background image

- 7 -

This vacuum cleaner has a thermal cut-out which
automatically trips to protect the vacuum cleaner from
overheating.  If a clog prevents the normal flow of air to the
motor, the thermal cut-out turns the motor off automatically to
allow the motor to cool in order to prevent possible damage to
the vacuum cleaner.

To correct problem: If this occurs, turn the vacuum cleaner
off and unplug the vacuum cleaner from the mains outlet to
allow the vacuum cleaner to cool and the thermal cut-out to
reset.  Check for and remove clogs, if necessary.  Also
check and clean/replace any clogged filters. Wait
approximately forty (40) minutes before switching on the
vacuum cleaner. The motor protector will not reset if the
vacuum cleaner is not disconnected from the mains
socket even if the vacuum cleaner has cooled down.

H) MOTOR PROTECTOR

Motor Protector

This vacuum cleaner has a motor protector by-pass valve
which automatically opens to provide cooling air to the
motor when a clog prevents the normal flow of air to the
motor. If the by-pass valve opens to prevent motor
overheating and possible damage to the vacuum cleaner,
you will notice a change of sound as air rushes through the
valve opening.

To correct problem: See the TROUBLE-SHOOTING
guide.

NOTE:  The motor protector may open when using
attachments or when cleaning new carpet, due to reduced
airflow by the attachments themselves or by new carpet
fluff filling the dust bin quickly.  See the TROUBLE-
SHOOTING guide.

I ) THERMAL CUT-OUT

CAUTION: 

Do not block motor protector.

G) HOW TO USE THE ACCESSORIES

CAUTION:While  using
the accessories, hold the
handle with one hand to
avoid pulling the vacuum
cleaner over.

Lift out accessories needed.

NOTE: After using the accessories, re-insert the hose to the connector pipe.

To avoid accidental injury,
keep children away from the
agitator while in operation.

Connect any of the accessories, as indicated.

1

1

1

2

1

5

1

3

1

4

- 14 -

H) BLOCKAGES

A

B

B

A

Hose Coupling

Suction Inlet

Hose Inlet

Secondary

Filter Screen

The hose located on the vacuum cleaner carries the dirt
from the nozzle up to the dust bin.  If the hose should
become clogged:

Unplug the vacuum cleaner from mains outlet. 

Remove hose coupling and check hose coupling and hose
inlet for clogs according to the following procedure.

To remove hose coupling:

1.Depress and tilt tab as shown.
2.Once tab is clear of the vacuum cleaner inlet, depress

and tilt tab as shown.

To re-install hose coupling: Reverse steps above.

Check suction inlet and secondary filter screen for clogs.

Disconnect nozzle hose from connector pipe, check the
hose. Plug in vacuum cleaner and turn on.

Stretch hose in and out to remove clog. If clogs still exist,
turn the vacuum cleaner over and inspect agitator area for
clogs, see BELT CHANGING AND CLEANING for details.

Connector Pipe

Nozzle

Hose

1

1

1

2

1

5

Connect Mini turbine nozzle as indicated.

To prevent damage to carpeted
floors when using tools the Carpet /
Bare Floor switch should be place
in ‘O’ to turn the agitator OFF. 

I ) HOW TO REMOVE THE TELESCOPIC HANDLE

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

aaaaaaaaaaaaaa

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

bbbbbbbbbbbbbb

With the handle on its lowest position, depress the handle
height adjustment button and raise handle about 6 cm
while turning it counterclockwise. 

You should be able to turn the handle 90° to a transversal
position.

Pull handle straight out until free from vacuum cleaner. Do
not use excessive force.

Handle height

adjust button

1

1

1

2

Содержание MC-UL674

Страница 1: ...with the Australian Standards AS 3350 2 2 1995 and Australian EMC requirements for the C Tick Mark Matsushita Electric Industrial Co Ltd http www panasonic co jp global 2007 Matsushita Electric Industrial Co Ltd All rights Reserved CØ1ZDDEØØEØØ ACØ1ZDDEZØEØ Printed in P R C REMINDER FOR CUSTOMER The model and serial number of the product may be found on the nameplate located at the back of your va...

