152
5.1.4.2.
Tonal Signal
This Service Mode is used to check the tonal signal output. Signals can be output to the line using the
following procedure.
Tonal Signal Table
Service Mode 4 - Tonal Signal
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “4”.
5
Press “2” or
use “V” or “/\ “ to scroll to the desired Modem Test.
6
Press “START”.
7
Enter the signal number (1-7) to select the binary
signal.
8
Press "CLEAR" to end the signal generation. To select
another signal, repeat step 6.
9
Press "STOP" twice to return to standby.
Number
Signals
1
462 Hz
2
1080 Hz
3
1100 Hz
4
1300 Hz
5
1650 Hz
6
1850 Hz
7
2100 Hz
MMM-DD 10:58 00%
SET MODE (1-8)
SERVICE MODE
SIGNAL TEST
TONAL TEST
IDLE (ENTER 1-7)
1080Hz
IDLE (ENTER 1-7)
MMM-DD 10:58 00%
Содержание Panafax UF-4000
Страница 4: ...4 ...
Страница 8: ...8 memo ...
Страница 21: ...21 1 4 Control Panel For USA and Canada UF 490 UF 4000 ...
Страница 22: ...22 For Other Destinations UF 490 UF 4100 UF 4100 ABBR ...
Страница 44: ...44 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Страница 70: ...70 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Страница 72: ...72 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...
Страница 136: ...136 MMM DD YYYY 10 55 VERSION UF 0000 AAV1xxxxAU MEMORY SIZE MB TX RX PRT CPY 000017 000005 000036 000007 SHIPMENT SET ...
Страница 232: ...232 801 803 802 Fig 8 Cartridge Unit K A C D E F G H I J B 8 1 3 4 5 6 7 2 2 2 ...
Страница 250: ...250 memo ...
Страница 280: ...280 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For USA Canada 2 2 Model UF 490 UF 4000 ...
Страница 282: ...282 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For Other Destinations 2 2 Model UF 490 UF 4100 ...
Страница 283: ...memo ...
Страница 284: ...DZZSM00309 ...