http://cxema.ru
PROCEDURES
FIP DISPLAY
Press the FF and EJECT Keys
simultaneously for 3 seconds.
Press the FF and EJECT Keys
simultaneously twice.
Press the EJECT key for 3
seconds.
Press the CH UP key once.
Insert the Alignment cassette
tape. (PAL:VFJ8125H3F)
When the sequence of the automatical adjustment has
been terminated, the following action has been made.
*SUCCEED: The cassette tape is ejected.
*ERROR : The "F2"is displayed on the FIP.
(Check the Servo/Syscon circuit and Cylinder
unit.)
Release the Service mode by pressing the EJECT and
FF keys simultaneously in 6 times until the FIP
becomes normal indication.
Fig. E3
3.3.5. AI FUNCTION ADJUSTMENT (AUTOMATIC)
PROCEDURES
FIP DISPLAY
Press the FF and EJECT Keys
simultaneously for 3 seconds.
Press the FF and EJECT Keys
simultaneously twice.
Press the EJECT key for 3
seconds.
Press the CH UP key in 3 times.
Insert the blank cassette tape.
(The adjustment is automatically
started.)
When the sequence of the automatical adjustment has
been terminated successfully, the VCR goes to STOP
mode.