- 16 -
NR-BY551 / NR-BY601
To confirm when compressor is operating.
NO
NO
NO
Does the “Energy Saving” turn off, “Quick
Freezing” turn off and “Freezer Control”
LED “MAX” blinking?
Does the “Energy Saving” turn off, “Quick
Freezing” turn off and “Freezer Control”
LED “MIN” blinking?
Does frost adhere to evaporator much?
10
11
12
YES
•
Gas leakage at high pressure side.
• Poor compression.
• Defect of control PCB.
YES
•
Gas leakage at low pressure side.
• Defect of control PCB.
•
Gap of door.
• Defect of control PCB.
YES
Содержание NR-BY551SS
Страница 17: ... 17 10 SCHEMATIC DIAGRAM 10 1 Wiring Diagram NR BY551MS NR BY551 NR BY601 ...
Страница 18: ... 18 NR BY551 NR BY601 10 2 Wiring Diagram NR BY551SS ...
Страница 19: ... 19 10 3 Wiring Diagram NR BY551VS XS NR BY551 NR BY601 ...