22/62
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 4Bh 53h 3Ah
Character
A D Z Z ; O K S :
Hexadecimal *1 *3 *5 *7 03h
Character
*2 *4 *6 *8
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
127
126
125
Hexadecimal 2Dh 31h 32h 37h 2Dh 31h 32h 36h 2Dh 31h 32h 35h
Character
1 2 7
1 2 6
1 2 5
+125 +126 +127
Hexadecimal 2Bh 31h 32h 35h 2Bh 31h 32h 36h 2Bh 31h 32h 37h
Cha 1 2 5 + 1 2 6 + 1 2 7
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h
4Fh
4Bh
53h
3Ah *1 *3 *5 *7 03h
Character
O K S : *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO
SIGNAL SHUTTER TEST
PATTERN REMOTE2
No No Yes Yes
Yes
Yes
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 4Bh 3Ah
Character
A D Z Z ; O S K :
Hexadecimal *1 *3 *5 *7 03h
Character
*2 *4 *6 *8
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
127
126
125
Hexadecimal 2Dh 31h 32h 37h 2Dh 31h 32h 36h 2Dh 31h 32h 35h
Character
1 2 7
1 2 6
1 2 5
+125 +126 +127
Hexadecimal 2Bh 31h 32h 35h 2Bh 31h 32h 36h 2Bh 31h 32h 37h
Cha 1 2 5 + 1 2 6 + 1 2 7
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h
4Fh
53h
4Bh
3Ah *1 *3 *5 *7 03h
Character
O S K : *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO
SIGNAL SHUTTER TEST
PATTERN REMOTE2
No No Yes Yes
Yes
Yes
Notes:
• When 0 is set into KEYSTONE, ER401 is returned.
• Even if KEYSTONE2 value is changed, it might not operate according to KEYSTONE condition.
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 4Ch 49h 3Ah
Character
A D Z Z ; V L I :
Hexadecimal *1 *3 *5 *7 03h
Character
*2 *4 *6 *8
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
127
126
125
Hexadecimal 2Dh 31h 32h 37h 2Dh 31h 32h
36h
2Dh
31h
32h
35h
Character
1 2 7
1 2 6
1 2 5
+125 +126
+127
Hexadecimal
2Bh
31h 32h 35h 2Bh 31h 32h 36h 2Bh 31h 32h 37h
Character
+ 1 2 5 + 1 2 6 + 1 2 7
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h
56h
4Ch
49h
3Ah *1 *3 *5 *7 03h
Character
V L I : *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO
SIGNAL SHUTTER TEST
PATTERN REMOTE2
No No Yes Yes
Yes
Yes
Notes:
• When 0 is set into KEYSTONE, ER401 is returned.
• Even if LINEARITY value is changed, it might not operate according to KEYSTONE condition.
2.55. KEYSTONE
2.56. KEYSTONE2
2.57. LINEARITY