5. Return the Nozzle so that the front is up, and remove the

Floor Nozzle Upper Assy.

*When separating, be careful not to cause whitening 

or damage of the tab fitting hooks of the Floor Nozzle 

Upper Assy.

4.8.

Removal of the Nozzle Motor
Unit

1. Remove the connector of the Nozzle Motor Unit that is

inserted in the P.C.B. E Unit, then remove the Nozzle
Motor Unit and the Belt.

*When assembling, be sure to place the lead wires in 

their original positions. (See the wiring diagram)

4.9.

Removal of the Nozzle Wand
Unit 

1. Remove the connector of the Nozzle Wand Unit that is

inserted in the P.C.B. E Unit, then remove the Nozzle
Wand Unit. 

*When assembling, be sure to place the lead wires in 

their original positions. (See the wiring diagram) 

4.10. Removal of the Lead Wire G

Unit

1. Remove the connector of the Lead Wire G Unit that is

inserted in the P.C.B. E Unit, then remove the Lead Wire
G Unit and the Switch Support.

*When assembling, be sure to place the lead wires in 

their original positions. (See the wiring diagram) 

Содержание MC-UL710-WP47

Страница 1: ... 4 Disassembly and Assembly Instructions 7 4 1 Disassembly of the Body 7 4 2 Replacement of the Fan Motor Unit 9 4 3 Removal of the Nozzle Holder Unit 11 4 4 Removal of the Switches 12 4 5 Replacement of the Cord Set 13 4 6 Removal of the Handle Supporter Unit 14 4 7 Disassembly of the Nozzle Assy 14 4 8 Removal of the Nozzle Motor Unit 15 4 9 Removal of the Nozzle Wand Unit 15 4 10 Removal of the...

Страница 2: ...2 1 Specifications ...

Страница 3: ...3 2 Location of Controls and Components ...

Страница 4: ...nce guide Inspection code Inspection part Inspection method Remedy A Switch Check the continuity of the switch with Switch turned on If there is no continuity replace the Switch To check continuity remove the Gasket V from the terminals After checking fit new Gasket V AMC56L 1800P When replacing the Switch fit the Gasket V as shown in the figure to the left ...

Страница 5: ...remove the Gasket V from the terminals After checking fit new Gasket V AMC56L 1800P D Dust Compartment Unit Filters Dispose of the dust in the Dust Compartment Unit Clean each of the Filters Clean or replace Filter Unit Dust Compartment Filter Kit E Hose Unit Nozzle Assy Check for deformation cracking and blockage of the Hose Unit Check for blockage of the Nozzle Assy Replace the Hose Unit Remove ...

Страница 6: ... unit and preventing further operation H Nozzle Wand Unit Insert the connector of the Nozzle Wand Unit into the P C B E Unit and check the continuity between the following terminals with the pipe portion down Terminal C Terminal E Terminal D Terminal F Replace the Nozzle Wand Unit Inspection code Inspection part Inspection method Remedy ...

Страница 7: ...at least 5MΩ when a direct current of 500V is applied between the power plug terminals and the exterior of the motor Dielectric strength Must be able to withstand 1250V of alternating current applied between the power plug terminals and the exterior of the motor for one minute 4 Do not make changes to models components or materials during repairs and services 5 If a wiring unit has been supplied a...

Страница 8: ... Unit 4 Press the Handle Lever and pull off the Handle Unit 5 Remove the 2 screws of the Upper Body and the Front Body 6 Lift up the Suction Inlet Unit a little then bring it down to the rear and remove it 7 Remove the 2 screws of the Handle then pull both ends of the Handle out to the side and remove it ...

Страница 9: ...the Rear Body Unit 10 Remove the Body Plate Unit 4 2 Replacement of the Fan Motor Unit 1 Refer to the Disassembly of the Body page and disas semble the Body 2 Remove the screw 3 Hold the Motor Case Set and the Curved Pipe Unit and remove them Be careful not to pull on the lead wire and break it ...

Страница 10: ...ar 6 Remove the Faston terminal of the Fan Motor Unit and then remove the Noise Suppressor Unit Hold down the lock and remove After attaching the Faston terminal wrap with Gasket V When assembling place the capacitor thermal protector and wire connector of the various lead wires in their origi nal positions After engaging the Motor Case Set and the Curved Pipe Unit stick Gasket S and the Packing U...

Страница 11: ...rts 3 Insert a flathead screwdriver into the Tab Portions two at the front left and right and one at the rear right located between the Upper Body and the Front Body and remove the Upper Body 4 Remove the Front Body and the Exhaust Unit from the Rear Body Unit When assembling the Exhaust Unit place it aligned at the position of the diagram 5 Remove the 2 screws that attach the Nozzle Holder Unit ...

