background image

- 9 -

Lid Release Lever

Dust Bin Lid

1

4

1

5

1

6

C) DUST BIN CLEANING AND REMOVAL

TO REMOVE DUST BIN
Remove dust bin assembly from vacuum cleaner by pressing
the release button as shown.

Remove dust bin from vacuum cleaner tilting it out as shown.

CAUTION: Electrical Shock And Personal Injury Hazard

Always disconnect the vacuum cleaner from mains outlet before carrying out any service or maintenance on the
vacuum cleaner.

Always empty the dust bin when dirt level reaches the “MAX FILL” line.

1

2

1

1

Press the dust bin lid release lever.

Empty wastes into the trash container.

1

3

- 12 -

G) BELT CHANGING AND CLEANING

WARNING: Electrical Shock And Personal Injury Hazard

Disconnect from electrical supply before servicing or cleaning the vacuum cleaner. Failure to do so could result in
electrical shock or personal injury from vacuum cleaner suddenly starting.

Frequently check and remove hair, string and lint build-up in the brush area. If build-up becomes excessive, follow the steps below.
Should the belt become loose or should it break, follow the Belt Removal Instructions.

TO REMOVE NOZZLE COVER

Disconnect from electrical supply. Press foot pedal and tilt the
handle down so the vacuum cleaner is laying flat on the floor.

To protect the floor surface, always place paper under the
nozzle any time the nozzle cover is removed.

Release the nozzle cover by rotating the nozzle cover retainers
to the UNLOCK position and depress tabs to remove. Grasp
back of nozzle cover on each side and lift up to remove it from
nozzle.

Nozzle

Cover

LOCK

UNLO

CK

LOCK

UNLOCK

Nozzle Cover

Retainer

Tab

Tab

1

1

Agitator

Belt

1

2

WARNING: 

Personal Injury Hazard

Always unplug the vacuum cleaner before cleaning the brush area as agitator may suddenly restart.  Failure to
do so can result in personal injury.

Carefully remove any residue that may exist in the belt area.

TO REMOVE BELT/CLEAN AGITATOR

Position hands on the agitator. If the belt is still attached to the
agitator, there will be tension on it.

Carefully lift the right end (belt side) of the agitator and then lift
the left end.

Remove the worn or broken belt from the pulley or motor drive
shaft.

WARNING:

Personal Injury Hazard

Be careful when removing the agitator as the belt
tension is high. Failure to do so could result in
personal injury from the agitator releasing quickly
and snapping away.

Usage

Clean Agitator

HEAVY - every 

week

(used daily)

MODERATE -

every month

(used 2-3 times/week)

LIGHT -

every 2 months

(used 1 time/week)

End

Cap

Cut off any carpet pile, hair or lint
entangled around the agitator and
remove any string or debris located
near the end caps. 

NOTE: In order to keep cleaning efficiency high and to prevent
damage to your vacuum cleaner, the agitator must be cleaned
every time the belt is changed.

1

3

TO EMPTY DUST BIN

Hold dust bin over a trash container.

TO REPLACE DUST BIN
First align base of dust bin with the vacuum cleaner. Then
push dust bin back in place making sure dust bin is securely
latched.

Push the dust bin lid to close the dust bin. 

NOTE: You should hear a noticeable “click” sound when lid
locks in place.

Содержание MC-UL672

Страница 1: ...with the Australian Standards AS 3350 2 2 1995 and Australian EMC requirements for the C Tick Mark Matsushita Electric Industrial Co Ltd http www panasonic co jp global 2007 Matsushita Electric Industrial Co Ltd All rights Reserved CØ1ZDBVØØEØØ ACØ1ZDBVZØEØ Printed in P R C REMINDER FOR CUSTOMER The model and serial number of the product may be found on the nameplate located at the back of your va...

Страница 2: ... it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a replacement cover is obtained A replacement fuse cover can be purchased from your local Panasonic Dealer IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY THERE IS A DANGER OF SEVERE ELECTRICAL S...

Страница 3: ...for use in a garage garden or to suck up liquids Information on Disposal for Users of Waste Electrical Electronic Equipment private households This symbol on the products and or accompanying documents means that used electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take these products to designated collection poi...

Страница 4: ...irect sales at Panasonic UK Order accessory and consumable items for your product with ease and confidence by phoning our Customer Care Centre Monday Thursday 9 00am 5 30pm Friday 9 30am 5 30pm excluding public holidays Or go on line through our Internet Accessory ordering application at www panasonic co uk Most major credit and debit cards accepted All enquiries transactions and distribution faci...

Страница 5: ... the carrying handle when transporting to storage Cord clip Carrying handle Handle height adjust button 16 MODEL NO MC UL672 POWER SOURCE 230 240V 50Hz MAX INPUT POWER 2000w MOTOR PROTECTION YES DUST BIN CAPACITY 1 8 litres EXHAUST FILTER HEPA DIMENSIONS W x L x H 362x397x1000 mm NET WEIGHT 11 0kg DUSTING BRUSH YES PIPE YES CREVICE NOZZLE YES SPECIFICATIONS C HOW TO USE YOUR TELESCOPIC HANDLE B HO...

Страница 6: ...heck dust accumulated on primary Remove dust accumulated or replace the filters filter see DUST BIN FILTER CHANGING AND CLEANING Exhaust filter If exhaust filter is full of dust replace it see EXHAUST FILTER MAINTENANCE Dust bin inlet is blocked If there is a blockage remove it see BLOCKAGES Agitator does not Clogged by a large object in If there is any obstruction remove it rotate the agitator ho...

Страница 7: ...g the vacuum cleaner from mains outlet Remove hose coupling and check hose coupling and hose inlet for clogs according to the following procedure To remove hose coupling 1 Depress and tilt tab A as shown 2 Once tab A is clear of the vacuum cleaner inlet depress and tilt tab B as shown To re install hose coupling Reverse steps above Check suction inlet and secondary filter screen for clogs Disconne...

Страница 8: ...se Slot End Cap Agitator 1 5 TO REPLACE BELT Seat left end of agitator into nozzle base To seat agitator end place rounded portion of agitator end cap down into slot in nozzle base Loop the new belt on the belt pulley Loop the other end of belt onto the belt pulley on the right end of agitator Pull right end of agitator forward and seat it into nozzle base Belt Agitator 1 6 Press firmly checking t...

Страница 9: ...ove Grasp back of nozzle cover on each side and lift up to remove it from nozzle Nozzle Cover LOCK UNLOCK LOCK UNLOCK Nozzle Cover Retainer Tab Tab 1 1 Agitator Belt 1 2 WARNING Personal Injury Hazard Always unplug the vacuum cleaner before cleaning the brush area as agitator may suddenly restart Failure to do so can result in personal injury Carefully remove any residue that may exist in the belt...

Страница 10: ...by gently tapping over a trash container CAUTION Make sure upper dust bin is empty before filter is removed CAUTION Rinse with water only do not use detergent or soap Allow filter to dry 24 hours before putting it back into the dust bin When the cleaning of the filter no longer restores vacuum cleaner suction to full power you need to replace the filter CAUTION When cleaning filter do not use brus...

Отзывы: