System configutration and wiring
Signal
Pin
Symbol
Function
I/F
No.
circuit
Gain
switching
Alarm clear
・The function depends on the value of Pr30.
・No.2 Gain change Funcutions See Protective Adjustments on page 62.
・ If the COM- connection is kept closed for more
than 120 ms, the alarm status will be cleared.
・For details, see Protective Functions on
page 64.
27
31
GAIN
A-CLR
SI
page 38
SI
page 38
Input Signals (Position Control) and their Functions
Signal
Pin
Symbol
Function
I/F
No.
circuit
Command
pulse
Command
sign
Command
pulse scalar
switch
Battery +
Battery ー
・This is the input terminal for command pulses. The driver
receives this signal by a high-speed photo coupler.
・The input impedance of PULSE and SIGN signals is 220 Ω .
・Command pulses can be input in three different
ways. Use Pr42 to select one of the following.
① Quadrature (A and B) input
② CW (PULSE)/CCW (SIGN) pulse input
③ Command pulse (PULS)/Sign (SIGN) input
・With COM- closed, the numerator of the command
scalar is changed from the value stored in Pr46
(Numerator of 1st Command Scalar) to the value
stored in Pr47 (Numerator of 2nd Command Scalar).
< Note >
Don't enter command pulses 10 ms after
or before switching.
・Connect a backup battery for absolute
encoder (pole-sensitive !).
・If the battery is connected directly to the driver, it is
not necessary to connect a battery to this terminal.
3
4
5
6
28
44
45
PULS1
PULS2
SIGN1
SIGN2
DIV
BATT +
BATT −
PI
page 38
SI
page 38
――
Pr30 value
0
1
Connection
to COM-
Open
Close
Open
Close
Function
Velocity loop: PI operation
Velocity loop: P operation
・1st gain selected (Pr10, 11, 12, 13 and 14)
・2nd gain selected (Pr18, 19, 1A, 1B, 1C)