Страница 12: ...er Unit 4 4 Removal of the Switches 1 Refer to the Disassembly of the Body page and disas semble the Body 2 Refer to the Replacement of the Fan Motor Unit page and remove the motor related parts 3 Refer to the Removal of the Nozzle Holder Unit page and remove the Nozzle Holder Unit 4 Remove the switches from the Switch Fitting Plate 5 Remove the Faston terminals of the switches Hold down the lock ...

Страница 13: ...age and disas semble the Body 2 Refer to the Replacement of the Fan Motor Unit page and remove the motor related parts 3 Refer to the Replacement of the Nozzle Holder Unit page and remove the Front Body 4 Remove the screw 5 Release the Tab Portion between the Wire Bushing and the Cord Retainer and remove the Wire Bushing Next pull out the Cord Set from the Cord Retainer When assembling orient the ...

Страница 14: ...Holder Unit page and remove the Front Body 4 Remove the 3 screws and remove the Handle Supporter Unit 4 7 Disassembly of the Nozzle Assy 1 Release the locks at the 3 places of the diagram 2 Remove the Brush Cover Unit and the Agitator Assy 3 Remove the 4 screws 4 While raising the Tabs in 4 places of the Floor Nozzle Upper Assy that is located on the bottom face of the Noz zle housing the Agitator...

Страница 15: ...place the lead wires in their original positions See the wiring diagram 4 9 Removal of the Nozzle Wand Unit 1 Remove the connector of the Nozzle Wand Unit that is inserted in the P C B E Unit then remove the Nozzle Wand Unit When assembling be sure to place the lead wires in their original positions See the wiring diagram 4 10 Removal of the Lead Wire G Unit 1 Remove the connector of the Lead Wire...

Страница 16: ...16 4 11 Body Wiring Firmly insert the lead wires into the grooves as in the diagram below 4 12 Nozzle Assy Wiring Firmly insert the lead wires into the grooves as in the diagram below ...

Страница 17: ...17 5 Wiring Connection Diagram When replacing the FAN MOTOR UNIT or SWITCHES always cover the tab on connecting terminals with Gasket V after making the connections ...

Страница 18: ...18 6 Exploded View and Replacement Parts List 6 1 EXPLODED VIEW ATTACHMENTS ...

Страница 19: ...MPER 1 A5 AMV73VD2000P LEAD WIRE G UNIT 1 OVERLOAD PROTECTION A6 AMV12ECV000P SWITCH SUPPORT 1 A7 AMV81VD2000P P C B E UNIT 1 A8 AMV13SD200CP NOZZLE MOTOR UNIT 1 A9 AMV28SCV000P BELT 1 A10 AMV97RCV0K0P FLOWER NOZZLE LOWER UNIT 1 A11 XTN4 16BFJ SCREW 4 A12 AMV92RCV0R0P AGITATOR ASSY 1 BEATER BAR A13 AMV98QCV0K0P BRUSH COVER UNIT 1 A14 AMV88R5E020P DUSTING BRUSH UNIT 1 A15 AMV89QD2020P FLOOR NOZZLE ...

Страница 20: ...20 6 3 EXPLODED VIEW BODY UNIT ...

Страница 21: ...0P MOTOR SUPPORT RUBBER FRONT 1 B22 AMV0JPCV000P CURVED PIPE UNIT 1 B23 AMV27ECV000P SWITCH FITTING PLATE 1 B24 AMC01EUF000P SWITCH 2 B25 AMV67VCV000P LEAD WIRE A UNIT 1 B26 AMV99WCV000P FUSE UNIT 1 250V 6 3A B27 AMV68VCV000P LEAD WIRE B UNIT 1 B28 AMV94FCV000P CAPACITOR UNIT 1 B29 AMV70VCV000P LEAD WIRE D UNIT 1 B30 AMV00ED2000P CORD SET 1 MC UL712 B30 AMV00ECV000P CORD SET 1 MC UL710 B31 CE 230V...

Страница 22: ...D20K0P INDIVIDUAL CARTON 1 MC UL712 AMV61ZCV0W0P INDIVIDUAL CARTON 1 MC UL710 AMV01ZCV008P INSTRUCTION BOOK 1 AMV69ZCV000P CUSHION A 1 AMV70ZCV000P CUSHION B 1 AMV0TZCV000P CUSHION C 1 AMV56ZCV000P CUSHION BOTTOM 1 AMV70ACV000P BODY CUSHION 1 AMV10ZCV000P BODY BAG 1 AMV12ZCV000P HANDLE COVER 1 ...