Страница 2: ...t it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a replacement cover is obtained A replacement fuse cover can be purchased from your local Panasonic Dealer IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY THERE IS A DANGER OF SEVERE ELECTRICAL ...

Страница 3: ...eave the vacuum cleaner plugged into mains socket Unplug from the socket when not in use and before cleaning the appliance or undertaking maintenance operations This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appl...

Страница 4: ...lities are provid ed directly by Panasonic UK Ltd It couldn t be simpler Also available through our Internet is direct shopping for a wide range of finished products take a browse on our web site for further details 17 IDENTIFICATION OF MAIN PARTS HOW TO OPERATE YOUR VACUUM CLEANER A HOW TO ATTACH THE TELESCOPIC HANDLE 4 aaaaaaaaaaaaa aaaaaaaaaaaaa aaaaaaaaaaaaa aaaaaaaaaaaaa aaaaaaaaaaaaa aaaaaaa...

Страница 5: ...ays lift the vacuum cleaner by the carrying handle when transporting to storage Cord clip Handle height adjust button Carrying handle 16 MODEL NO MC UL674 POWER SOURCE 230 240V 50Hz MAX INPUT POWER 2200w MOTOR PROTECTION YES DUST BIN CAPACITY 1 8 litres EXHAUST FILTER HEPA DIMENSIONS W x L x H 368x406x1000 mm NET WEIGHT 11 7 kg DUSTING BRUSH YES PIPE YES CREVICE NOZZLE YES AIR TURBINE YES SPECIFIC...

Страница 6: ...ve dust accumulated or replace the filters filter see DUST BIN FILTER CHANGING AND CLEANING Exhaust filter If exhaust filter is full of dust replace it see EXHAUST FILTER MAINTENANCE Dust bin inlet is blocked If there is a blockage remove it see BLOCKAGES Agitator does not Clogged by a large object in If there is any obstruction remove it rotate the agitator housing Belts broken or loose If the be...

Страница 7: ...avoid accidental injury keep children away from the agitator while in operation Connect any of the accessories as indicated 1 1 1 2 1 5 1 3 1 4 14 H BLOCKAGES A B B A Hose Coupling Suction Inlet Hose Inlet Secondary Filter Screen The hose located on the vacuum cleaner carries the dirt from the nozzle up to the dust bin If the hose should become clogged Unplug the vacuum cleaner from mains outlet R...

Страница 8: ...lean exterior using a clean soft cloth that has been dipped in a solution of mild liquid detergent and water then wrung dry Wipe dry after cleaning DO NOT drip water on vacuum cleaner Wash attachments in warm soapy water rinse and air dry Do not clean in dishwasher DO NOT use accessories if they are wet 8 13 Motor Shaft Belt Pulley 1 4 End Cap Base Slot Agitator Nozzle Base 1 5 TO REPLACE BELT Sea...

Страница 9: ...to the UNLOCK position Grasp back of nozzle cover on each side and lift up to remove it from nozzle 1 1 Belt Agitator 1 2 WARNING Personal Injury Hazard Always unplug the vacuum cleaner before cleaning the brush area as agitator may suddenly restart Failure to do so can result in personal injury Carefully remove any residue that may exist in the belt area TO REMOVE BELT CLEAN AGITATOR Position han...

Страница 10: ...bbbb F EXHAUST FILTER MAINTENANCE 1 1 Exhaust Filter Cover Tab Latch HEPA Exhaust Filter 1 2 Rotate upper dust bin clockwise from the locked position to the unlocked position as shown Separate the upper dust bin from the lower dust bin by lifting it straight off 1 1 1 2 Locking Tabs TO ASSEMBLE THE DUST BIN Align the filter with the locking tabs in the dust bin and push down until you hear a click...

Отзывы: