Included
Accessories
1
2
3
4
5
6
7
8
9
10
11
Date and Time
Buttons LOCK lndication
Alarm lndication-CH1
Alarm lndication-CH2
Maximum Value
Minimum Value
Records Indication
Network Strength (wifi/gprs)
USB Conneted
Battery Indicator
Call Indicator (gsm/gprs)
22
21
20
19
18
17
16
14
13
12
15
ON/OFF
Switch and Log
Alarm Indication
Logging Indication
Records
Humidity Unit
Humidity Value
Temperature Value
Wireless Connection
SMS Indication (gsm/gprs)
Temperature Unit
MAX
MIN
MEM
LOG
CH1
CH3
CH2
CH4
1
9
8
7
6
5
3
4
2
10
11
12
16
17
18
13
14
15
19
20
21
22
LCD
Layout
(
LCD
Working
Temperature
-
30
~
70° C
)
MAX
MIN
MEM
LOG
CH1
CH3
CH2
CH4
R90
Intelligent Data Logger
1
2
6
5
4
3
8
7
9
10
R90
Layout
Button Function
DISPLAY MODES
CD Software/Manuals
Mounting Hardware
USB Cable
USB Pwr Adapter
Left Button
1. Press the left button to check the current readings and historical data
press again to check MAX readings and the capacity.
press once again to check MIN readings and data waiting to upload.
2. Press and hold left button for 3 seconds will turn on/off the LOG function while in unlock mode.
Right Button
1. Press and hold right button for 3 seconds will turn on R90 from off sate.
Press and hold right button for 3 seconds will turn off R90 while in unlock mode.
2. Press right button to turn on/off back light function (optional function for device)
Left & Right Buttons
1. Press left and right buttons together will Lock/Unlock the device.
2. Press and hold left and right buttons for 3 seconds while in unlock mode will delete all data in R90.
HIR90TTW Quick User Guide
External Probe Connectors
Alarm
Indicator
Vent
Buttons (Left/
R
ight)
Model
N
umber
Flip Out
De
s
k
Stand
Wall-
M
ount
ing
Slot
USB port (5V 1A micro 5pin)
SIM
C
ard
S
lot
(
for GSM GPRS
)
A
ntenna
Connector
LCD Area
Specifications
CH-1 CH-2
6
11
1
2
3
4
5
6
7
8
9
10
11
GETTING STARTED
Prerequisite Check Sheet
1. Complete the included form in this PDF to simplify setup.
R90 Unit
1. Attach antenna.
2. Connect probes (power off unit prior to connecting or disconnecting the probes).
3. Connect R90 to computer via USB cable.
4. Note: Fully charge battery prior to logging.
R90 Software Install
1. Unzip TronFlux.zip to C:\
2. Install USB/Com Driver.
Go to C:\TronFlux\Driver folder and run... SETUP.exe
3. Install System Server Software.
Go to C:\TronFlux\Setup.exe
Refer to
“TronFlux User Guide.pdf”
for detailed instructions.
Configure R90
1. Go to C:\TronFlux\LogLive folder and run... LogLive.exe
a) Set wifi (ssid, password).
b) Set IP of PC running software.
c) Assign a logger name.
d) Set Alarm/Alert Min-Max values.
Refer to
“LogLive User Guide.pdf”
for detailed instructions.
Start Logging Service
1. Note: This must be running 24/7 for realtime data collection.
2. Set up Email for Alerts... Click Smtp Server.
a)
Server = your email providers “outgoing smtp address”.
b)
Port = your email providers “port value” check SSL if using.
c) Account = your email address.
d) Password = your password.
Start Management Console
1. Open a Web Browser
2. Enter “localhost” or the PC’s “IP” (that’s running the server) in the address bar.
Refer to
“TronFlux User Guide.pdf”
for detailed instructions.
MEM
LOG
CH1
CH2
Current Readings
Records Recorded
MAX
MEM
LOG
CH1
CH2
MAX
Readings
Record Capacity
MIN
MEM
LOG
CH1
CH2
M
IN
Readings
Record to Upload
C A T A L O G N o .
D E S C R I P T I O N
HIR 9 0 T T W
2 C hannel W ir eless T emp er at ur e D at a Lo g g er
S P E C I F I C A T I O N S
T emp er at ur e R ang e:
- 4 0 ~12 5
A ccur acy:
±0 .5
R eso lut io n:
±0 .1
Pr o b es:
2 Ext er nal
M emo r y C ap acit y:
6 5,0 0 0
Samp le R at e:
1s~2 4 h
PC So f t w ar e:
U SB D r iver , Lo g Live, T r o nF lux W in X P/ 7/ 8 ( 3 2 o r 6 4 b it )
Po w er :
110 V ac t o U SB A d ap t er , R echar g eab le Li- B at t er y
D imensio ns:
14 2 mm×77mm×2 8 mm
N et W eig ht :
18 0 g
Download Software from Thermcoproducts.com
Support \ Downloads \ [ZIP] TronFlux
PLEASE NOTE: This software should be installed on
a dedicated PC running 24/7 , not a office work station.