22
8.3.
Display sign list
Summary of Error Codes
SENSOR
TEMPERATURE
USER MODE REACTION
SERVICE MODE REACTION
(1) Freezer (FCC)
> +50
°
C or < -50
°
C
(sensor is short or open)
Display Sr (blinks) in FC number
segment
Sr Symbol blinks
Set PC segment OFF till error is
finished.
Display FE 01
(2) Refrigerator (PCC)
> +50
°
C or < -50
°
C
(sensor is short or open)
Display FE 02
(3) Defrost (DFC)
Short (< 100
Ω
) or < -50
°
C
Display FE 03
(4) AT sensor (ATC)
Short or < -30
°
C
Display FE 04
Breakdown of (1) and (2)
Display FE 12
Breakdown of (1) and (3)
Display FE 13
Breakdown of (1) and (4)
Display FE 14
Breakdown of (2) and (3)
Display FE 23
Breakdown of (2) and (4)
Display FE 24
Breakdown of (3) and (4)
Display FE 34
Breakdown of (2) and (3) and (4)
Display FH 01
Breakdown of (1) and (3) and (4)
Display FH 02
Breakdown of (1) and (2) and (4)
Display FH 03
Breakdown of (1) and (2) and (3)
Display FH 04
Breakdown of all sensors
Display FU 00
DEFECT TYPE
DETAILS
USER MODE REACTION
SERVICE MODE REACTION
Compressor Defect
DFC sensor temp > -10
°
C
(DFC sensor temp.unchanges for
10 min.continuous compressor run)
Display Sr (blinks) in FC temperature
display and Set PC temperature
display OFF till error is finished.
Display FO 05
Defrost Heater Defect
DFC sensor < 0
°
C
Display FO 06
DEFECT TYPE
DETAILS
USER MODE REACTION
SERVICE MODE REACTION
Low Voltage
Power supply < 170V
FC temperature display shows LO
RC temperature display
Display LO PO
ERROR
DETAILS
USER MODE REACTION
SERVICE MODE REACTION
FCC sensor > -10
°
C
FC is not cool enough
FC temperature display LF blinks till
error finishes
Display CO 01
PCC sensor > +20
°
C and if
Holiday mode is not active
PC compartment is warm
PC temperature display LC blinks till
error finishe
Display CO 02
PCC sensor < -5
°
C
PC is too cool
PC temperature display HC blinks till
error finishes
Display CO 03
FCC sensor > -10
°
C and
PCC sensor > +20
°
C and if
Holiday mode is not active
FC and PC both are not cool
enough
FC temperature display LF blinks and
PC number segment LC blinks
Display CO 04
USER MODE REACTION
SERVICE MODE REACTION
Compressor Defect
Sr
FO 05
Defrost Heater Defect
Sr
FO 06
Sensor Defect (Short-Open)
Sr
F* **
FCC sensor > -10
°
C and
PCC sensor > +20
°
C
LF and LC
CO 04
FCC sensor > -10
°
C
LF
CO 01
PCC sensor > +20
°
C
LC
CO 02
PCC sensor > -5
°
C
HC
CO 03
Содержание NR-B29SG2
Страница 2: ...2 1 Safety Precautions ...
Страница 3: ...3 ...
Страница 4: ...4 ...
Страница 7: ...7 3 General Introduction 3 1 Flow of Refrigerant ...
Страница 8: ...8 3 2 Flow of Air 3 2 1 Inside the Fridge 3 2 2 Flow of Air Through Air Ducts Front view ...
Страница 12: ...12 5 Location of Controls and Components 5 1 Display and Control Panel ...
Страница 13: ...13 5 2 Components ...
Страница 23: ...23 9 Troubleshooting Guide 9 1 Not cooling at all Both PC FC compressor does not operate ...
Страница 24: ...24 9 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Страница 25: ...25 9 3 FC is not cooling Compressor operate ...
Страница 26: ...26 9 4 Cooling system trouble ...
Страница 27: ...27 9 5 Temperature sensor trouble ...
Страница 28: ...28 9 6 Temperature sensor trouble ...
Страница 35: ...35 2 Remove PC bottom multiflow caps 4 and unscrew the screws 5 ...
Страница 41: ...41 How to replace fan motor Summary ...
Страница 78: ...78 12 Dimensions ...
Страница 79: ...79 13 Schematic Diagram ...
Страница 80: ...80 14 Exploded View and Replacement Parts List 14 1 NR B32SG2 NR B32SW2 14 1 1 Interior Parts ...
Страница 82: ...82 14 1 3 Multiflow Parts ...
Страница 84: ...84 14 1 5 Door Assy Parts ...
Страница 86: ...86 14 1 7 Unit Parts ...
Страница 88: ...88 14 2 NR B29SG2 NR B29SW2 14 2 1 Interior Parts ...
Страница 90: ...90 14 2 3 Multiflow Parts ...
Страница 92: ...92 14 2 5 Door Assy Parts ...
Страница 94: ...94 14 2 7 Unit Parts ...