NR-BW414 / NR-BW464
- 23 -
12.2 NR-BW414VS, NR-BW414XN, NR-BW464VS, NR-BW464XN (Inverter)
•
PC Cooling not enough / Ice forming
1. Symptom of the problem
PC less cooling.
2. Cause
Fan motor does not work due to ice forming,
stuck to fan motor area.
Fan motor can’t blow cold air.
Then PC temperature is insufficient.
3. Detail of countermeasure / TI No. : REF 12-02
Protect ice-forming to fan motor areas.
1) Add new insulation plate : Kit Part No. WS-08x100x250MM 1 pcs. to INS. rear of cover coil.
2) Add new insulation plate : Kit Part No. WS-08x100x250MM 1 pcs. to rear side of coil EVP.
3) Add deflector Part No. BF161020 1 pcs to tube of coil EVP.
4) Replace Pas-control Part No. CNRBG-170061.
** Refer to item instruction of the modification in your field. (Page 24-26)
5. Instruction of the modification in your field
•
Estimate cause
Circulated air from PC doesn’t pass into evaporator, pass on only surface.
Therefore circulated air doesn’t become to dried, then circulated air form FC is provided with humidity and
comes out in fan motor area. This area is very cold, so that humidity in circulated air will become ice and
ice forming.
4. Description part addition / compatibility
Status
Ref.
Part Name
Description
Q’ty
New
Replace
1
Countermeasure kit
CNRBG170061KT
1 Unit
Insulation plate
WS-08x100x250MM
2 Pcs
2
Cable tie
N/A
1 Pcs
3
Deflector
BF161020
1 Pcs
4
PAS-B41MV4 (control)
CNRBG-170061
1 Pcs
DWG internal side
of coil EVP.
Suspect air retun from
PC accumulation
to this area.
Suspect air retun from
PC accumulation
to this area.
Cover coil
Coil EVP.
Inner Liner