48: ...e command can be accepted Hexadecimal 02h 1 3 5 03h Character 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 D10000 698 699 700 Hexadecimal 36h 39h 38h 36h 39h 39h 37h 30h 30h Character 6 9 8 6 9 9 7 0 0 DW10000 958 959 960 Hexadecimal 39h 35h ...

Страница 49: ... NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Parameters 1 2 3 4 5 6 7 8 0 h 1 h Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h Character 0 0 0 0 0 0 0 1 9998 h 9999 h Hexadecimal 39h 39h 39h 38h 39h 39h 39h 39h Character 9 9 9 8 9 9 9 9 Note It returns with 65535 five digits when LAMP RUNTIME cannot be obtained Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 53h 4Ch 03h Character A D Z Z Q...

Страница 50: ...xadecimal 02h 32h 03h Character 1 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 54h 4Dh 3Ah Character A D Z Z Q T M Hexadecimal 1 03h Character 2 Parameters 1 2 Intake air Exhaust air Optical module Hexadecimal 30h 31h 32h Character 0 1 2 Response Callback For 20 C Celsius Fahrenheit Hexadecimal 02h 2Dh 30h 32h ...

Страница 51: ... D Z Z Q S B Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 03h Character 2 4 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Parameters 1 2 3 4 When the sub memory is not used ER401 is returned 01 02 03 04 Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h Character 0 1 0 2 0 3 0 4 93 94 95 96 Hexadecimal 39h 33h 39h 34h 39...

Страница 52: ...R TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Parameters 1 2 OFF USER1 USER2 USER3 Hexadecimal 30h 31h 32h 33h Character 0 1 2 3 Note When FRAME DELAY is set besides DEFAULT ER401 is returned Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 49h 4Dh 03h Character A D Z Z Q I M Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 5 03h Character 2 4 6 Acceptability SECURITY ST...

Страница 53: ... 3 0 1 4 96 97 98 99 100 Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h Character 0 9 6 0 9 7 0 9 8 0 9 9 1 0 0 Parameters 11 12 13 14 15 16 H SIZE 10 11 12 13 14 Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h Character 0 1 0 0 1 1 0 1 2 0 1 3 0 1 4 96 97 98 99 100 Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h Character 0 ...

Страница 54: ...2Dh 36h 37h 34h 2Dh 36h 37h 33h 2Dh 36h 37h 32h Character 6 7 4 6 7 3 6 7 2 672 673 674 Hexadecimal 2Bh 36h 37h 32h 2Bh 36h 37h 33h 2Bh 36h 37h 34h Character 6 7 2 6 7 3 6 7 4 DW10000 926 925 924 Hexadecimal 2Dh 39h 32h 36h 2Dh 39h 32h 35h 2Dh 39h 32h 34h Character 9 2 6 9 2 5 9 2 4 924 925 926 Hexadecimal 2Bh 39h 32h 34h 2Bh 39h 32h 35h 2Bh 39h 32h 36h Character 9 2 4 9 2 5 9 2 6 Note When FRAME ...

Страница 55: ...1 3 0 1 4 96 97 98 99 100 Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h Character 0 9 6 0 9 7 0 9 8 0 9 9 1 0 0 Parameters 11 12 13 14 15 16 H SIZE 10 11 12 13 14 Hexadecimal 30h 31h 30h 30h 31h 31h 30h 31h 32h 30h 31h 33h 30h 31h 34h Character 0 1 0 0 1 1 0 1 2 0 1 3 0 1 4 96 97 98 99 100 Hexadecimal 30h 39h 36h 30h 39h 37h 30h 39h 38h 30h 39h 39h 31h 30h 30h Character 0...

Страница 56: ...ers 9 10 11 12 13 14 15 16 H POSITION D10000 674 673 672 Hexadecimal 2Dh 36h 37h 34h 2Dh 36h 37h 33h 2Dh 36h 37h 32h Character 6 7 4 6 7 3 6 7 2 672 673 674 Hexadecimal 2Bh 36h 37h 32h 2Bh 36h 37h 33h 2Bh 36h 37h 34h Character 6 7 2 6 7 3 6 7 4 DW10000 926 925 924 Hexadecimal 2Dh 39h 32h 36h 2Dh 39h 32h 35h 2Dh 39h 32h 34h Character 9 2 6 9 2 5 9 2 4 924 925 926 Hexadecimal 2Bh 39h 32h 34h 2Bh 39h...

Страница 57: ... of the week Mon 1 Tue 2 Wed 3 Thu 4 Fri 5 Sat 6 Sun 7 Set it by UTC Coordinated Universal Time Example Thursday June 29 2006 y1 y2 y3 y4 m1 m2 d1 D2 w Hexadecimal 32h 30h 30h 36h 30h 36h 32h 39h 34h Character 2 0 0 6 0 6 2 9 4 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 47h 54h 03h Character A D Z Z Q G T Res...

Страница 58: ...cter A D Z Z Q L S Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 03h Character 2 4 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Parameters 1 2 3 4 Extended Control Command Start STX ID Command Parameters End ETX 1 byte 1 byte 1 byte or 3 bytes Undefined length 1 byte 2 148 Query Model Series Name 2 149 Query Lam...

Страница 59: ...3F Group V 95 ID18 12 ID41 29 ID64 40 Group W 96 ID19 13 ID42 2A Group A 80 Group X 97 ID20 14 ID43 2B Group B 81 Group Y 98 ID21 15 ID44 2C Group C 82 Group Z 99 ID22 16 ID45 2D Group D 83 Hexadecimal 02h 1 B1h 7Ch 2 3 4 03h Remarks STX ID Command Parameters ETX Parameters 2 LENS SHIFT H LENS SHIFT V LENS FOCUS LENS ZOOM Hexadecimal 00h 01h 02h 03h Parameters 3 Slowly Normal Fast Home position He...

Страница 60: ...t air temperature is the specific value or higher It is less than the specific value 7 Low temperature error OPT Optical module DMD surroundings temperature is less than the specific value It is the specific value or higher 8 Lamp 1 operating time warning 9 Lamp 2 operating time warning 10 Lamp 3 operating time warning 11 Lamp 4 operating time warning Lamp cumulative usage time is the specific val...

Страница 61: ...diator fan 56 Fan error 9 Exhaust fan C 57 Fan error 10 Exhaust fan L 58 Fan error 11 Exhaust fan R 59 Fan error 12 R DMD fan 60 Fan error 13 Liquid cooling pump G 61 Fan error 14 Liquid cooling pump B 62 Fan error 15 Color prism fan 63 Fan error 16 Lamp prism fan 64 Fan error 17 Ballast fan 2 65 Fan error 18 Ballast fan 4 Fan normal operation 66 Shutter error Shutter error Shutter ON OFF 67 Dynam...

Страница 62: ...n retry 9 108 IIC communication retry 10 109 IIC communication retry 11 110 IIC communication retry 12 111 IIC communication retry 13 112 IIC communication retry 14 113 IIC communication retry 15 114 IIC communication retry 16 115 A P C Board uninitialization A P C Board initialization 116 FM R test failure 117 FM G test failure 118 FM B test failure RDRAM test error POWER ON 119 FPGA1 setting err...

Отзывы: