38
Operations
Web interface operation
View Logs <Monitor>
Indicates the various logs of the unit.
≥
Select or enter the item and then select the “View” button to view.
S.M.A.R.T. <Monitor>
Indicates a replacement recommended component or a replacement mandatory component, if any.
Good: Normal.
Warning: Useful life is about to expire. Replacement is recommended.
Critical: Operation is no longer possible due to malfunction or other causes. Replacement is mandatory.
Log Type
Selects the log type to be displayed.
Standard Trace: View the information history.
Warning Trace: View the warning history.
Error Trace: View the error history.
Total Number Of Entries
Indicates the total number of entries for the selected log.
Start Entry
Input the first entry to display.
Number Of The Line
Input the number of entries per page to display.
HDD
Indicates S.M.A.R.T. information of the HDD in the server connected to the unit.
Information is indicated only for HDDs in recommended servers and HDDs in other
servers that are of the same type as those in recommended servers.
Fan
Indicates information for the fan.
Changer (Magazine Carrier)
Indicates information for the Magazine Carrier.
Changer (Disc Carrier)
Indicates information for the Disc Carrier.
Drive
Indicates information for the drive system.
Power Supply
Monitoring
Indicates the status items below when the “Power Supply Monitoring” setting in the
“Configure” menu is enabled.
“Power Supply Monitoring Unit”/“12V Unit”/“24V Unit”
(Only when an external power supply that supports power supply monitoring
functionality is used)
Magazine
Indicates information for magazines.
≥
When “Warning” is displayed, the slot number and status of the applicable
magazine is displayed below this item.