- 7 -
NC-TXF22, NC-TXF30
3.4 Failure diagnostics chart
3.4.1 No power. (There is no power indication)
When the above parts are normal
When the above parts are normal
Replace the Control unit A (bottom).
Replace the Control unit B (operation).
Replace the Power cord.
Is there connection in the power cord? (0
Ω)
Power cord
Replace the Thermal fuse comp.
Is there connection across the blue lead wire on the
peg frame?
Thermal fuse comp.
Action
Diagnostics Method
Check
The items in the Check correspond to those shown in Check Point on P. 6.
3.4.2 Water is not boiling. (Water pour out)
Replace the Container comp.
Is there connection across the boiling heater?
(approx. 70
Ω)
(between the brown and the red
portions)
Boiling heater
Replace the Control unit A (bottom).
When the above parts are normal
Action
Diagnostics Method
Check
The items in the Check correspond to those shown in Check Point on P. 6.
4. DISASSEMBLY AND REASSEMBLY INSTRUCTIONS
4.1 Bottom plate and Body
1. Remove 2 tapping screws and 1 truss screw
from bottom plate.
2. Remove 1 screw and sleeve from body.
3. Remove black, white lead wire and earth
wire from peg frame.
4. Remove body off.
FIG. 1
Tapping screw
(M4 x 12)
Truss head screw
Bottom plate
Sleeve
Screw A
Body