39
7-2. MEMORY OF THE SELF-DIAGNOSIS HISTORY AND THE SUPPLEMENTARY DATA
This is effective only in Service Mode 3, 4, 5.
(1) Error Number and Supplementary Data
The Supplementary Data for each Error number are memorized.
Supplementary Data
Memory No.
(Error No.)
Reason
Data 1
Data 2
2*
(Refer to
Note:)
An error while the PG Automatic
Adjustment
VCR mode
No Data
80
An exceptional ejection depends on a Error
VCR mode
Reason of Ejection
18
Detection of T-reel lock during the
constant tape running
VCR mode
Tape position
17
Detection of S-reel lock during the
constant tape running
VCR mode
Tape position
16
Detection of the Cylinder lock during the
constant rotation
VCR mode
Tape position
15
S-reel pulse cannot be detected when a
cassette tape is inserted.
(Error of the S-reel system or the Capstan
system.)
VCR mode
Counted value of S-reel pulse
14
An exceptional detection of the DOWN
position during the unloading.
No Data
No Data
08
The recording circuit is operated in except
for REC mode.
VCR mode
No Data
07
The recording circuit can not be operated in
REC mode.
VCR mode
No Data
06
Mechanism lock during the Cassette-up.
VCR mode
Stand-by position
05
S-reel pulse cannot be detected when a
cassette tape is inserted.
(Error of the S-reel system or the Capstan
system.)
VCR mode
Tape position
04
Mechanism lock during unloading
VCR mode
Stand-by position
03
Mechanism lock during without the
unloading and the cassette-up.
VCR mode
Stand-by position
02
The CAP FG could not be detected.
VCR mode
No Data
01
The cylinder could not be started.
(Error of the cylinder or the cylinder driver.)
VCR mode
No Data
11
Cylinder clogs during the PLAY mode.
VCR mode
No Data
10
Dew detection.
VCR mode
No Data
* Details of “VCR mode” of the Supplementary Data (These values are hexadecimal indication)
0: STOP, 1: EJECT, 2: REW, 3: FF, 4:REV, 5: CUE, 6: SLOW, 7: POWEROFF, 8: PLAY, 9: STIL,
A: REC, B: REC PAUSE, C: ADUB, D: ADUB PAUSE, E: INSERT, F: INSERT PAUSE
Note:
2* is as follows.
F20
NG1 in the PG Shifter Automatic Adjustment
(The cylinder rotation is unstable during the automatic adjustment.)
F21
NG2 in the PG Shifter Automatic Adjustment
(The vertical sync signal is lacked while over 5 seconds on the alignment tape.)
F22
NG3 in the PG Shifter Automatic Adjustment
(The installing position of Heads to the cylinder is our of specification.
F23
NG4 in the PG Shifter Automatic Adjustment
(The servo is not locked to the cylinder for more than 10 sec.)
(Sample)
Содержание NV-HV61EE
Страница 20: ...3 1 2 DETAIL OF DISASSEMBLY METHOD 1 REMOVAL OF THE TOP PANEL Remove 2 Screws A Remove 2 Screws B Fig D2 20 ...
Страница 21: ...2 REMOVAL OF THE BACK PANEL Remove 2 Screws C Remove Screw D Unlock 4 Tabs E Fig D3 21 ...
Страница 29: ...10 2 CASING PARTS SECTION 29 ...
Страница 30: ...10 3 PACKING PARTS SECTION 30 ...
Страница 31: ...11 REPLACEMENT PARTS LIST 31 ...
Страница 41: ...C4537 ECJ2VC1H560G CHIP CAPACITOR 41 ...
Страница 44: ...D2002 B0AAED000003 DIODE 44 ...
Страница 47: ...Q1152 2SC3311ASA TRANSISTOR 47 ...
Страница 49: ...R1502 ERJ3GEYJ273V CHIP RESISTOR 49 ...
Страница 54: ...W519 ERJ3GEY0R00V CHIP JUMPER 54 ...
Страница 109: ...4 1 3 PARTS NAME OF R4 MECHANISM Fig M2 ...
Страница 139: ...34 ...