116
494
RCV
C
Interval between two EOLs was
more than 10 sec. when receiver
received message data.
Transmitter is defective.
Line quality is poor. (EOL is damaged
due to line noise)
SC PCB is defective.
495
XMT
RCV
C
During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
SC PCB is defective.
496
XMT
C
CS of modem is not able to turn
ON.
SC PCB is defective.
501
XMT/
RCV(V.34)
B
Remote unit does not have
compatible Modem.
502
XMT/
RCV(V.34)
B, C, D During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
SC PCB is defective.
503
XMT/
RCV(V.34)
B, C, D CS of modem is not able to turn
ON during training.
SC PCB is defective.
Line is disconnected.
504
RCV/V.34
(Polling)
B
Polling is rejected from the remote
station.
No polling original is set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling original is set.
540
XMT ECM
B
No response after transmitting 3rd
CTC or DCN received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd
EOR or received DCN.
Line is faulty.
SC PCB abnormal.
542
XMT ECM
D
No response to the 3rd RR
transmitted or received DCN.
Remote unit is abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without
MCF.
Remote unit is abnormal.
544
XMT ECM
D
Stopped Transmission after EOR
Transmission.
Line is faulty.
SC PCB abnormal.
550
RCV ECM
C
Timer between frames in phase C
has elapsed.
Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving
EOR.
Faulty line.
555
RCV ECM
D
Transmitted PIN after receiving
EOR.
Faulty line and Operator Call requested
by RX side.
570
RCV
B
Password or machine code did not
match during remote diagnostic
communication.
571
XMT
B
Remote unit did not have the
remote diagnostic function.
580
XMT
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
581
XMT
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Содержание Panafax UF-4000
Страница 4: ...4 ...
Страница 8: ...8 memo ...
Страница 21: ...21 1 4 Control Panel For USA and Canada UF 490 UF 4000 ...
Страница 22: ...22 For Other Destinations UF 490 UF 4100 UF 4100 ABBR ...
Страница 44: ...44 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Страница 70: ...70 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Страница 72: ...72 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...
Страница 136: ...136 MMM DD YYYY 10 55 VERSION UF 0000 AAV1xxxxAU MEMORY SIZE MB TX RX PRT CPY 000017 000005 000036 000007 SHIPMENT SET ...
Страница 232: ...232 801 803 802 Fig 8 Cartridge Unit K A C D E F G H I J B 8 1 3 4 5 6 7 2 2 2 ...
Страница 250: ...250 memo ...
Страница 280: ...280 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For USA Canada 2 2 Model UF 490 UF 4000 ...
Страница 282: ...282 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For Other Destinations 2 2 Model UF 490 UF 4100 ...
Страница 283: ...memo ...
Страница 284: ...DZZSM00309 ...