background image

Order No. PHAT090301C3

(Revision : Nov. 2012)

Service Manual

Refrigerator

NR-BW414MN, NR-BW414SS, NR-BW414SN, NR-BW414SW

NR-BW414VS, NR-BW414XN / NR-BW464VS, NR-BW464XN

Product Colour

Silver (SL)

Champagne (SN)

Stainless (ST)

Destination

Malaysia, Hong Kong

Singapore, India, Vietnam

RBD, Indonesia, Philippines

PGF, GULF (Gen)

© Panasonic Appliances (Thailand) Co., Ltd. 2012.
All rights reserved. Unauthorized copying and
distribution is a violation of law.

There are special components used in this equipment which are important for safety. These parts are marked by        in the
Schematic Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical
parts should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the 
original design without permission of manufacturer.

IMPORTANT SAFETY NOTICE

WARNING

The service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a
product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the product or products dealt within this service information by anyone else could result in serious
injury or death.

CFCs have been used in refrigerant as refrigerator and the insulation materials for many years. But it is now
known that these compounds which once seemed so ideal for use as cleaning agents and in refrigeration
systems, destroy the earth’s ozone layer as a result, an international body decided on a total worldwide ban of 
harmful CFCs by the end of 1995.

NR-BW414MN
NR-BW414SS
NR-BW414SN

NR-BW414SS
NR-BW414SW
(WG, AE)

NR-BW414VS
NR-BW414XN

NR-BW464VS
NR-BW464XN

Содержание NR-BW414MN

Страница 1: ...anufacturer IMPORTANT SAFETY NOTICE WARNING The service information is designed for experienced repair technicians only and is not designed for use by the general public It does not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional t...

Страница 2: ...frigerator Instruction Guidelines 8 Troubleshooting Guide 8 1 Not cool at all Both PC and FC compressor does not operate 8 2 Cool not enought Both PC and FC compressor operates 9 Schematic Diagram 9 1 Wiring Connection NR BW414MN NR BW414SS SN SW 9 2 Wiring Connection NR BW414VS NR BW414XN NR BW464VS NR BW464XN 10 Disassembly Instruction 10 1 Cover Control 10 2 PAS Control 11 Repairing Procedure 1...

Страница 3: ... 3 minutes at least for discharging capacitor Check safety after repairing Check the screws parts lead wires to take in place Check the repairing portion whether circumferential parts are damaged or not Check insulation resistance between supply plug and earth When install refrigerator check condition of supply cord and plug Wipe off the dust on plug Cutting and seal the electric device carefully ...

Страница 4: ...37M4 MM6 8V34 230V 176W MM6 4343 220V 183W MM3 20DCW 5TM232NHBYY 53 No use 4µF 400V 1 Ambient Temp over 34 C 8h 1 Ambient Temp over 34 C 7h 2 Ambient Temp 23 C 33 C 8h 2 Ambient Temp 23 C 33 C 7h 3 Ambient Temp under 22 C 13h 3 Ambient Temp under 22 C 13h 4 Power ON 4h add 4 Power ON 6h add DC 9V 1 53W Door Switch Fan Motor PTC Relay Fan Blade Type Type Rating Type Rating Defrost Sensor DFC Type R...

Страница 5: ...ch D3D 121 S P S T 250V 0 5A Ø 90 mm prop fan Box Type DC 14V 1 54W E14 22 240V 10W No use MM6 8V34 230V 176W MM3 20DCW No use NTC B 3819K 2 R10 3 899KΩ 3 NTC B 3850K 2 R20 18 9KΩ 1 8 250V 10A 73 C PAS B41MV4 1 Ambient Temp over 34 C 8h 2 Ambient Temp 23 C 33 C 8h 3 Ambient Temp under 22 C 13h 4 Power ON 4h add Fan Motor Fan Blade PTC Relay Type Rating Type Type Rating Type Rating Control Board De...

Страница 6: ...r Load Temperature C C C C t3 C Vegetable Crisper Temperature PC Door Shelf Upper Temperature C Egg Tray Temperature PC Door Shelf Bottom Temperature 1 0 2 5 3 5 2 5 7 0 2 5 22 0 2 5 19 5 2 5 15 0 2 5 Running Ratio 85 15 75 15 Power Consumption KWh Day 1 8 60 15 7 0 2 5 4 5 2 5 5 0 2 5 3 Thermostat Dial Setting 2 1 3 3 NR BW464VS NR BW464XN Mean Fresh Food Compartment Temperature Mean Freezer Load...

Страница 7: ...pressor Normal operating 8 Does system protection cycle for 333 times 9 IC orders to stop compressor completely YES YES NO YES Normal operating IC continues to stop compressor until 1 hour IC indicates Self diagnosing sign NO NO YES 7 After 1 hour SYSTEM PROTECT CONTROL CYCLE 1st time OPERATE each 7min X 10 times COMPRESSOR 1hour STOP OPERATE each 7min X 10 times SYSTEM PROTECT CONTROL CYCLE 333rd...

Страница 8: ...op compressor occure 10 times within 2 min 5 IC cancels to stop compressor Normal operating 7 Does system protection cycle for 333 times 8 IC orders to stop compressor completely YES NO YES SYSTEM PROTECT CONTROL CYCLE 1st time OPERATE each 7min X 10 times COMPRESSOR 1hour STOP OPERATE each 7min X 10 times SYSTEM PROTECT CONTROL CYCLE 333rd time STOP COMPRESSOR NO YES NO Normal operating IC contin...

Страница 9: ...pply voltage if it is 180V AC 4 IC cancels to stop compressor Normal operating 5 After restarting does Stop compressor occure 10 times within 2 min 6 IC cancels to stop compressor Normal operating YES NO NO 7 After 1 hour NO YES YES Normal operating IC continues to stop compressor until 1 hour IC indicates Self diagnosing sign IC continues to stop compressor until 1 hour IC indicates Self diagnosi...

Страница 10: ...TC thermistor Break short of ATC thermistor Blinking Turn on None Abnormal of FC fan motor Break lock of FC fan motor Abnormal revolution of FC fan motor Turn on Turn on None Abnormal of Defrost heater in FC Break short of Defrost heater Turn on None None Abnormal of INV compressor Operate protector of IPM lock Operate protector of voltage dropping Operate protector of over voltage Turn on Blinkin...

Страница 11: ...ns ON Press the ENERGY SAVING button again to stop the operation Green light turns OFF 6 4 About energy saving Deodorizing function reduces Interior temperature gets slightly higher Frequent opening of the doors raise the interior temperature Higher interior temperature automatically activates normal operation on a temporary basis When the ENERGY SAVING is activated during QUICK FREEZING the ENERG...

Страница 12: ...around the refrigerator cabinet are helping to prevent Sweating on the outer surface of the cabinet without consuming the energy This will make the outer wall of the refrigerator gets warm and is not a malfunction 9 Drinking water bottles beverage bottles such as soft drink and fruit juice should be seal closely to prevent odor gets into the bottles Before calling for servicing please check as fol...

Страница 13: ...S NO NO YES NO YES YES YES YES YES NO NO NO NO 8 Does the Energy Saving turn off Quick Freezing turn off and Freezer Control LED MIN blinking Check power supply ex Connect Power cord in inlet ex Check ELCB Defect of over load relay ex Does Fuse blow Check Control PCB ex Does Fuse blow ex Defect of IC IC205 Diode BD201 etc Defect of Control PCB Defect PC door switch Defect of Control PCB Communicat...

Страница 14: ...r connection between FC fan motor and IC1 on PCB Short of DFC thermistor Poor connection between DFC thermistor and IC1 on PCB Break of DFC thermistor Defect of PCB as like as defect of relay etc Break of DFC thermistor Poor connection between FCC thermistor and IC1 on PCB YES 4 Does Energy Saving turn off and Quick Freezing blinking 7 Does Energy Saving turn on and Quick Freezing turn off YES NO ...

Страница 15: ...ezer Control LED MAX blinking 12 Does Energy Saving turn off Quick Freezing turn off and Freezer Control LED MIN blinking Defect of communication circuit and EEPROM circuit of control PCB Plug out and after 7 minute plug in again Gap of door Defect of control PCB Gas of leakage at low pressure side Defect of control PCB YES Gas leakage at high pressure side Poor compression Defect of control PCB ...

Страница 16: ...NR BW414 NR BW464 16 9 SCHEMATIC DIAGRAM 9 1 Wiring Connection NR BW414MN NR BW414SS SN SW 220V 240V 50Hz ...

Страница 17: ...NR BW414 NR BW464 17 9 2 Wiring Connection NR BW414VS NR BW414XN NR BW464VS NR BW464XN ...

Страница 18: ...Cover Control and push it loose as Fig 1 Then use another hand lift it up slowly as Fig 2 Take out PAS Control by use screwdriver put at hook of Cover Control and push it up as Fig 3 After take out PAS Control loose at the first hook use screwdriver push at next hook as Fig 4 While push the hook have to use another hand pull PAS Control up Fig 1 Fig 2 Fig 3 Fig 4 ...

