51/51
Bit Name
Description
Condition
of
Clear Bit
bit15
Warning of optical
module low temperature
The ambient temperature in the place of use may be 0°C or lower. If
the temperature inside this projector does not rise within 5 minutes after the
turning on the lamp, the shutdown occurs.
• Becomes
higher
than the
warning
release
temperatur
e during
power-on.
• Power ON
bit14
Warning of optical
module high temperature
bit13
Warning of intake air
high temperature
bit12
Warning of exhaust air or
lamp surroundings high
temperature
The temperature inside this projector has become high. If the temperature
rises any further, the shutdown occurs.
• The ventilation holes may be closed.
• The ambient temperature in the place of use may be too high.
• The air filter may accumulate dust.
• Becomes
lower than
the
warning
release
temperatur
e during
power-on.
• Power ON
bit11
For test
The value is undefined.
MAIN
POWER ON
bit10
For extension
The value is undefined.
—
bit09
For extension
The value is undefined.
—
bit08
For extension
The value is undefined.
—
bit07
Lamp 2 ON time error
Lamp 2 reset
bit06
Lamp 1 ON time error
It becomes a period when the lamp unit is replaced. Prepare a new lamp
unit. The shutdown will occur within 200 hours.
Lamp 1 reset
bit05
For extension
The value is undefined.
—
bit04
For extension
The value is undefined.
—
bit03
For extension
The value is undefined.
—
bit02 Color
wheel
rotation
error
The color wheel and/or color wheel drive circuit is abnormal. It is a
breakdown when not recovering even if the power is turned on again.
Power ON
bit01
Cover open error
Does the lamp unit cover open?
Close the
lamp unit
cover and
turn on MAIN
POWER.
bit00
For extension
The value is undefined.
Parameters 2 (*6, *7, *8, *9)