3 Technical Descriptions

3.1.

Connecting of the appliance and management

When you first start the machine the temperature must be set to a setting at +5 °C. After the refrigerator is plugged in, it begins to
operate in accordance with the conditions of temperature regulation. In the case that the power-on temperature sensor on the evap-
orator of the cooling part of less than +10 °C, the compressor is blocked for a minimum off time of the compressor, which is 5 min-
utes. 

Operation

Logic board display

Adjustment and display of temperatures of the cooling / freezer:

By pressing the "A" round temperature is set from left to right. Each time you press, the setting moves one step. On module 6 LEDs,
which signaled the set temperature and the function of intense freezing. LED1 representing setting intense freezing, LED2 repre-
senting s1 °C, LED3 +3 °C and that when further to LED6, which represents a last adju9 °C.
The first time you press the button, starts with a frequency of 1 Hz flashes last temperature setting. The next time we move one step
and starts flashing the new temperature setting. After 3 seconds, the new setting is saved and the flashing stops.
Function of intense freezing incorporated by pressing "A" repeatedly to light up the symbol "C". After 50 hours, the function is auto-
matically terminated and the setting returns to the last selected setting that was before activating the intense freezing. Feature
intense freezing can also prematurely terminated if another setting is selected.

3.2.

Purpose of regulation, input parameters and controlled outputs

Purpose of regulation

Basic functionality of the appliance

The purpose of the electronics can be divided into several completed jobs:

• Assurance of the set temperature in cooling compartment
• Melting ice in the cooling compartment

Set temperature in cooling compartment is adjustable in increments of temperature, 1, +3, +5, +7, +9 °C. Supported func-
tion is intense freezing food (Super Cool Mode).

Input parameters

1. The measured temperature at the sensor of the cooling space.
2. The measured temperature at the sensor of the evaporator of the cooling space
3. Magnetic switches on doors and refrigeration space
4. Settings through the control module

Controlled outputs

1. Compressor
2. Fan
3. Cooling compartment illumination
5. Display

Содержание NR-BD31EX1

Страница 1: ...ainless S Inox look W White Destination E Europe Continental TABLE OF CONTENTS PAGE PAGE 1 Safety Precautions 2 2 Specifications 5 3 Technical Descriptions 7 4 Location of Controls and Components 10 5 Installation Instructions 11 6 Operating Instructions 13 7 Service Mode 14 8 Troubleshooting Guide 19 9 Disassembly and Assembly Instructions 23 10 Schematic Diagram 30 11 Exploded View and Replaceme...

Страница 2: ...2 1 Safety Precautions ...

Страница 3: ...3 ...

Страница 4: ...4 ...

Страница 5: ...C B57020 M2502 EPCOS Freezer compartment sensor FCC B57020 M2502 EPCOS Ambient temperature sensor ATC N A Defrost temperature sensor DFC B57020 M2502 EPCOS Compressor Model Jiaxipera NE1111Y Rotation speed 2940 rpm Curled resistance cord at 25 C Main wiring 27 88 Auxiliary wiring 22 65 Overlord relay Model B40 105 Operating temperature without power 105 5 C Return temperature 61 9 C Operating curr...

Страница 6: ...6 Name Plate ...

Страница 7: ...p and starts flashing the new temperature setting After 3 seconds the new setting is saved and the flashing stops Function of intense freezing incorporated by pressing A repeatedly to light up the symbol C After 50 hours the function is auto matically terminated and the setting returns to the last selected setting that was before activating the intense freezing Feature intense freezing can also pr...

Страница 8: ...erformance monitoring apparatus in a given time cycle adapted to the opera tion of the apparatus so that the temperature of the food despite the opening of doors and loading new food does not rise above the optimum temperature for cooling Adaptive cooling is only permitted when setting 16 C The function of the adaptive cooling appa ratus provides intensive cooling space before the expected intensi...

Страница 9: ...h the stored pattern If the current 24 hour segment no records for adaptive control is the basis for adaptive control using recorded pattern of the last 24 hour segment This is a situation when you connect the appliance to the network voltage or when they return from leave when in this segment of last week was not recorded opening the door 3 4 Super Cool Mode Logic board Intensive freezing functio...