Страница 19: ... than 1 0 mm To take off the 2 screws of hinge bottom To add shim size 1 mm with hinge bottom and re ass y to FC Door To checking both PC and FC door alignment OK Note 1 Add shim 2 pcs Condition FC Door over lab actual 1 5 3 0 mm 2 Add shim 3 pcs Condition FC Door over lab actual more 3 0 mm Fig 2 Fig 4 Fig 3 Fig 6 Fig 5 Fig 8 Fig 7 ...

Страница 20: ...G 166465 Refer to page 21 22 for how to modify countermeasure in your field 5 Instruction of the modification in your field Estimate cause Circulated air from PC doesn t pass into evaporator pass on only surface Therefore circulated air doesn t become to be dried then circulated air form FC is provided with humidity and comes out in fan motor area This area temperature is very cold so that humidit...

Страница 21: ...er Insulation plate Insulation plate Cover coil Coil EVP Inner Liner Cover coil Add insulation on rear of Cover coil Make hole before re assemble support coil Assemble support coil to inner liner Cable tie lock with tube of coil EVP Ref 2 Add cable tie 1 pcs Add insulation on rear of Cover coil Deflector at tube coil 1pcs Romve coil EVP from support coil Remove Deflector Remove screw of support co...

Страница 22: ...e operated 7 After assemble part to unit completed please check whether function is OK as follows 1 Lamp is on 2 Compressor is working 3 Fan motor is on and working Countermeasure No 2 2 1 To add one deflector Countermeasure No 3 3 1 Pas control CNRBG 166465 replace New PCB control have circle marking on top of Capacitor spec 450V Add deflector 1 pcs DWG Deflector have 1 pcs J1 J2 ...

Страница 23: ...er to item instruction of the modification in your field Page 24 26 5 Instruction of the modification in your field Estimate cause Circulated air from PC doesn t pass into evaporator pass on only surface Therefore circulated air doesn t become to dried then circulated air form FC is provided with humidity and comes out in fan motor area This area is very cold so that humidity in circulated air wil...

Страница 24: ...r liner Insulation plate Insulation plate Cover coil Coil EVP Inner Liner Cover coil F Add insulation plate Make few hole before re assemble support coil to inner liner Assemble support coil to inner liner Ref 2 Cable tie 1 pcs lock with tube of coil EVP Ref 2 Add cable tie 1 pcs Add Insulation plate to rear of Coil EVP Deflector at tube coil 1pcs Romve coil EVP Remove Deflector for empty Remove s...

Страница 25: ... to unit completed please check whether function as follows 1 Lamp is on 2 Compressor is working 3 Fan motor is on and working Countermeasure No 2 2 1 To add one deflector Countermeasure No 3 3 1 Pas B41MV4 Control to replace DWG Deflector have 1 pcs Ref 3 Add deflector 1 pcs Ref 3 Addition deflector Part no BF161020 Note Dimension not to be same master F05 Ref 4 Replace new PCB 1 pcs Mark F05 ...

Страница 26: ...r e Push Freezer Control hold to 5 sec Then release your finger f Close both PC FC door g Push Quick Freezing 1 time Then release your finger h Then to check compressor will be stop and heater defrost will be function d Push Freezer Control 1 time Then release your finger c Push Quick Freezing 1 time Then release your finger ...

Страница 27: ...1 17 18 16 10 20 21 19 22 43 49 48 47 46 45 45 1 41 44 42 33 51 52 53 60 61 62 63 64 65 54 55 56 57 58 59 66 67 50 32 31 30 35 34 12 13 14 15 For NR BW414MN SS SN SW For Inverter only For PGF GULF For NR BW414MN SS For Inverter only NR BW414MN SS 20 1 64 23 24 26 27 28 29 36 38 40 37 39 25 95 EXCEPT SN MODEL EXCEPT SN MODEL ...

Страница 28: ...414 NR BW464 28 13 2 Parts Exploded View Door 83 82 69 70 73 72 74 75 76 79 80 81 84 85 85 86 87 88 89 90 91 92 93 84 71 68 For NR BW414MN SS NR BW414VS XN For NR BW464VS XN 77 78 For BW414SSWG AE SWWG AE 94 ...

Страница 29: ...w Packing PAPER PROTECTOR FRONT ONLY HONG KONG MODEL INDIA MODEL FOR STAINLESS MODEL ALL COUNTRIES HONG KONG MODEL TOP PAD FRONT TOP PAD BACK PACKING BELT STICKER BARCODE FOAM TOP PAD L R PLASTIC COVER BOTTOM TRAY AS PROTECTOR FORM COVER CONTROL ...

