4/51
Response (Callback) of the basic control command
In the period when commands can be accepted
Differs according to each command.
In the period when commands cannot be accepted
Hexadecimal
02h
45h
52h
34h
30h
31h
03h
Character
E
R
4
0
1
In case of the parameter error or REMOTE2 effective
Hexadecimal
02h
45h
52h
34h
30h
32h
03h
Character
E
R
4
0
2
Attention:
• No command may be sent or received for 10 to 60 seconds after the lamp starts lighting. Try sending any
command after that period has elapsed.
• When sending several commands, be sure to wait for a response from the projector, and send the next
command after 0.5 seconds or more pass.
• It might take time by the time the response returns because the command is processed in the projector.
Set the time-out to ten seconds or more.
Note:
• This projector will respond to the computer only in the following cases:
If the sent ID coincides with the projector ID,
VPS SYSTEM in RS232C settings of this projector is MASTER and the sent ID is ALL, or
If Group (A
Z) of the sent ID coincides with GROUP in RS232C settings of this projector and GROUP in
RS232C settings of this projector is MASTER.