Parameter Description
Parameter setting
No. Parameter
name
Adjustment range
Min. unit
Factory setting Check
∗
1
Monitor mode
selection
-
Set frequency
-
Output frequency
-
DC voltage
Output current
-
Feedback frequency
-
Display scale factor
0.1 - 60.0
0.1
1.0
Frequency meter adjustment
-
-
-
Frequency meter full-scale
0 - 400Hz
1Hz
60Hz
FOUT switching
Current analog output
Digital
Analog
Comparative frequency A
0, 0.5
∗
2
- 400Hz
0.01Hz
∗
3
0Hz
Comparative frequency B
0, 0.5
∗
2
- 400Hz
0.01Hz
∗
3
0Hz
Agreement detection width
0 - 400Hz
0.01Hz
∗
3
3Hz
Drop frequency at
instantaneous power failure
0 - 400Hz
0.01Hz
∗
3
3Hz
Free-run time at instantaneous
power failure
1, 2, 3, 4, 5
1
Restart prevention
upon power recovery
Restart
No restart
Retry selection
No retry
-
Retry up to No. of times set
Retry start time
0 - 120 sec
2 sec
4 sec
Frequency setting bias
0 -
−
60Hz
0.01Hz
∗
3
0Hz
Lower limit frequency
0, 0.5
∗
2
to (Upper limit frequency – 0.01) Hz
0.01Hz
∗
3
0Hz
Upper limit frequency
(Lower limit fre 0.01) to 400 Hz
0.01Hz
∗
3
60Hz
Input filter time constant
1, 2, 3, 4, 5
3
Overvoltage trip retry at
power-ON
Trip retry
No retry
Retry
CW rotation
prevention
Enables CW rotation
Prevents CW rotation
Electronic thermal
30 - 150%
5%
115%
∗
1 Parameters marked by
in the Check column are tripped for safety if modified or
memorized.
Cancel the trip before use.
∗
2 The lower limit of the adjustment range varies depending on the [
Starting frequency] setting.
∗
3 When the set value exceeds 160 Hz, the minimum unit of setting is 0.05 Hz.