Страница 30: ...ONTROL 13 CNRAH 222557 CRISPER 8 CNRAG 153290 DOOR SWITCH 10 CNRBH 139440 S CNRAH 256830 FOR NR BW414MNVN S CNRAH 256870 1 1 1 1 1 1 1 1 FOR NR BW414SSMY FOR NR BW414SSHK S CNRAH 256820 FOR NR BW414SS1N S CNRAH 256850 FOR NR BW414SS2N S CNRAH 300280 FOR NR BW414SSVN S CNRAH 256860 FOR NR BW414SSWA S CNRAH 256890 FOR NR BW414SSWG S CNRBH 139270 FOR NR BW414SSAE S CNRBH 139290 1 FOR NR BW414SNMY S C...

Страница 31: ...OOLING NOT ENOUGH ICE FORMING BIG HANDLE 1 1 1 1 S CNRBG 169231 SUPPLY CORD AS S3P 35 CNRAF 167314 INS COVER COIL F 28 1 1 1 1 1 1 1 1 CNRAF 175211 COVER COIL 29 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 CNRBH 135250 ICE CUBE TRAY AS 37 1 1 1 1 1 1 1 1 CNRAH 229894 HOLDER ICE TRAY 36 1 1 1 1 1 1 1 1 CNRAH 227460 BOX ICE TRAY 38 1 1 1 1 1 1 1 1 CNRAH 222547 CASE FC BOTTOM 40 1 1 1 1 1 1 1 1 CNRAC 206012 HANG...

Страница 32: ...SSOR DG77C14RAW5 CNR91 145590 COMPRESSOR DHS73C10RAW CNRAB 116580 COMPRESSOR EFI100E13DGH 54 1 1 1 1 CNRAG 164560 BOX CAPACITOR 48 FOR NR BW414SS1N 2N 1 CNRBG 172356 FOR NR BW414SSVN WA MNVN 1 1 CNRBG 172346 FOR NR BW414SSWG SWWG FOR NR BW414SSHK VN WA WG AE MNHK VN SWWG AE FOR NR BW414SSMY 1N 2N MNMY SNMY 1 1 CNRBG 173596 LANGUAGE ENGLISH 1 1 1 S S S S S CNRAH 239732 WARNING LABEL ENG 44 1 1 1 1 ...

Страница 33: ... 320324 COVER CONTROL SL FOR NR BW414VSPH 1N 2N MY VN WA 1 CNRAD 320203 COVER CONTROL SL FOR NR BW464VSMY HK 1N VN WA PH 1 CNRAD 326470 COVER CONTROL ST FOR NR BW464XNMY HK SG VN 1 CNRAD 326480 COVER CONTROL ST FOR NR BW414XNMY SG VN 1 CNRAD 327640 COVER CONTROL ST CNRAE 136513 LATCH DOOR 84 1 1 1 1 1 1 1 1 CNRAD 305832 STOPPER DOOR 85 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CNRAD 290823 GASKET DOOR FC 86 1 1...

Страница 34: ...64VSVN 1 CNRBK 115950 FOR NR BW464VSWA 1 CNRBK 115970 FOR NR BW464VSPH 1 CNRBK 115980 FOR NR BW464XNMY 1 CNRBK 115770 FOR NR BW464XNHK 1 CNRBK 115790 FOR NR BW464XNSG 1 CNRBK 115800 FOR NR BW464XNVN FOR NR BW414SSHK 1N 2N MNHK VN MY VS1N NR BW464VS1N VSHK XNHK 1 CNRBK 115960 FOR NR BW464VSMY 1 CNRBK 115760 PACKING AS CNRBK 119710 BOTTOM TRAY AS 1 1 1 1 1 1 1 CNRAJ 162090 PLASTIC COVER 1 1 1 1 1 1 ...

Страница 35: ... TECHNICAL INFORMATION FOR COUNTERMEASURE COOLING NOT ENOUGH ICE FORMING OF NON INVERTER INVERTER 2 31 32 ADD COUNTERMEASURE KIT FOR REPAIR COOLING NOT ENOUGH ICE FORMING 2 2 28 REVISE RUNNING PAGE NO REVISE FROM P 2 26 TO P 2 28 3 4 ADD DETAIL SPEC OF NEW MODEL ADD MODEL NO BW414SS2N NR BW414SNMY 4 23 27 ADD AND REVISE PART NAME NO FOR NEW MODELS AND UPDATE PARTS 2 4 ADD MODEL NR BW464VS1D BW464X...