5/51
2. Basic Control Command
Explanatory notes
Yes: Enable
No: Disable
2.1. Power ON (Lamp ON)
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
50h
4Fh
4Eh
03h
Character
A
D
Z
Z
;
P
O
N
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included)
Hexadecimal
02h
50h
4Fh
4Eh
03h
Character
P
O
N
Acceptability
SECURITY
STNDBY
NO SIGNAL
SHUTTER
FREEZE
TEST PATTERN
REMOTE2
Yes
Yes
Yes
Yes
Yes
Yes
(Yes)
Note:
• When you confirm whether to have succeeded in power-on, confirm it by QPW (query power condition) command after
receiving the callback of PON command.
• REMOTE2 is given to priority. Calls back ER402 when the parameter is different from the setting of REMOTE2.
2.2. Power
OFF
(Standby)
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
50h
4Fh
46h
03h
Character
A
D
Z
Z
;
P
O
F
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included)
Hexadecimal
02h
50h
4Fh
46h
03h
Character
P
O
F
Acceptability
SECURITY
STNDBY
NO SIGNAL
SHUTTER
FREEZE
TEST PATTERN
REMOTE2
Yes
Yes
Yes
Yes
Yes
Yes
(Yes)
Note:
• When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after receiving
the callback of POF command.
• REMOTE2 is given to priority. Calls back ER402 when the parameter is different from the setting of REMOTE2.
2.3. FREEZE
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
4Fh
46h
5Ah
3Ah
*1
03h
Character
A
D
Z
Z
;
O
F
Z
:
*2
Parameters (*1, *2)
Freeze OFF
Freeze ON
Hexadecimal
30h
31h
Character
0
1
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
4Fh
46h
5Ah
3Ah
*1
03h
Character
O
F
Z
:
*2
Acceptability
SECURITY
STNDBY
NO SIGNAL
SHUTTER
FREEZE
TEST PATTERN
REMOTE2
No
No
No
No
Yes
Yes
Yes
2.4. AUTO
SETUP
Hexadecimal
02h
41h
44h
5Ah
5Ah
3Bh
4Fh
41h
53h
03h
Character
A
D
Z
Z
;
O
A
S
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h
4Fh
41h
53h
03h
Character
O
A
S
Acceptability
SECURITY
STNDBY
NO SIGNAL
SHUTTER
FREEZE
TEST PATTERN
REMOTE2
No
No
No
No
Yes
Yes
Yes
Note:
• This command is acceptable only when analog RGB signals (except a part of high dot clock signals) or DVI signals are
input. In other cases, ER401 is returned.