Страница 10: ...10 4 Location of Controls and Components 4 1 Control Panel 4 2 Components ...

Страница 11: ...11 5 Installation Instructions ...

Страница 12: ...12 ...

Страница 13: ...13 6 Operating Instructions 6 1 Setting the temperature ...

Страница 14: ...s arbitrarily switched The machine runs again in response to the previous settings when the service mode is canceled 7 1 1 How to start Service mode starts when the temperature setting button is twice pressed for 5 seconds After the first 5 seconds press last temperature setting LED indicator flashes once After the second 5 seconds press all temperature setting LED indicators starts blinking with ...

Страница 15: ... indicator circularly moves from left to right in response to a short press of temperature setting button Each LED indicator represents the state of input or output I O for each service mode LED indicator is ON if I O is ON LED indicator is blinking if I O is OFF State of selected I O is changed by pressing the temperature setting button for 3 seconds In case of the magnetic door sensor failure in...

Страница 16: ...6 7 1 4 Error Display in Normal Operation Mode In case of refrigerator compartment temperature sensor failure all LED indicators blink once and then they are off for 5 seconds It repeats after 5 seconds ...

Страница 17: ...17 7 2 Measuring points 7 3 Value of Temperature sensors ...

Страница 18: ...nejne for 5 seconds after which the rate again In the event of failure of the cooling space sensor is installed timing algorithm which raises and delete request for cooling of the cooling space to activate or deactivate the compressor 15 minutes ON 30 minutes OFF then the fan is not operating Function intense freezing SF is in the case of cancellation of the sensor of the cooling space is blocked ...

Страница 19: ...19 8 Troubleshooting Guide 8 1 Not cooling at all Both PC FC Compressor does not operate ...

Страница 20: ...20 8 2 PC FC is not cooling Compressor operates ...

Страница 21: ...21 8 3 Cooling system trouble ...

Страница 22: ...22 8 4 Temperature sensor trouble ...

Страница 23: ...e LED Cover to the left 3 Remove LED Lamp Assy and disconnect the connector 4 LED Lamp Assy 9 2 Main PCB 1 Main PCB is installed in the upper side of the refrigerator 2 Slide both of Head Panel Cover Sides to remove 3 Unscrew the two screws fixing the Head Panel Cover Center and remove it 4 Disconnect the 4 connectors 5 Main PCB Assy ...

Страница 24: ...24 9 3 Fan Assy 1 Unhook two hooks above the Fan Assy Cover by insert ing the screwdriver and remove it 2 Unscrew the Fan Assy 3 Disconnect the connectors 4 Fan Assy ...

Страница 25: ...he sensor cover is hooked at two position as shown in the photo 3 Cut off the damages sensor at the base of sensor head 4 Strip off approx 25mm of additional cable insulation and 5mm of basic insulation of the conductor 5 First crimp the enclosed end splices on conductor of the new sensor Place the enclosed thermo shrinkable bushing Crimp end splices on conductors of cut cable ...

Страница 26: ...26 6 Use hair dryer and heat the bushings so that they tightly wrap the conductors and prevent moisture from breaking through the joint 7 Place the sensor into its seat and replace the sensor cover ...

Страница 27: ...r 2 Unscrew the screws fixing the Upper Hinge 3 Replace the Door Bushing and the Door Plug PC 4 Remove the Door PC 5 Remove the Hinge Cover VC 6 Unscrew the screws fixing the Middle Hinge and remove the Middle Hinge 7 Remove the Door FC 8 Remove the Middle Hinge Plugs and the Screw Cap then unscrew the screw ...

Страница 28: ... condenser 11 Replace the Leveling Leg Right with the Lower Hinge and the Leveling Leg Left Then rise the appliance 12 Replace the Door Bushing and the Door Plug FC 13 Assemble the Door FC 14 Replace the Door Bushing and the Door Plug FC 15 Turn the Middle Hinge upside down and screw it Put the thick washer above the Middle Hinge 16 Assemble the Door PC ...

Страница 29: ...w the screws fixing the Upper Hinge 18 Install the Hinge Cover 19 Install the Hinge Cover VC 20 Remove the Filling Plugs 21 Unscrew the Handles 22 Screw the Handles on the right side 23 Install the Filling Plugs ...

Отзывы: