28
−
Receptacle on the
driver side
10250-52A2JL
Connector to controller side
Part description
Solder type plug
Shell
Part No.
10150-3000VE
10350-52A0-008
Manufacturer
by Sumitomo 3M
List of Available Components
CN I/F Connector (For Controller)
Wiring Instructions
Displace the peripheral devices such as
the controller max. 3 m away from the
driver.
● CN I/F Connector Specifications
・The CN I/F pins assignment is shown in "Optional Parts" in Appendix.
ID
MODE
IM
SER
IN
SER
OUT
I/F
SIG
U
V
W
L 1
L 2
L 3
B 1
B 2
r
t
P
SP
G
SET
制御
装置
3m以内
30cm以上
COM+
GND
1
GND
アナログ
GND
CN I/F
COM-
FG
VDC
電源部
モータ
o
p
2
Separate these wiring min. 30 cm from
the main circuit wires. Don't lay these
wires in the same duct of the
mains or bundle with them.
The control power (VDC) between COM+ and
COM- should be supplied by the customer
(recommended voltage: +12VDC to +24VDC).
Control signal output terminals can accept
max. 24V or 50mA: Don't apply larger voltage
or current exceeding these limits.
If you directly activate a relay using the control
signal, install a diode in parallel to the relay as
shown in the left figure. Without a diode or with
it but placed in the opposite direction, the driver
will be damaged.
Use a shielded twist-paired type for the
wiring of pulse input, encoder signal
output or analog command input.
The Frame Ground (FG) is connected to
an earth terminal in the driver.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com