8.2. Measurement of microwave
output
The output power of the magnetron can be determined by
performing IEC standard test procedures. However,due to the
complexity of IEC test procedures, it is recommended to test
the magnetron using the simple method outlined below.
Necessary Equipment:
*1 liter beaker *Glass thermometer
*Wrist watch or stopwatch
NOTE:
Check the line voltage under load.Low voltage will
lower the magnetron output. Take the temperature
readings and heating time as accurately as possible.
1. Fill the beaker with exactly one liter of tap water.Stir the
water using the thermometer and record the water’s
temperature. (recorded as T1).
2. Place the beaker on the center of oven cavity floor.
Set the oven for High power and heat it for exactly one
minute.
3. Stir the water again and read the temperature of the water.
(recorded as T2).
4. The normal temperature rise at High power level for each
model is as shown in table.
TABLE (1L-1min. test)
RATED OUTPUT
TEMPERATURE RISE
1000W
Min. 15.4°F(8.6°C)
26
NN-CS597S
Содержание NN-CS597S APH
Страница 2: ...2 NN CS597S ...
Страница 3: ...3 NN CS597S ...
Страница 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN CS597S ...
Страница 6: ...3 SCHEMATIC DIAGRAM 3 1 APH 6 NN CS597S ...
Страница 7: ...3 2 CPH 7 NN CS597S ...
Страница 28: ...9 4 At least once a year have the radiation monitor checked for calibration by its manufacturer 28 NN CS597S ...
Страница 34: ...10 6 How to check the semiconductors using an OHM meter 34 NN CS597S ...
Страница 35: ...11 EXPLODED VIEW AND PARTS LIST 11 1 EXPLODED VIEW 35 NN CS597S ...
Страница 41: ...12 DIGITAL PROGRAMMER CIRCUIT 12 1 SCHEMATIC DIAGRAM 41 NN CS597S ...
Страница 42: ...42 NN CS597S 05 07 ChengWei S 8S7 Printed in China ...