9
Built-in functions are determining the beginning and end. Status beginning of leave shall be determined at the beginning of each
subsequent 24-hour segment. Status of the end of the leave, after identification of the status of the beginning of the current leave
notes. Start date to determine when in the last 24 hours, the segment did not have any door openers. When it is determined the sta-
tus of the start of leave, in the current 24-hour segment carries out the normal regulation of stored pattern for the adaptive control is
no longer observed. At the end of the leave is determined by first opening the door. When it is determined the status of the end of
the leave starts immediately implement adaptive control in accordance with the stored pattern.
If the current 24-hour segment no records for adaptive control is the basis for adaptive control using recorded pattern of the last 24
hour segment. This is a situation when you connect the appliance to the network voltage or when they return from leave, when in
this segment of last week was not recorded opening the door.
3.4.
Super Cool Mode
Logic board
Intensive freezing function is switched on by pressing the key "A" until the symbol "C" lights up.
The function of intensive freezing means the operation of the appliance at s1 °C for 50 hours.
Afterwards the regulation returns back to the temperature set before the intensive freezing function has been switched on. After the
expiration of the function (after 50 hours), defrosting of the appliance begins.
Compressor operation counter resets. In case the function is interrupted earlier, defrosting does not occur and compressor opera-
tion counter does not reset.
Содержание NR-BD31EX1
Страница 2: ...2 1 Safety Precautions ...
Страница 3: ...3 ...
Страница 4: ...4 ...
Страница 6: ...6 Name Plate ...
Страница 10: ...10 4 Location of Controls and Components 4 1 Control Panel 4 2 Components ...
Страница 11: ...11 5 Installation Instructions ...
Страница 12: ...12 ...
Страница 13: ...13 6 Operating Instructions 6 1 Setting the temperature ...
Страница 17: ...17 7 2 Measuring points 7 3 Value of Temperature sensors ...
Страница 19: ...19 8 Troubleshooting Guide 8 1 Not cooling at all Both PC FC Compressor does not operate ...
Страница 20: ...20 8 2 PC FC is not cooling Compressor operates ...
Страница 21: ...21 8 3 Cooling system trouble ...
Страница 22: ...22 8 4 Temperature sensor trouble ...