manualshive.com logo in svg
background image

vax.co.uk

Please read carefully before using this cleaner.

Always fully extend the mains cable before use.

Retain for future reference.

in

st

ru

ct

io

n

m

a

n

u

a

l

Bagless upright vacuum

Centrix 3 series

WARNING:

This cleaner has a constantly

rotating brushbar which, when left in

contact with lino, parquet and other hard flooring
could potentially cause some damage to the floor
surface.

NOTE:

Vax recommends that you raise the height

of the brushbar when using this cleaner on lino
and hard flooring. Vax cannot be held responsible
for damage to these surfaces if the customer fails
to take notice of this recommendation.

!

Vax Careline: (UK) 0844 412 8455

(ROI) 1-800 928 308

Version 1.0

U89-CX3-B-A Centrix 3 UG v1.qxd:v1

8/10/10

14:01  Page 1

Содержание V-020U

Страница 1: ...ft in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using this cleaner o...

Страница 2: ...2 long screws 22 TurboTool Some models only 1 2 14 15 16 10 5 12 13 22 22 17 6 9 3 4 7 8 20 21 WARNING This cleaner has a constantly rotating brushbar which when left in contact with lino parquet and...

Страница 3: ...hot coals cigarette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liqu...

Страница 4: ...irt container push the top in place there will be an audible click when it is secure Fig 3 3 Assembly of the Hose Align the tabs on the lower hose inspection tube with the slots on the hose Push and t...

Страница 5: ...g until the vacuum is comfortable to push The brushbar must reach the carpet for effective cleaning Fig 4 3 IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose an...

Страница 6: ...in place To remove the dirt container press the dirt container release button and lift away from the vacuum cleaner Fig 6 1 Cleaning the HEPA Filter Remove the dirt container lid by grasping the dirt...

Страница 7: ...m cleaner Do not wash in dishwasher 7 Maintenance Cleaning and Changing the Belt TOOLS REQUIRED Crosshead screwdriver WARNING To reduce the risk of electric shock the power cord must be disconnected b...

Страница 8: ...knob Secure parts by screwing in one 1 screw underneath the small wheel flap and the five 5 screws on the underside of the vacuum cleaner 8 Clearing Blockages WARNING To reduce the risk of electric s...

Страница 9: ...properly Solution Review dirt container replacement Cause Dirt container full or blocked Solution Empty dirt container Cause Clogged filters Solution Remove clean and replace filters PROBLEM Accessor...

Страница 10: ...ax Careline or visit vax co uk 10 Consumables To purchase spares and accessories please visit vax co uk HEPA filter kit 1 9 126184 00 Belt kit 1 1 130669 00 11 Technical Specification Voltage 220 240V...

Страница 11: ...11 This page has been left intentionally blank Vax Careline UK 0844 412 8455 ROI 1 800 928 308 U89 CX3 B A Centrix 3 UG v1 qxd v1 8 10 10 14 01 Page 11...

Страница 12: ...ltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your L...

Отзывы: