3.1. BULB
3.1.1. Bulb Removal
1. Remove Power Nozzle cover (see Belt Removal).
2. Push in and turn bulb counterclockwise, then pull out to
remove.
3.1.2. Bulb Replacement
1. Push in and turn bulb clockwise, to replace. Bulb must not
be higher than 15 Watts(130 Volts).
2. Reinstall Power Nozzle cover (see Belt Replacement)..
3.2. BELT
3.2.1. Belt Removal
1. Remove light cover and light bulb as shown in “Bulb
Removal.”
2. Unscrew the two (2) Power Nozzle cover screws.
3. Turn Power Nozzle upside down.
4. To remove cover, insert screwdriver at cover tabs on both
sides and twist to release tabs.
5. Turn Power Nozzle right side up.
6. Press handle release pedal and lower the swivel.
7. Tilt cover forward from back until front snaps free.
8. Carefully insert and twist screwdriver at each brush support
to free brush from base.
9. Remove worn belt.
3.2.2. Belt Replacement
1. Install new belt in belt groove then over the motor shaft.
2. Place agitator assembly back into Power Nozzle.
3 SERVICE PROCEDURES - POWER NOZZLE
11